{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/73098"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/73098","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Optimizing a SiC-based nuclear instrumentation system for molten salt reactors","abstract":"Silicon Carbide based radiation detectors have an exceptional capacity to perform in harsher radiation environments due to favorable thermal properties and stability through high fluences. In combination with the capability to accurately measure thermal and fast neutrons and discriminate from gamma-rays, SiC becomes an obvious candidate for nuclear instrumentation in advanced reactor designs. To effectively put this technology into practice, a detection system will be evaluated against several parameters to ensure an adequate signal is available and detector performance is maintained over a desired lifetime. Weighting factors for detector location, shielding, and size are developed so that the work may be extrapolated to other projects.","abstract_html":"Silicon Carbide based radiation detectors have an exceptional capacity to perform in harsher radiation environments due to favorable thermal properties and stability through high fluences. In combination with the capability to accurately measure thermal and fast neutrons and discriminate from gamma-rays, SiC becomes an obvious candidate for nuclear instrumentation in advanced reactor designs. To effectively put this technology into practice, a detection system will be evaluated against several parameters to ensure an adequate signal is available and detector performance is maintained over a desired lifetime. Weighting factors for detector location, shielding, and size are developed so that the work may be extrapolated to other projects.","abstract_has_math":false,"creators":["Kelly, Kevin"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Petrovic, Bojan"],"committee_chairs":[],"committee_members":["Biegalski, Steven","Kotlyar, Dan"],"year":2023,"date_issued":"2023-08-28","date_published":"2023-08-28","updated_at":"2026-11-19T04:25:27Z","subjects":["Molten Salt Reactor","SCALE","OpenMC","Silicon Carbide Detector","Power Monitoring"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/73098","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/73098","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F73098","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Petrovic, Bojan"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Biegalski, Steven","Kotlyar, Dan"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","George W. Woodruff School of Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Kelly, Kevin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-01-10T18:45:20Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-01-10T18:45:20Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-12"]},{"key":"dc:date.issued","label":"Date","values":["2023-08-28"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2023"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2024-01-10T18:45:21Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["0f37df6e-3498-4ce4-96d4-6df34e533f87"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Nuclear Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","c01ff908-c25f-439b-bf10-a074ed886bb7"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["b2977479-131d-4733-a5d5-cadc72a6fad2"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Molten Salt Reactor","SCALE","OpenMC","Silicon Carbide Detector","Power Monitoring"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/73098"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Silicon Carbide based radiation detectors have an exceptional capacity to perform in harsher radiation environments due to favorable thermal properties and stability through high fluences. In combination with the capability to accurately measure thermal and fast neutrons and discriminate from gamma-rays, SiC becomes an obvious candidate for nuclear instrumentation in advanced reactor designs. To effectively put this technology into practice, a detection system will be evaluated against several parameters to ensure an adequate signal is available and detector performance is maintained over a desired lifetime. Weighting factors for detector location, shielding, and size are developed so that the work may be extrapolated to other projects."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Optimizing a SiC-based nuclear instrumentation system for molten salt reactors"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Petrovic, Bojan"],"dc:contributor.committeemember":["Biegalski, Steven","Kotlyar, Dan"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["College of Engineering","George W. Woodruff School of Mechanical Engineering"],"dc:creator":["Kelly, Kevin"],"dc:date.accessioned":["2024-01-10T18:45:20Z"],"dc:date.available":["2024-01-10T18:45:20Z"],"dc:date.created":["2023-12"],"dc:date.issued":["2023-08-28"],"dc:date.submitted":["December 2023"],"dc:date.updated":["2024-01-10T18:45:21Z"],"dc:description.abstract":["Silicon Carbide based radiation detectors have an exceptional capacity to perform in harsher radiation environments due to favorable thermal properties and stability through high fluences. In combination with the capability to accurately measure thermal and fast neutrons and discriminate from gamma-rays, SiC becomes an obvious candidate for nuclear instrumentation in advanced reactor designs. To effectively put this technology into practice, a detection system will be evaluated against several parameters to ensure an adequate signal is available and detector performance is maintained over a desired lifetime. Weighting factors for detector location, shielding, and size are developed so that the work may be extrapolated to other projects."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/73098"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["0f37df6e-3498-4ce4-96d4-6df34e533f87"],"dc:relation.ispartofseries":["Master of Science in Nuclear Engineering"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","c01ff908-c25f-439b-bf10-a074ed886bb7"],"dc:relation.seriesentity":["b2977479-131d-4733-a5d5-cadc72a6fad2"],"dc:subject":["Molten Salt Reactor","SCALE","OpenMC","Silicon Carbide Detector","Power Monitoring"],"dc:title":["Optimizing a SiC-based nuclear instrumentation system for molten salt reactors"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T04:25:27Z"}