{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/75546"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/75546","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Exploring The Translational Clinical Value of Cerebrovascular Reactivity Assessments by Diffuse Correlation Spectroscopy","abstract":"Cerebrovascular reactivity (CVR), i.e., the ability of cerebral vasculature to dilate or constrict in response to vasoactive stimuli, is a biomarker of vascular health and CVR quantification is considered an unmet clinical need. However, the value of addressing this unmet need is not clear. This thesis focuses on enhancing the clinical value proposition of CVR assessments by exploring novel experimental approaches to quantify CVR and investigating CVR assessments in a previously unexplored pediatric patient population using an emerging optical neuromonitoring technology termed Diffuse Correlation Spectroscopy (DCS). DCS is an emerging low-cost, noninvasive, and portable optical tool that utilizes near-infrared light to assess cerebral hemodynamics (i.e., cerebral blood flow, cerebrovascular reactivity) at the microvascular length scale. The overall goal of this work is to explore and enhance the clinical value proposition DCS-mediated CVR assessments in pediatric patients. This work has two primary aims. In Aim #1, I hypothesize that CVR assessed with DCS using more tolerable experimental protocols will agree well with the gold standard hypercapnia challenge. In Aim #2, I hypothesize that children with SCD experience markedly reduced CVR when compared to healthy children in response to a breath hold challenge. The ultimate outcome of this work lends support to the clinical value of DCS-measured CVR assessed in a routine outpatient clinical workflow for a pediatric population with sickle cell disease.","abstract_html":"Cerebrovascular reactivity (CVR), i.e., the ability of cerebral vasculature to dilate or constrict in response to vasoactive stimuli, is a biomarker of vascular health and CVR quantification is considered an unmet clinical need. However, the value of addressing this unmet need is not clear. This thesis focuses on enhancing the clinical value proposition of CVR assessments by exploring novel experimental approaches to quantify CVR and investigating CVR assessments in a previously unexplored pediatric patient population using an emerging optical neuromonitoring technology termed Diffuse Correlation Spectroscopy (DCS). DCS is an emerging low-cost, noninvasive, and portable optical tool that utilizes near-infrared light to assess cerebral hemodynamics (i.e., cerebral blood flow, cerebrovascular reactivity) at the microvascular length scale. The overall goal of this work is to explore and enhance the clinical value proposition DCS-mediated CVR assessments in pediatric patients. This work has two primary aims. In Aim #1, I hypothesize that CVR assessed with DCS using more tolerable experimental protocols will agree well with the gold standard hypercapnia challenge. In Aim #2, I hypothesize that children with SCD experience markedly reduced CVR when compared to healthy children in response to a breath hold challenge. The ultimate outcome of this work lends support to the clinical value of DCS-measured CVR assessed in a routine outpatient clinical workflow for a pediatric population with sickle cell disease.","abstract_has_math":false,"creators":["Cowdrick, Kyle Robert"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Biomedical Engineering (Joint GT/Emory Department)","school":null,"contributors":[],"advisors":["Buckley, Erin"],"committee_chairs":[],"committee_members":["Margulies, Susan","Keilholz, Shella","Qiu, Deqiang","Grunwell, Jocelyn"],"year":2023,"date_issued":"2023-07-24","date_published":"2023-07-24","updated_at":"2026-11-19T03:49:12Z","subjects":["Diffuse optics","optical spectroscopy","diffuse correlation spectroscopy","medical devices","patient monitoring","neuromonitoring"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/75546","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/75546","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F75546","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Buckley, Erin"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Margulies, Susan","Keilholz, Shella","Qiu, Deqiang","Grunwell, Jocelyn"]},{"key":"dc:contributor.department","label":"Department","values":["Biomedical Engineering (Joint GT/Emory Department)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","Wallace H. Coulter Department of Biomedical Engineering"]},{"key":"dc:creator","label":"Author","values":["Cowdrick, Kyle Robert"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-08-22T15:10:01Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-08-22T15:10:01Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-08"]},{"key":"dc:date.issued","label":"Date","values":["2023-07-24"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2023"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2024-08-22T15:10:02Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["eda3e638-9b26-4f1b-aff9-2ae703820239"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Biomedical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","da59be3c-3d0a-41da-91b9-ebe2ecc83b66"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["d85f9f1b-b2b5-4bca-81af-4515c5281e54"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Diffuse