{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/75154"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/75154","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Analysis of seismocardiogram signals from healthy and unhealthy subjects using an accelerometer contact microphone","abstract":"Second heart sound (S2) splitting can be used as an indicator for diagnosis of cardiovascular diseases; specifically, paradoxical S2 splitting is an indicator of aortic stenosis. We present that S2 acoustic signatures can be captured accurately from the seismocardiogram (SCG) signals of a sensitive wearable accelerometer contact microphone (ACM) and validated by comparing with digital stethoscope phonocardiogram (PCG) signals. The ACM was placed on the pulmonic region of 18 subjects, 10 with no known heart disease and 8 with known heart disease, for 60 seconds of SCG data collection. ACM signal was first filtered to the appropriate frequency range with a bandpass filter and was segmented to capture just S2 sounds via normalized average Shannon energy and peak detection. Once segmented to S2 sounds, extraction of Smoothed Pseudo Wigner-Ville distribution is used to extract S2 time split and to identify type of S2 splitting. Healthy subjects had SCG S2 time splits range agreeing with S2 time splits from past literature from PCG signals. The ACM SCG signal was also used to identify and capture paradoxical splitting from subjects with known valvular heart diseases such as aortic stenosis, from subjects with mild to severe diagnosis. Validation tests were also conducted on the ACM SCG and showed strong correlation with PCG on the same subjects. In conclusion, a wearable ACM can be used to detect paradoxical splitting in subjects suspected with aortic valvular heart disease and shows high fidelity of capturing S2 time split through SCG signals.","abstract_html":"Second heart sound (S2) splitting can be used as an indicator for diagnosis of cardiovascular diseases; specifically, paradoxical S2 splitting is an indicator of aortic stenosis. We present that S2 acoustic signatures can be captured accurately from the seismocardiogram (SCG) signals of a sensitive wearable accelerometer contact microphone (ACM) and validated by comparing with digital stethoscope phonocardiogram (PCG) signals. The ACM was placed on the pulmonic region of 18 subjects, 10 with no known heart disease and 8 with known heart disease, for 60 seconds of SCG data collection. ACM signal was first filtered to the appropriate frequency range with a bandpass filter and was segmented to capture just S2 sounds via normalized average Shannon energy and peak detection. Once segmented to S2 sounds, extraction of Smoothed Pseudo Wigner-Ville distribution is used to extract S2 time split and to identify type of S2 splitting. Healthy subjects had SCG S2 time splits range agreeing with S2 time splits from past literature from PCG signals. The ACM SCG signal was also used to identify and capture paradoxical splitting from subjects with known valvular heart diseases such as aortic stenosis, from subjects with mild to severe diagnosis. Validation tests were also conducted on the ACM SCG and showed strong correlation with PCG on the same subjects. In conclusion, a wearable ACM can be used to detect paradoxical splitting in subjects suspected with aortic valvular heart disease and shows high fidelity of capturing S2 time split through SCG signals.","abstract_has_math":false,"creators":["Sang, Brian"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Ayazi, Farrokh"],"committee_chairs":[],"committee_members":["Bhatti, Pamela","Anderson, David"],"year":2023,"date_issued":"2023-05-02","date_published":"2023-05-02","updated_at":"2026-11-19T05:05:22Z","subjects":["Aortic Stenosis","Wearable Device","Time Frequency Representation"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/75154","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/75154","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F75154","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ayazi, Farrokh"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Bhatti, Pamela","Anderson, David"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","School of Electrical and Computer Engineering"]},{"key":"dc:creator","label":"Author","values":["Sang, Brian"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-05-23T19:22:24Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-05-23T19:22:24Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-05"]},{"key":"dc:date.issued","label":"Date","values":["2023-05-02"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2023"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2024-05-23T19:22:25Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["298d0abc-b13a-4bb8-a8c5-ba73301c2436"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Electrical and