{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/75073"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/75073","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Predicting Hemodynamic and Biomechanical Implications of MitraClip Transcatheter Edge-To-Edge Therapy on Treatment of Functional Mitral Regurgitation","abstract":"Mitral regurgitation (MR) is the leading cause of heart valve disease, where moderate MR is present in at least 1.7% of the adult population, increasing to 11.7% in those age 75 years and older. MR occurs when the two leaflets of the mitral valve (MV) do not close properly when they should. Left untreated, MR severity can increase and lead to heart failure. Patients with moderate-to-severe or severe MR who remain symptomatic despite optimal medical therapy and are deemed at high surgical risk by a heart team are candidates for transcatheter edge-to-edge repair with the commercially available MitraClip. Though clinical trials show promising outcomes, challenges with MitraClip use include sufficient reduction of MR while preventing elevated MV pressure gradient (MVG), as these two unfavourable outcomes worsen prognosis. Optimal use and predictive modeling of MVG post-MitraClip is not well defined, especially with four device sizes available in the current G4 generation. Further guidelines to optimize MitraClip usage is needed, as transcatheter MV repair has overtaken surgical repair in the United States. MitraClip use for degenerative MR is well established; however, questions remain for functional MR (FMR). The impact of MitraClip size was first assessed using an excised porcine model, where atrial and ventricular FMR were studied. Residual regurgitation with device size was found to be dependent upon baseline MR conditions, and post-therapy MVG was found to increase most with the largest device size. A parameterization approach was developed to simplify human MV geometries, and MitraClip placement was simulated. Post-MitraClip MVG was found to be greatest for smaller MVs and for larger device size. Forward flow measured by clinical means (CW Doppler) and by engineering means (conservation of mass) showed strong correlation. Applying this in vivo, a post-MitraClip MVG predictive model was developed, which showed good agreement to in vivo FMR outcomes. The outcomes of this thesis can help clinicians assess patient MitraClip candidacy and help optimize MitraClip treatment strategies by predicting post-therapy MVG.","abstract_html":"Mitral regurgitation (MR) is the leading cause of heart valve disease, where moderate MR is present in at least 1.7% of the adult population, increasing to 11.7% in those age 75 years and older. MR occurs when the two leaflets of the mitral valve (MV) do not close properly when they should. Left untreated, MR severity can increase and lead to heart failure. Patients with moderate-to-severe or severe MR who remain symptomatic despite optimal medical therapy and are deemed at high surgical risk by a heart team are candidates for transcatheter edge-to-edge repair with the commercially available MitraClip. Though clinical trials show promising outcomes, challenges with MitraClip use include sufficient reduction of MR while preventing elevated MV pressure gradient (MVG), as these two unfavourable outcomes worsen prognosis. Optimal use and predictive modeling of MVG post-MitraClip is not well defined, especially with four device sizes available in the current G4 generation. Further guidelines to optimize MitraClip usage is needed, as transcatheter MV repair has overtaken surgical repair in the United States. MitraClip use for degenerative MR is well established; however, questions remain for functional MR (FMR). The impact of MitraClip size was first assessed using an excised porcine model, where atrial and ventricular FMR were studied. Residual regurgitation with device size was found to be dependent upon baseline MR conditions, and post-therapy MVG was found to increase most with the largest device size. A parameterization approach was developed to simplify human MV geometries, and MitraClip placement was simulated. Post-MitraClip MVG was found to be greatest for smaller MVs and for larger device size. Forward flow measured by clinical means (CW Doppler) and by engineering means (conservation of mass) showed strong correlation. Applying this in vivo, a post-MitraClip MVG predictive model was developed, which showed good agreement to in vivo FMR outcomes. The outcomes of this thesis can help clinicians assess patient MitraClip candidacy and help optimize MitraClip treatment strategies by predicting post-therapy MVG.","abstract_has_math":false,"creators":["Gooden, Shelley Chee-Mei"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Biomedical Engineering (Joint GT/Emory Department)","school":null,"contributors":[],"advisors":["Dasi, Lakshmi"],"committee_chairs":[],"committee_members":["Yoganathan, Ajit P.","Dixon, Brandon","Vannan, Mani A.","Thourani, Vinod H.","Boudoulas, Konstantinos D."],"year":2023,"date_issued":"2023-03-14","date_published":"2023-03-14","updated_at":"2026-11-19T05:15:25Z","subjects":["Mitral valve","Mitral regurgitation","Functional mitral regurgitation","Hemodynamics","MitraClip","Transcatheter edge-to-edge repair","Mitral repair","Pressure gradient","Predictive model","Echocardiography"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/75073","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/75073","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F75073","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Dasi, Lakshmi"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Yoganathan, Ajit P.","Dixon, Brandon","Vannan, Mani A.","Thourani, Vinod H.","Boudoulas, Konstantinos D."]