{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/7562"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/7562","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Modeling Fluid Mechanics in Individual Human Carotid Arteries","abstract":"In the interest of furthering the understanding of hemodynamics, this study has developed a method for modeling fluid mechanics behavior in individual human carotid arteries. A computational model was constructed from magnetic resonance (MR) data of a phantom carotid bifurcation model, and relevant flow conditions were simulated. Results were verified by comparison with previous in vitro experiments. The methodology was extended to create subject-specific carotid artery models from geometry data and fluid flow boundary conditions which were determined from MR and phase contrast MR (PCMR) scans of human subjects. The influence of subject-specific boundary conditions on the flow field was investigated by comparing a model based on measured velocity boundary conditions to a model based on the assumption of idealized velocity boundary conditions. It is shown that subject-specific velocity boundary conditions in combination with a subject-specific geometry and flow waveform influence fluid flow phenomena associated with plaque development. Comparing a model with idealized Womersley flow boundary conditions to a model with subject-specific velocity boundary conditions demonstrated the importance of employing inlet and flow division data obtained from individual subjects in order to predict accurate, clinically relevant, fluid flow phenomena such as low wall shear stress areas and negative axial velocity regions. This study also illustrates the influence of the bifurcation geometry, especially the flow divider position, with respect to the velocity distribution of the common carotid artery on the development of flow characteristics. Overall it is concluded that accurate geometry and velocity measurements are essential for modeling fluid mechanics in individual human carotid arteries for the purpose of understanding atherosclerosis in the carotid artery bifurcation.","abstract_html":"In the interest of furthering the understanding of hemodynamics, this study has developed a method for modeling fluid mechanics behavior in individual human carotid arteries. A computational model was constructed from magnetic resonance (MR) data of a phantom carotid bifurcation model, and relevant flow conditions were simulated. Results were verified by comparison with previous in vitro experiments. The methodology was extended to create subject-specific carotid artery models from geometry data and fluid flow boundary conditions which were determined from MR and phase contrast MR (PCMR) scans of human subjects. The influence of subject-specific boundary conditions on the flow field was investigated by comparing a model based on measured velocity boundary conditions to a model based on the assumption of idealized velocity boundary conditions. It is shown that subject-specific velocity boundary conditions in combination with a subject-specific geometry and flow waveform influence fluid flow phenomena associated with plaque development. Comparing a model with idealized Womersley flow boundary conditions to a model with subject-specific velocity boundary conditions demonstrated the importance of employing inlet and flow division data obtained from individual subjects in order to predict accurate, clinically relevant, fluid flow phenomena such as low wall shear stress areas and negative axial velocity regions. This study also illustrates the influence of the bifurcation geometry, especially the flow divider position, with respect to the velocity distribution of the common carotid artery on the development of flow characteristics. Overall it is concluded that accurate geometry and velocity measurements are essential for modeling fluid mechanics in individual human carotid arteries for the purpose of understanding atherosclerosis in the carotid artery bifurcation.","abstract_has_math":false,"creators":["Wake, Amanda Kathleen"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Biomedical Engineering","school":null,"contributors":[],"advisors":["Giddens, Don P."],"committee_chairs":[],"committee_members":["Ku, David","Oshinksi, John","Smith, Marilyn","Vito, Raymond"],"year":2005,"date_issued":"2005-11-28","date_published":"2005-11-28","updated_at":"2026-11-19T04:25:43Z","subjects":["Hemodynamics","Computational fluid dynamics","Carotid artery","Fluid mechanics","PCMR","MR","CFD","Magnetic resonance","Carotid artery Fluid dynamics Computer simulation","Body composition Models"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/7562","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/7562","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F7562","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Giddens, Don P."