Computer Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","5b7adef2-447c-4270-b9fc-846bd76f80f2"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["f8b6e739-0ecd-4831-80cd-4ef4edf0a817"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Aortic Stenosis","Wearable Device","Time Frequency Representation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/75154"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Second heart sound (S2) splitting can be used as an indicator for diagnosis of cardiovascular diseases; specifically, paradoxical S2 splitting is an indicator of aortic stenosis. We present that S2 acoustic signatures can be captured accurately from the seismocardiogram (SCG) signals of a sensitive wearable accelerometer contact microphone (ACM) and validated by comparing with digital stethoscope phonocardiogram (PCG) signals. The ACM was placed on the pulmonic region of 18 subjects, 10 with no known heart disease and 8 with known heart disease, for 60 seconds of SCG data collection. ACM signal was first filtered to the appropriate frequency range with a bandpass filter and was segmented to capture just S2 sounds via normalized average Shannon energy and peak detection. Once segmented to S2 sounds, extraction of Smoothed Pseudo Wigner-Ville distribution is used to extract S2 time split and to identify type of S2 splitting. Healthy subjects had SCG S2 time splits range agreeing with S2 time splits from past literature from PCG signals. The ACM SCG signal was also used to identify and capture paradoxical splitting from subjects with known valvular heart diseases such as aortic stenosis, from subjects with mild to severe diagnosis. Validation tests were also conducted on the ACM SCG and showed strong correlation with PCG on the same subjects. In conclusion, a wearable ACM can be used to detect paradoxical splitting in subjects suspected with aortic valvular heart disease and shows high fidelity of capturing S2 time split through SCG signals."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Analysis of seismocardiogram signals from healthy and unhealthy subjects using an accelerometer contact microphone"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ayazi, Farrokh"],"dc:contributor.committeemember":["Bhatti, Pamela","Anderson, David"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["College of Engineering","School of Electrical and Computer Engineering"],"dc:creator":["Sang, Brian"],"dc:date.accessioned":["2024-05-23T19:22:24Z"],"dc:date.available":["2024-05-23T19:22:24Z"],"dc:date.created":["2023-05"],"dc:date.issued":["2023-05-02"],"dc:date.submitted":["May 2023"],"dc:date.updated":["2024-05-23T19:22:25Z"],"dc:description.abstract":["Second heart sound (S2) splitting can be used as an indicator for diagnosis of cardiovascular diseases; specifically, paradoxical S2 splitting is an indicator of aortic stenosis. We present that S2 acoustic signatures can be captured accurately from the seismocardiogram (SCG) signals of a sensitive wearable accelerometer contact microphone (ACM) and validated by comparing with digital stethoscope phonocardiogram (PCG) signals. The ACM was placed on the pulmonic region of 18 subjects, 10 with no known heart disease and 8 with known heart disease, for 60 seconds of SCG data collection. ACM signal was first filtered to the appropriate frequency range with a bandpass filter and was segmented to capture just S2 sounds via normalized average Shannon energy and peak detection. Once segmented to S2 sounds, extraction of Smoothed Pseudo Wigner-Ville distribution is used to extract S2 time split and to identify type of S2 splitting. Healthy subjects had SCG S2 time splits range agreeing with S2 time splits from past literature from PCG signals. The ACM SCG signal was also used to identify and capture paradoxical splitting from subjects with known valvular heart diseases such as aortic stenosis, from subjects with mild to severe diagnosis. Validation tests were also conducted on the ACM SCG and showed strong correlation with PCG on the same subjects. In conclusion, a wearable ACM can be used to detect paradoxical splitting in subjects suspected with aortic valvular heart disease and shows high fidelity of capturing S2 time split through SCG signals."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/75154"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["298d0abc-b13a-4bb8-a8c5-ba73301c2436"],"dc:relation.ispartofseries":["Master of Science in Electrical and Computer Engineering"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","5b7adef2-447c-4270-b9fc-846bd76f80f2"],"dc:relation.seriesentity":["f8b6e739-0ecd-4831-80cd-4ef4edf0a817"],"dc:subject":["Aortic Stenosis","Wearable Device","Time Frequency Representation"],"dc:title":["Analysis of seismocardiogram signals from healthy and unhealthy subjects using an accelerometer contact microphone"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T05:05:22Z"}