{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/73187"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/73187","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Mesh extraction from 4D transesophageal echocardiogram for patient-specific digital simulation","abstract":"Mitral valve (MV) regurgitation is a condition resulting from structural, positional, and/or movement abnormalities of the MV. This valvular heart disease (VHD) is characterized by a regurgitant jet into the left atrium (LA) upon contraction of the left ventricle (LV). Because many pathologies may cause the same symptoms of incomplete closure of the MV leaflets, patient-specific diagnostic tools can greatly aid treatment planning. Three-dimensional (3D) transesophageal echocardiogram (TEE), one of the primary diagnostic tools for MV degeneration, can be leveraged beyond an observational imaging platform for patient-specific digital simulation of the MV anatomy. This thesis proposes a computational pipeline aimed at automating the deformation of a single MV mesh across TEE frames of the cardiac cycle. Linear filtering techniques are used to reduce noise and segment the anatomy within each volumetric frame to create a mesh representation of the cardiac anatomy. Two algorithms are compared for mesh deformation across frames in a TEE series: one that employs active surface modeling exclusively, and another which transitions from dense optical flow to active surface modeling. The comparative analysis of these algorithms was conducted using TEE series from 10 different patients. The results indicate a higher efficacy of the composite algorithm. By first deforming the mesh using the general motion of the structures in the image and then snapping the faces of the deforming mesh to the target volume, more accurate deformations were achieved. One of the primary limitations of the algorithm is the dependency on the quality and resolution of 3D TEE data, which can vary significantly across captures. Future improvements are suggested to optimize the automated mesh extraction and preserve the mesh structure during deformation.","abstract_html":"Mitral valve (MV) regurgitation is a condition resulting from structural, positional, and/or movement abnormalities of the MV. This valvular heart disease (VHD) is characterized by a regurgitant jet into the left atrium (LA) upon contraction of the left ventricle (LV). Because many pathologies may cause the same symptoms of incomplete closure of the MV leaflets, patient-specific diagnostic tools can greatly aid treatment planning. Three-dimensional (3D) transesophageal echocardiogram (TEE), one of the primary diagnostic tools for MV degeneration, can be leveraged beyond an observational imaging platform for patient-specific digital simulation of the MV anatomy. This thesis proposes a computational pipeline aimed at automating the deformation of a single MV mesh across TEE frames of the cardiac cycle. Linear filtering techniques are used to reduce noise and segment the anatomy within each volumetric frame to create a mesh representation of the cardiac anatomy. Two algorithms are compared for mesh deformation across frames in a TEE series: one that employs active surface modeling exclusively, and another which transitions from dense optical flow to active surface modeling. The comparative analysis of these algorithms was conducted using TEE series from 10 different patients. The results indicate a higher efficacy of the composite algorithm. By first deforming the mesh using the general motion of the structures in the image and then snapping the faces of the deforming mesh to the target volume, more accurate deformations were achieved. One of the primary limitations of the algorithm is the dependency on the quality and resolution of 3D TEE data, which can vary significantly across captures. Future improvements are suggested to optimize the automated mesh extraction and preserve the mesh structure during deformation.","abstract_has_math":false,"creators":["Gunther, Matthew Joseph"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Dasi, Lakshmi","Anderson, David V."],"committee_chairs":[],"committee_members":["Sangodoyin, Oluwaseun"],"year":2023,"date_issued":"2023-12-08","date_published":"2023-12-08","updated_at":"2026-11-19T03:57:19Z","subjects":["Computer Vision","Bioengineering","Mitral Valve"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/73187","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/73187","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F73187","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Dasi, Lakshmi","Anderson, David V."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Sangodoyin, Oluwaseun"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","School of Electrical and Computer Engineering"]},{"key":"dc:creator","label":"Author","values":["Gunther, Matthew Joseph"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-01-10T18:51:30Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-01-10T18:51:30Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-12"]},{"key":"dc:date.issued","label":"Date","values":["2023-12-08"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2023"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2024-01-10T18:51:31Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["0d6e54bb-b93f-4d4d-9b03-7d1423d593d7","eefeec08-2c7a-4e05-9f4b-7d25059e20a0"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Electrical and