optics","optical spectroscopy","diffuse correlation spectroscopy","medical devices","patient monitoring","neuromonitoring"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/75546"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Cerebrovascular reactivity (CVR), i.e., the ability of cerebral vasculature to dilate or constrict in response to vasoactive stimuli, is a biomarker of vascular health and CVR quantification is considered an unmet clinical need. However, the value of addressing this unmet need is not clear. This thesis focuses on enhancing the clinical value proposition of CVR assessments by exploring novel experimental approaches to quantify CVR and investigating CVR assessments in a previously unexplored pediatric patient population using an emerging optical neuromonitoring technology termed Diffuse Correlation Spectroscopy (DCS). DCS is an emerging low-cost, noninvasive, and portable optical tool that utilizes near-infrared light to assess cerebral hemodynamics (i.e., cerebral blood flow, cerebrovascular reactivity) at the microvascular length scale. The overall goal of this work is to explore and enhance the clinical value proposition DCS-mediated CVR assessments in pediatric patients. This work has two primary aims. In Aim #1, I hypothesize that CVR assessed with DCS using more tolerable experimental protocols will agree well with the gold standard hypercapnia challenge. In Aim #2, I hypothesize that children with SCD experience markedly reduced CVR when compared to healthy children in response to a breath hold challenge. The ultimate outcome of this work lends support to the clinical value of DCS-measured CVR assessed in a routine outpatient clinical workflow for a pediatric population with sickle cell disease."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Exploring The Translational Clinical Value of Cerebrovascular Reactivity Assessments by Diffuse Correlation Spectroscopy"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Buckley, Erin"],"dc:contributor.committeemember":["Margulies, Susan","Keilholz, Shella","Qiu, Deqiang","Grunwell, Jocelyn"],"dc:contributor.department":["Biomedical Engineering (Joint GT/Emory Department)"],"dc:contributor.other":["College of Engineering","Wallace H. Coulter Department of Biomedical Engineering"],"dc:creator":["Cowdrick, Kyle Robert"],"dc:date.accessioned":["2024-08-22T15:10:01Z"],"dc:date.available":["2024-08-22T15:10:01Z"],"dc:date.created":["2023-08"],"dc:date.issued":["2023-07-24"],"dc:date.submitted":["August 2023"],"dc:date.updated":["2024-08-22T15:10:02Z"],"dc:description.abstract":["Cerebrovascular reactivity (CVR), i.e., the ability of cerebral vasculature to dilate or constrict in response to vasoactive stimuli, is a biomarker of vascular health and CVR quantification is considered an unmet clinical need. However, the value of addressing this unmet need is not clear. This thesis focuses on enhancing the clinical value proposition of CVR assessments by exploring novel experimental approaches to quantify CVR and investigating CVR assessments in a previously unexplored pediatric patient population using an emerging optical neuromonitoring technology termed Diffuse Correlation Spectroscopy (DCS). DCS is an emerging low-cost, noninvasive, and portable optical tool that utilizes near-infrared light to assess cerebral hemodynamics (i.e., cerebral blood flow, cerebrovascular reactivity) at the microvascular length scale. The overall goal of this work is to explore and enhance the clinical value proposition DCS-mediated CVR assessments in pediatric patients. This work has two primary aims. In Aim #1, I hypothesize that CVR assessed with DCS using more tolerable experimental protocols will agree well with the gold standard hypercapnia challenge. In Aim #2, I hypothesize that children with SCD experience markedly reduced CVR when compared to healthy children in response to a breath hold challenge. The ultimate outcome of this work lends support to the clinical value of DCS-measured CVR assessed in a routine outpatient clinical workflow for a pediatric population with sickle cell disease."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/75546"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["eda3e638-9b26-4f1b-aff9-2ae703820239"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Biomedical Engineering"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","da59be3c-3d0a-41da-91b9-ebe2ecc83b66"],"dc:relation.seriesentity":["d85f9f1b-b2b5-4bca-81af-4515c5281e54"],"dc:subject":["Diffuse optics","optical spectroscopy","diffuse correlation spectroscopy","medical devices","patient monitoring","neuromonitoring"],"dc:title":["Exploring The Translational Clinical Value of Cerebrovascular Reactivity Assessments by Diffuse Correlation Spectroscopy"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T03:49:12Z"}