},{"key":"dc:contributor.department","label":"Department","values":["Biomedical Engineering (Joint GT/Emory Department)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","Wallace H. Coulter Department of Biomedical Engineering"]},{"key":"dc:creator","label":"Author","values":["Gooden, Shelley Chee-Mei"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-05-23T19:12:34Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-05-23T19:12:34Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-05"]},{"key":"dc:date.issued","label":"Date","values":["2023-03-14"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2023"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2024-05-23T19:12:35Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["0d6e54bb-b93f-4d4d-9b03-7d1423d593d7"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Biomedical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","da59be3c-3d0a-41da-91b9-ebe2ecc83b66"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["d85f9f1b-b2b5-4bca-81af-4515c5281e54"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mitral valve","Mitral regurgitation","Functional mitral regurgitation","Hemodynamics","MitraClip","Transcatheter edge-to-edge repair","Mitral repair","Pressure gradient","Predictive model","Echocardiography"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/75073"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Mitral regurgitation (MR) is the leading cause of heart valve disease, where moderate MR is present in at least 1.7% of the adult population, increasing to 11.7% in those age 75 years and older. MR occurs when the two leaflets of the mitral valve (MV) do not close properly when they should. Left untreated, MR severity can increase and lead to heart failure. Patients with moderate-to-severe or severe MR who remain symptomatic despite optimal medical therapy and are deemed at high surgical risk by a heart team are candidates for transcatheter edge-to-edge repair with the commercially available MitraClip. Though clinical trials show promising outcomes, challenges with MitraClip use include sufficient reduction of MR while preventing elevated MV pressure gradient (MVG), as these two unfavourable outcomes worsen prognosis. Optimal use and predictive modeling of MVG post-MitraClip is not well defined, especially with four device sizes available in the current G4 generation. Further guidelines to optimize MitraClip usage is needed, as transcatheter MV repair has overtaken surgical repair in the United States. MitraClip use for degenerative MR is well established; however, questions remain for functional MR (FMR). The impact of MitraClip size was first assessed using an excised porcine model, where atrial and ventricular FMR were studied. Residual regurgitation with device size was found to be dependent upon baseline MR conditions, and post-therapy MVG was found to increase most with the largest device size. A parameterization approach was developed to simplify human MV geometries, and MitraClip placement was simulated. Post-MitraClip MVG was found to be greatest for smaller MVs and for larger device size. Forward flow measured by clinical means (CW Doppler) and by engineering means (conservation of mass) showed strong correlation. Applying this in vivo, a post-MitraClip MVG predictive model was developed, which showed good agreement to in vivo FMR outcomes. The outcomes of this thesis can help clinicians assess patient MitraClip candidacy and help optimize MitraClip treatment strategies by predicting post-therapy MVG."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Predicting Hemodynamic and Biomechanical Implications of MitraClip Transcatheter Edge-To-Edge Therapy on Treatment of Functional Mitral Regurgitation"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Dasi, Lakshmi"],"dc:contributor.committeemember":["Yoganathan, Ajit P.","Dixon, Brandon","Vannan, Mani A.","Thourani, Vinod H.","Boudoulas, Konstantinos D."],"dc:contributor.department":["Biomedical Engineering (Joint GT/Emory Department)"],"dc:contributor.other":["College of Engineering","Wallace H. Coulter Department of Biomedical Engineering"],"dc:creator":["Gooden, Shelley Chee-Mei"],"dc:date.accessioned":["2024-05-23T19:12:34Z"],"dc:date.available":["2024-05-23T19:12:34Z"],"dc:date.created":["2023-05"],"dc:date.issued":["2023-03-14"],"dc:date.submitted":["May 2023"],"dc:date.updated":["2024-05-23T19:12:35Z"],"dc:description.abstract":["Mitral regurgitation (MR) is the leading cause of heart valve disease, where moderate MR is present in at least 1.7% of the adult population, increasing to 11.7% in those age 75 years and older. MR occurs when the two leaflets of the mitral valve (MV) do not close properly when they should. Left untreated, MR severity can increase and lead to heart failure. Patients with moderate-to-severe or severe MR who remain symptomatic despite optimal medical therapy and are deemed at high surgical risk by a heart team are candidates for transcatheter edge-to-edge repair with the commercially available MitraClip. Though clinical trials show promising outcomes, challenges with MitraClip use include sufficient reduction of MR while preventing elevated MV pressure gradient (MVG), as these two unfavourable outcomes worsen prognosis. Optimal use and predictive modeling of MVG post-MitraClip is not well defined, especially with four device sizes available in the current G4 generation. Further guidelines to optimize MitraClip usage is needed, as transcatheter MV repair has overtaken surgical repair in the United States. MitraClip use for degenerative MR is well established; however, questions remain for functional MR (FMR). The impact of MitraClip size was first assessed using an excised porcine model, where atrial and ventricular FMR were studied. Residual regurgitation with device size was found to be dependent upon baseline MR conditions, and post-therapy MVG was found to increase most with the largest device size. A parameterization approach was developed to simplify human MV geometries, and MitraClip placement was simulated. Post-MitraClip MVG was found to be greatest for smaller MVs and for larger device size. Forward flow measured by clinical means (CW Doppler) and by engineering means (conservation of mass) showed strong correlation. Applying this in vivo, a post-MitraClip MVG predictive model was developed, which showed good agreement to in vivo FMR outcomes. The outcomes of this thesis can help clinicians assess patient MitraClip candidacy and help optimize MitraClip treatment strategies by predicting post-therapy MVG."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/75073"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["0d6e54bb-b93f-4d4d-9b03-7d1423d593d7"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Biomedical Engineering"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","da59be3c-3d0a-41da-91b9-ebe2ecc83b66"],"dc:relation.seriesentity":["d85f9f1b-b2b5-4bca-81af-4515c5281e54"],"dc:subject":["Mitral valve","Mitral regurgitation","Functional mitral regurgitation","Hemodynamics","MitraClip","Transcatheter edge-to-edge repair","Mitral repair","Pressure gradient","Predictive model","Echocardiography"],"dc:title":["Predicting Hemodynamic and Biomechanical Implications of MitraClip Transcatheter Edge-To-Edge Therapy on Treatment of Functional Mitral Regurgitation"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T05:15:25Z"}