Computer Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","5b7adef2-447c-4270-b9fc-846bd76f80f2"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["f8b6e739-0ecd-4831-80cd-4ef4edf0a817"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Computer Vision","Bioengineering","Mitral Valve"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/73187"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Mitral valve (MV) regurgitation is a condition resulting from structural, positional, and/or movement abnormalities of the MV. This valvular heart disease (VHD) is characterized by a regurgitant jet into the left atrium (LA) upon contraction of the left ventricle (LV). Because many pathologies may cause the same symptoms of incomplete closure of the MV leaflets, patient-specific diagnostic tools can greatly aid treatment planning. Three-dimensional (3D) transesophageal echocardiogram (TEE), one of the primary diagnostic tools for MV degeneration, can be leveraged beyond an observational imaging platform for patient-specific digital simulation of the MV anatomy. This thesis proposes a computational pipeline aimed at automating the deformation of a single MV mesh across TEE frames of the cardiac cycle. Linear filtering techniques are used to reduce noise and segment the anatomy within each volumetric frame to create a mesh representation of the cardiac anatomy. Two algorithms are compared for mesh deformation across frames in a TEE series: one that employs active surface modeling exclusively, and another which transitions from dense optical flow to active surface modeling. The comparative analysis of these algorithms was conducted using TEE series from 10 different patients. The results indicate a higher efficacy of the composite algorithm. By first deforming the mesh using the general motion of the structures in the image and then snapping the faces of the deforming mesh to the target volume, more accurate deformations were achieved. One of the primary limitations of the algorithm is the dependency on the quality and resolution of 3D TEE data, which can vary significantly across captures. Future improvements are suggested to optimize the automated mesh extraction and preserve the mesh structure during deformation."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Mesh extraction from 4D transesophageal echocardiogram for patient-specific digital simulation"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Dasi, Lakshmi","Anderson, David V."],"dc:contributor.committeemember":["Sangodoyin, Oluwaseun"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["College of Engineering","School of Electrical and Computer Engineering"],"dc:creator":["Gunther, Matthew Joseph"],"dc:date.accessioned":["2024-01-10T18:51:30Z"],"dc:date.available":["2024-01-10T18:51:30Z"],"dc:date.created":["2023-12"],"dc:date.issued":["2023-12-08"],"dc:date.submitted":["December 2023"],"dc:date.updated":["2024-01-10T18:51:31Z"],"dc:description.abstract":["Mitral valve (MV) regurgitation is a condition resulting from structural, positional, and/or movement abnormalities of the MV. This valvular heart disease (VHD) is characterized by a regurgitant jet into the left atrium (LA) upon contraction of the left ventricle (LV). Because many pathologies may cause the same symptoms of incomplete closure of the MV leaflets, patient-specific diagnostic tools can greatly aid treatment planning. Three-dimensional (3D) transesophageal echocardiogram (TEE), one of the primary diagnostic tools for MV degeneration, can be leveraged beyond an observational imaging platform for patient-specific digital simulation of the MV anatomy. This thesis proposes a computational pipeline aimed at automating the deformation of a single MV mesh across TEE frames of the cardiac cycle. Linear filtering techniques are used to reduce noise and segment the anatomy within each volumetric frame to create a mesh representation of the cardiac anatomy. Two algorithms are compared for mesh deformation across frames in a TEE series: one that employs active surface modeling exclusively, and another which transitions from dense optical flow to active surface modeling. The comparative analysis of these algorithms was conducted using TEE series from 10 different patients. The results indicate a higher efficacy of the composite algorithm. By first deforming the mesh using the general motion of the structures in the image and then snapping the faces of the deforming mesh to the target volume, more accurate deformations were achieved. One of the primary limitations of the algorithm is the dependency on the quality and resolution of 3D TEE data, which can vary significantly across captures. Future improvements are suggested to optimize the automated mesh extraction and preserve the mesh structure during deformation."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/73187"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["0d6e54bb-b93f-4d4d-9b03-7d1423d593d7","eefeec08-2c7a-4e05-9f4b-7d25059e20a0"],"dc:relation.ispartofseries":["Master of Science in Electrical and Computer Engineering"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","5b7adef2-447c-4270-b9fc-846bd76f80f2"],"dc:relation.seriesentity":["f8b6e739-0ecd-4831-80cd-4ef4edf0a817"],"dc:subject":["Computer Vision","Bioengineering","Mitral Valve"],"dc:title":["Mesh extraction from 4D transesophageal echocardiogram for patient-specific digital simulation"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T03:57:19Z"}