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Ku, David","Oshinksi, John","Smith, Marilyn","Vito, Raymond"]},{"key":"dc:contributor.department","label":"Department","values":["Biomedical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Wallace H. Coulter Department of Biomedical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Wake, Amanda Kathleen"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2006-01-18T22:23:54Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2006-01-18T22:23:54Z"]},{"key":"dc:date.issued","label":"Date","values":["2005-11-28"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Biomedical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["da59be3c-3d0a-41da-91b9-ebe2ecc83b66","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["d85f9f1b-b2b5-4bca-81af-4515c5281e54"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Hemodynamics","Computational fluid dynamics","Carotid artery","Fluid mechanics","PCMR","MR","CFD"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Magnetic resonance","Hemodynamics","Carotid artery Fluid dynamics Computer simulation","Body composition Models"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/7562"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In the interest of furthering the understanding of hemodynamics, this study has developed a method for modeling fluid mechanics behavior in individual human carotid arteries. A computational model was constructed from magnetic resonance (MR) data of a phantom carotid bifurcation model, and relevant flow conditions were simulated. Results were verified by comparison with previous in vitro experiments. The methodology was extended to create subject-specific carotid artery models from geometry data and fluid flow boundary conditions which were determined from MR and phase contrast MR (PCMR) scans of human subjects. The influence of subject-specific boundary conditions on the flow field was investigated by comparing a model based on measured velocity boundary conditions to a model based on the assumption of idealized velocity boundary conditions. It is shown that subject-specific velocity boundary conditions in combination with a subject-specific geometry and flow waveform influence fluid flow phenomena associated with plaque development. Comparing a model with idealized Womersley flow boundary conditions to a model with subject-specific velocity boundary conditions demonstrated the importance of employing inlet and flow division data obtained from individual subjects in order to predict accurate, clinically relevant, fluid flow phenomena such as low wall shear stress areas and negative axial velocity regions. This study also illustrates the influence of the bifurcation geometry, especially the flow divider position, with respect to the velocity distribution of the common carotid artery on the development of flow characteristics. Overall it is concluded that accurate geometry and velocity measurements are essential for modeling fluid mechanics in individual human carotid arteries for the purpose of understanding atherosclerosis in the carotid artery bifurcation."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["2252356 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Modeling Fluid Mechanics in Individual Human Carotid Arteries"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Giddens, Don P."],"dc:contributor.committeemember":["Ku, David","Oshinksi, John","Smith, Marilyn","Vito, Raymond"],"dc:contributor.department":["Biomedical Engineering"],"dc:contributor.other":["Wallace H. Coulter Department of Biomedical Engineering","College of Engineering"],"dc:creator":["Wake, Amanda Kathleen"],"dc:date.accessioned":["2006-01-18T22:23:54Z"],"dc:date.available":["2006-01-18T22:23:54Z"],"dc:date.issued":["2005-11-28"],"dc:description.abstract":["In the interest of furthering the understanding of hemodynamics, this study has developed a method for modeling fluid mechanics behavior in individual human carotid arteries. A computational model was constructed from magnetic resonance (MR) data of a phantom carotid bifurcation model, and relevant flow conditions were simulated. Results were verified by comparison with previous in vitro experiments. The methodology was extended to create subject-specific carotid artery models from geometry data and fluid flow boundary conditions which were determined from MR and phase contrast MR (PCMR) scans of human subjects. The influence of subject-specific boundary conditions on the flow field was investigated by comparing a model based on measured velocity boundary conditions to a model based on the assumption of idealized velocity boundary conditions. It is shown that subject-specific velocity boundary conditions in combination with a subject-specific geometry and flow waveform influence fluid flow phenomena associated with plaque development. Comparing a model with idealized Womersley flow boundary conditions to a model with subject-specific velocity boundary conditions demonstrated the importance of employing inlet and flow division data obtained from individual subjects in order to predict accurate, clinically relevant, fluid flow phenomena such as low wall shear stress areas and negative axial velocity regions. This study also illustrates the influence of the bifurcation geometry, especially the flow divider position, with respect to the velocity distribution of the common carotid artery on the development of flow characteristics. Overall it is concluded that accurate geometry and velocity measurements are essential for modeling fluid mechanics in individual human carotid arteries for the purpose of understanding atherosclerosis in the carotid artery bifurcation."],"dc:description.degree":["Ph.D."],"dc:format.extent":["2252356 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/7562"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Biomedical Engineering"],"dc:relation.orgunit":["da59be3c-3d0a-41da-91b9-ebe2ecc83b66","7c022d60-21d5-497c-b552-95e489a06569"],"dc:relation.seriesentity":["d85f9f1b-b2b5-4bca-81af-4515c5281e54"],"dc:subject":["Hemodynamics","Computational fluid dynamics","Carotid artery","Fluid mechanics","PCMR","MR","CFD"],"dc:subject.lcsh":["Magnetic resonance","Hemodynamics","Carotid artery Fluid dynamics Computer simulation","Body composition Models"],"dc:title":["Modeling Fluid Mechanics in Individual Human Carotid Arteries"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T04:25:43Z"}