{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/75103"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/75103","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Comparison of Porosity Detection Methods in Infrared Imaging for Electron Beam Powder Bed Fusion","abstract":"Additive Manufacturing has been seeing widespread adoption in a variety of industries over the years. However, due to the inherent uncertainties with these manufacturing methods, process monitoring and qualification is critical. In situ process monitoring has been seeing significant interest over the years, and, especially in metal powder bed fusion process such as electron beam powder bed fusion, imaging is commonly used to detect defects. This work looks at comparing three basic segmentation methods (manual thresholding, statistical thresholding, and gradient) used for detecting porosity in in situ infrared imaging in electron beam powder bed fusion. Samples were manufactured with a variety of focus offsets to induce porosity, and the segmented infrared images were compared to ex situ X-ray computed tomography scans, which served as a ground-truth reference for objective evaluation. Through this analysis framework, influential parameters for each of the three methods were analyzed for effect on performance in properly detecting porosity, then the three methods were compared to each other.","abstract_html":"Additive Manufacturing has been seeing widespread adoption in a variety of industries over the years. However, due to the inherent uncertainties with these manufacturing methods, process monitoring and qualification is critical. In situ process monitoring has been seeing significant interest over the years, and, especially in metal powder bed fusion process such as electron beam powder bed fusion, imaging is commonly used to detect defects. This work looks at comparing three basic segmentation methods (manual thresholding, statistical thresholding, and gradient) used for detecting porosity in in situ infrared imaging in electron beam powder bed fusion. Samples were manufactured with a variety of focus offsets to induce porosity, and the segmented infrared images were compared to ex situ X-ray computed tomography scans, which served as a ground-truth reference for objective evaluation. Through this analysis framework, influential parameters for each of the three methods were analyzed for effect on performance in properly detecting porosity, then the three methods were compared to each other.","abstract_has_math":false,"creators":["Johnstone, Brian"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Saldana, Christopher","Saldaña, Christopher J.","Fu, Katherine"],"committee_chairs":[],"committee_members":["Kurfess, Thomas"],"year":2023,"date_issued":"2023-04-25","date_published":"2023-04-25","updated_at":"2026-11-19T05:16:01Z","subjects":["Metal additive manufacturing","Electron beam powder bed fusion","Infrared imaging","Segmentation"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/75103","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/75103","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F75103","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Saldana, Christopher","Saldaña, Christopher J.","Fu, Katherine"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Kurfess, Thomas"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","George W. Woodruff School of Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Johnstone, Brian"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-05-23T19:17:56Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-05-23T19:17:56Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-05"]},{"key":"dc:date.issued","label":"Date","values":["2023-04-25"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2023"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2024-05-23T19:17:57Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["6a3b202b-a552-45bf-a034-0b8e33c4a6bb","ebcbc0bb-bdfa-4173-b96f-757ab82cd90c"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Mechanical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","c01ff908-c25f-439b-bf10-a074ed886bb7"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["028ba2d8-6c6e-4f8a-a480-51b555d14e9d"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Metal additive manufacturing","Electron beam powder bed fusion","Infrared imaging","Segmentation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/75103"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Additive Manufacturing has been seeing widespread adoption in a variety of industries over the years. However, due to the inherent uncertainties with these manufacturing methods, process monitoring and qualification is critical. In situ process monitoring has been seeing significant interest over the years, and, especially in metal powder bed fusion process such as electron beam powder bed fusion, imaging is commonly used to detect defects. This work looks at comparing three basic segmentation methods (manual thresholding, statistical thresholding, and gradient) used for detecting porosity in in situ infrared imaging in electron beam powder bed fusion. Samples were manufactured with a variety of focus offsets to induce porosity, and the segmented infrared images were compared to ex situ X-ray computed tomography scans, which served as a ground-truth reference for objective evaluation. Through this analysis framework, influential parameters for each of the three methods were analyzed for effect on performance in properly detecting porosity, then the three methods were compared to each other."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Comparison of Porosity Detection Methods in Infrared Imaging for Electron Beam Powder Bed Fusion"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Saldana, Christopher","Saldaña, Christopher J.","Fu, Katherine"],"dc:contributor.committeemember":["Kurfess, Thomas"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["College of Engineering","George W. Woodruff School of Mechanical Engineering"],"dc:creator":["Johnstone, Brian"],"dc:date.accessioned":["2024-05-23T19:17:56Z"],"dc:date.available":["2024-05-23T19:17:56Z"],"dc:date.created":["2023-05"],"dc:date.issued":["2023-04-25"],"dc:date.submitted":["May 2023"],"dc:date.updated":["2024-05-23T19:17:57Z"],"dc:description.abstract":["Additive Manufacturing has been seeing widespread adoption in a variety of industries over the years. However, due to the inherent uncertainties with these manufacturing methods, process monitoring and qualification is critical. In situ process monitoring has been seeing significant interest over the years, and, especially in metal powder bed fusion process such as electron beam powder bed fusion, imaging is commonly used to detect defects. This work looks at comparing three basic segmentation methods (manual thresholding, statistical thresholding, and gradient) used for detecting porosity in in situ infrared imaging in electron beam powder bed fusion. Samples were manufactured with a variety of focus offsets to induce porosity, and the segmented infrared images were compared to ex situ X-ray computed tomography scans, which served as a ground-truth reference for objective evaluation. Through this analysis framework, influential parameters for each of the three methods were analyzed for effect on performance in properly detecting porosity, then the three methods were compared to each other."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/75103"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["6a3b202b-a552-45bf-a034-0b8e33c4a6bb","ebcbc0bb-bdfa-4173-b96f-757ab82cd90c"],"dc:relation.ispartofseries":["Master of Science in Mechanical Engineering"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","c01ff908-c25f-439b-bf10-a074ed886bb7"],"dc:relation.seriesentity":["028ba2d8-6c6e-4f8a-a480-51b555d14e9d"],"dc:subject":["Metal additive manufacturing","Electron beam powder bed fusion","Infrared imaging","Segmentation"],"dc:title":["Comparison of Porosity Detection Methods in Infrared Imaging for Electron Beam Powder Bed Fusion"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T05:16:01Z"}