{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/73178"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/73178","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Interlaboratory Comparison of a Complex Targeted Assay: Improving Consistency and Reliability in Metabolomics Analyses","abstract":"Ideal isotope-labeled internal standards for analysis via targeted metabolomics approaches are presented for negative and positive ion modes for both hydrophilic interaction liquid chromatography (HILIC) and reverse phase liquid chromatography (RPLC) chromatography coupled to mass spectrometry. These best performing analytes (BPA) were deduced after experimentation from a collaborative research project involving six top metabolomics research laboratories in the country. These results are detailed in this work, supported by observed behaviors of included chemical classes and chromatographic behaviors, and align with the group hypothesis and expectations","abstract_html":"Ideal isotope-labeled internal standards for analysis via targeted metabolomics approaches are presented for negative and positive ion modes for both hydrophilic interaction liquid chromatography (HILIC) and reverse phase liquid chromatography (RPLC) chromatography coupled to mass spectrometry. These best performing analytes (BPA) were deduced after experimentation from a collaborative research project involving six top metabolomics research laboratories in the country. These results are detailed in this work, supported by observed behaviors of included chemical classes and chromatographic behaviors, and align with the group hypothesis and expectations","abstract_has_math":false,"creators":["Phillips, Emily R."],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Chemistry and Biochemistry","school":null,"contributors":[],"advisors":["Fernández, Facundo M.","Fernandez, Facundo M."],"committee_chairs":[],"committee_members":["Stockton, Amanda M.","Gaul, David"],"year":2023,"date_issued":"2023-12-07","date_published":"2023-12-07","updated_at":"2026-11-19T04:25:27Z","subjects":["Mass spectrometry","chromatography","metabolomics","targeted assay"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/73178","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/73178","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F73178","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Fernández, Facundo M.","Fernandez, Facundo M."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Stockton, Amanda M.","Gaul, David"]},{"key":"dc:contributor.department","label":"Department","values":["Chemistry and Biochemistry"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Sciences","School of Chemistry and Biochemistry"]},{"key":"dc:creator","label":"Author","values":["Phillips, Emily R."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-01-10T18:50:41Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-01-10T18:50:41Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-12"]},{"key":"dc:date.issued","label":"Date","values":["2023-12-07"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2023"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2024-01-10T18:50:42Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["60fbfa01-4d0f-42eb-93b1-7577bf996e40"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Chemistry"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["85042be6-2d68-4e07-b384-e1f908fae48a","f1725b93-3ab8-4c47-a4c3-3596c03d6f1e"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["8954817e-f914-4a18-bccd-8e0ecaf17c10"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mass spectrometry","chromatography","metabolomics","targeted assay"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/73178"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Ideal isotope-labeled internal standards for analysis via targeted metabolomics approaches are presented for negative and positive ion modes for both hydrophilic interaction liquid chromatography (HILIC) and reverse phase liquid chromatography (RPLC) chromatography coupled to mass spectrometry. These best performing analytes (BPA) were deduced after experimentation from a collaborative research project involving six top metabolomics research laboratories in the country. These results are detailed in this work, supported by observed behaviors of included chemical classes and chromatographic behaviors, and align with the group hypothesis and expectations"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Interlaboratory Comparison of a Complex Targeted Assay: Improving Consistency and Reliability in Metabolomics Analyses"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Fernández, Facundo M.","Fernandez, Facundo M."],"dc:contributor.committeemember":["Stockton, Amanda M.","Gaul, David"],"dc:contributor.department":["Chemistry and Biochemistry"],"dc:contributor.other":["College of Sciences","School of Chemistry and Biochemistry"],"dc:creator":["Phillips, Emily R."],"dc:date.accessioned":["2024-01-10T18:50:41Z"],"dc:date.available":["2024-01-10T18:50:41Z"],"dc:date.created":["2023-12"],"dc:date.issued":["2023-12-07"],"dc:date.submitted":["December 2023"],"dc:date.updated":["2024-01-10T18:50:42Z"],"dc:description.abstract":["Ideal isotope-labeled internal standards for analysis via targeted metabolomics approaches are presented for negative and positive ion modes for both hydrophilic interaction liquid chromatography (HILIC) and reverse phase liquid chromatography (RPLC) chromatography coupled to mass spectrometry. These best performing analytes (BPA) were deduced after experimentation from a collaborative research project involving six top metabolomics research laboratories in the country. These results are detailed in this work, supported by observed behaviors of included chemical classes and chromatographic behaviors, and align with the group hypothesis and expectations"],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/73178"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["60fbfa01-4d0f-42eb-93b1-7577bf996e40"],"dc:relation.ispartofseries":["Master of Science in Chemistry"],"dc:relation.orgunit":["85042be6-2d68-4e07-b384-e1f908fae48a","f1725b93-3ab8-4c47-a4c3-3596c03d6f1e"],"dc:relation.seriesentity":["8954817e-f914-4a18-bccd-8e0ecaf17c10"],"dc:subject":["Mass spectrometry","chromatography","metabolomics","targeted assay"],"dc:title":["Interlaboratory Comparison of a Complex Targeted Assay: Improving Consistency and Reliability in Metabolomics Analyses"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T04:25:27Z"}