{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/75579"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/75579","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Batteryless Membrane Sensors and Electronics for Monitoring of Cardiovascular Signals","abstract":"This thesis explores using LC resonators, composed of a thin membrane capacitive sensor and an inductor, to monitor cardiovascular signals, such as pulse, seismocardiogram (SCG), and arterial strain. LC resonators are simple and easy-to-manufacture devices that can be monitored wirelessly without batteries. This technology allows for the creation of wearable and implantable devices usually used to monitor simple bioindicators. It was demonstrated that more complex signals, such as an SCG, can be collected this way. Moreover, the optimization of the design and fabrication process of a wireless stent connected to a capacitive strain sensor to detect early signs of restenosis was also performed. The device had a 3-times increase in sensitivity compared to previous literature. The capability to detect different restenosis levels was also confirmed in in-vitro tests. The fabrication process improvements, design optimization, and sensing improvements allow more complex wireless, battery-less devices to be created.","abstract_html":"This thesis explores using LC resonators, composed of a thin membrane capacitive sensor and an inductor, to monitor cardiovascular signals, such as pulse, seismocardiogram (SCG), and arterial strain. LC resonators are simple and easy-to-manufacture devices that can be monitored wirelessly without batteries. This technology allows for the creation of wearable and implantable devices usually used to monitor simple bioindicators. It was demonstrated that more complex signals, such as an SCG, can be collected this way. Moreover, the optimization of the design and fabrication process of a wireless stent connected to a capacitive strain sensor to detect early signs of restenosis was also performed. The device had a 3-times increase in sensitivity compared to previous literature. The capability to detect different restenosis levels was also confirmed in in-vitro tests. The fabrication process improvements, design optimization, and sensing improvements allow more complex wireless, battery-less devices to be created.","abstract_has_math":false,"creators":["Rigo, Bruno V."],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Yeo, Woon-Hong","Inan, Omer T."],"committee_chairs":[],"committee_members":["Ghalichechian, Nima","Gleason, Rudolph L."],"year":2023,"date_issued":"2023-07-31","date_published":"2023-07-31","updated_at":"2026-11-19T05:17:37Z","subjects":["Bateryless","Membrane sensors","Cardiovascular"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/75579","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/75579","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F75579","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Yeo, Woon-Hong","Inan, Omer T."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Ghalichechian, Nima","Gleason, Rudolph L."]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","School of Electrical and Computer Engineering"]},{"key":"dc:creator","label":"Author","values":["Rigo, Bruno V."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-08-22T15:13:26Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-08-22T15:13:26Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-08"]},{"key":"dc:date.issued","label":"Date","values":["2023-07-31"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2023"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2024-08-22T15:13:26Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["db60c3f5-1b0a-4bd3-9184-de4173eb1685","fb82ce90-ad3a-45a6-b0e2-f1ee6fe6f744"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Electrical and Computer Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","5b7adef2-447c-4270-b9fc-846bd76f80f2"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["f8b6e739-0ecd-4831-80cd-4ef4edf0a817"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Bateryless","Membrane sensors","Cardiovascular"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/75579"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis explores using LC resonators, composed of a thin membrane capacitive sensor and an inductor, to monitor cardiovascular signals, such as pulse, seismocardiogram (SCG), and arterial strain. LC resonators are simple and easy-to-manufacture devices that can be monitored wirelessly without batteries. This technology allows for the creation of wearable and implantable devices usually used to monitor simple bioindicators. It was demonstrated that more complex signals, such as an SCG, can be collected this way. Moreover, the optimization of the design and fabrication process of a wireless stent connected to a capacitive strain sensor to detect early signs of restenosis was also performed. The device had a 3-times increase in sensitivity compared to previous literature. The capability to detect different restenosis levels was also confirmed in in-vitro tests. The fabrication process improvements, design optimization, and sensing improvements allow more complex wireless, battery-less devices to be created."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Batteryless Membrane Sensors and Electronics for Monitoring of Cardiovascular Signals"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Yeo, Woon-Hong","Inan, Omer T."],"dc:contributor.committeemember":["Ghalichechian, Nima","Gleason, Rudolph L."],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["College of Engineering","School of Electrical and Computer Engineering"],"dc:creator":["Rigo, Bruno V."],"dc:date.accessioned":["2024-08-22T15:13:26Z"],"dc:date.available":["2024-08-22T15:13:26Z"],"dc:date.created":["2023-08"],"dc:date.issued":["2023-07-31"],"dc:date.submitted":["August 2023"],"dc:date.updated":["2024-08-22T15:13:26Z"],"dc:description.abstract":["This thesis explores using LC resonators, composed of a thin membrane capacitive sensor and an inductor, to monitor cardiovascular signals, such as pulse, seismocardiogram (SCG), and arterial strain. LC resonators are simple and easy-to-manufacture devices that can be monitored wirelessly without batteries. This technology allows for the creation of wearable and implantable devices usually used to monitor simple bioindicators. It was demonstrated that more complex signals, such as an SCG, can be collected this way. Moreover, the optimization of the design and fabrication process of a wireless stent connected to a capacitive strain sensor to detect early signs of restenosis was also performed. The device had a 3-times increase in sensitivity compared to previous literature. The capability to detect different restenosis levels was also confirmed in in-vitro tests. The fabrication process improvements, design optimization, and sensing improvements allow more complex wireless, battery-less devices to be created."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/75579"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["db60c3f5-1b0a-4bd3-9184-de4173eb1685","fb82ce90-ad3a-45a6-b0e2-f1ee6fe6f744"],"dc:relation.ispartofseries":["Master of Science in Electrical and Computer Engineering"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","5b7adef2-447c-4270-b9fc-846bd76f80f2"],"dc:relation.seriesentity":["f8b6e739-0ecd-4831-80cd-4ef4edf0a817"],"dc:subject":["Bateryless","Membrane sensors","Cardiovascular"],"dc:title":["Batteryless Membrane Sensors and Electronics for Monitoring of Cardiovascular Signals"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T05:17:37Z"}