{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/75630"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/75630","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"A Wireless Wearable System for Closed-Loop Stress Detection and Mitigation","abstract":"This work presents the development and optimization of a novel wearable device designed for real-time stress detection and mitigation through electrical nerve stimulation. It features wireless data monitoring and control of stimulation parameters via a cross-platform app using Bluetooth Low Energy (BLE). System enhancements focus on hardware and firmware improvements, including wireless functionality and robust real-time measurement and processing of stress-related biomarkers. The device utilizes accelerometers and optical-sensor-LED-pairs for continuous measurement of photoplethysmogram (PPG) and acceleration data, providing insights into stress levels of a user. The thesis documents the design process, decisions, and optimizations related to the device’s hardware, firmware, and supporting software, along with characterization of the completed prototype and bench-top testing data demonstrating its functionality.","abstract_html":"This work presents the development and optimization of a novel wearable device designed for real-time stress detection and mitigation through electrical nerve stimulation. It features wireless data monitoring and control of stimulation parameters via a cross-platform app using Bluetooth Low Energy (BLE). System enhancements focus on hardware and firmware improvements, including wireless functionality and robust real-time measurement and processing of stress-related biomarkers. The device utilizes accelerometers and optical-sensor-LED-pairs for continuous measurement of photoplethysmogram (PPG) and acceleration data, providing insights into stress levels of a user. The thesis documents the design process, decisions, and optimizations related to the device’s hardware, firmware, and supporting software, along with characterization of the completed prototype and bench-top testing data demonstrating its functionality.","abstract_has_math":false,"creators":["Bindra, Prabhkirat Singh"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Inan, Omer T."],"committee_chairs":[],"committee_members":["Hahn, Jin-Oh","Mahmoudi, Babak","Sangodoyin, Seun"],"year":2024,"date_issued":"2024-05-17","date_published":"2024-05-17","updated_at":"2026-11-19T05:17:50Z","subjects":["Wearable","Stress detection","Stress mitigation","Photoplethysmogram","Accelerometry","Closed-loop control","Microcontroller","Sensors","Battery","Stimulation","Data storage","Bluetooth low energy","Firmware","Software","Cross-platform app","Wireless","3D printing","Hardware","Embedded system","Vagus nerve stimulation","Peripheral nerve stimulation","Autonomic nervous system","Real-time processing","Biomarkers"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/75630","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/75630","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F75630","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Inan, Omer T."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Hahn, Jin-Oh","Mahmoudi, Babak","Sangodoyin, Seun"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","School of Electrical and Computer Engineering"]},{"key":"dc:creator","label":"Author","values":["Bindra, Prabhkirat Singh"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-08-22T15:16:23Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-08-22T15:16:23Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2024-08"]},{"key":"dc:date.issued","label":"Date","values":["2024-05-17"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2024"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2024-08-22T15:16:23Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["fb82ce90-ad3a-45a6-b0e2-f1ee6fe6f744"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Bioengineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","5b7adef2-447c-4270-b9fc-846bd76f80f2"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["a5c9fe8c-5d03-4de6-a761-459fb2af0dea"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Wearable","Stress detection","Stress mitigation","Photoplethysmogram","Accelerometry","Closed-loop control","Microcontroller","Sensors","Battery","Stimulation","Data storage","Bluetooth low energy","Firmware","Software","Cross-platform app","Wireless","3D printing","Hardware","Embedded system","Vagus nerve stimulation","Peripheral nerve stimulation","Autonomic nervous system","Real-time processing","Biomarkers"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/75630"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This work presents the development and optimization of a novel wearable device designed for real-time stress detection and mitigation through electrical nerve stimulation. It features wireless data monitoring and control of stimulation parameters via a cross-platform app using Bluetooth Low Energy (BLE). System enhancements focus on hardware and firmware improvements, including wireless functionality and robust real-time measurement and processing of stress-related biomarkers. The device utilizes accelerometers and optical-sensor-LED-pairs for continuous measurement of photoplethysmogram (PPG) and acceleration data, providing insights into stress levels of a user. The thesis documents the design process, decisions, and optimizations related to the device’s hardware, firmware, and supporting software, along with characterization of the completed prototype and bench-top testing data demonstrating its functionality."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A Wireless Wearable System for Closed-Loop Stress Detection and Mitigation"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Inan, Omer T."],"dc:contributor.committeemember":["Hahn, Jin-Oh","Mahmoudi, Babak","Sangodoyin, Seun"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["College of Engineering","School of Electrical and Computer Engineering"],"dc:creator":["Bindra, Prabhkirat Singh"],"dc:date.accessioned":["2024-08-22T15:16:23Z"],"dc:date.available":["2024-08-22T15:16:23Z"],"dc:date.created":["2024-08"],"dc:date.issued":["2024-05-17"],"dc:date.submitted":["August 2024"],"dc:date.updated":["2024-08-22T15:16:23Z"],"dc:description.abstract":["This work presents the development and optimization of a novel wearable device designed for real-time stress detection and mitigation through electrical nerve stimulation. It features wireless data monitoring and control of stimulation parameters via a cross-platform app using Bluetooth Low Energy (BLE). System enhancements focus on hardware and firmware improvements, including wireless functionality and robust real-time measurement and processing of stress-related biomarkers. The device utilizes accelerometers and optical-sensor-LED-pairs for continuous measurement of photoplethysmogram (PPG) and acceleration data, providing insights into stress levels of a user. The thesis documents the design process, decisions, and optimizations related to the device’s hardware, firmware, and supporting software, along with characterization of the completed prototype and bench-top testing data demonstrating its functionality."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/75630"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["fb82ce90-ad3a-45a6-b0e2-f1ee6fe6f744"],"dc:relation.ispartofseries":["Master of Science in Bioengineering"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","5b7adef2-447c-4270-b9fc-846bd76f80f2"],"dc:relation.seriesentity":["a5c9fe8c-5d03-4de6-a761-459fb2af0dea"],"dc:subject":["Wearable","Stress detection","Stress mitigation","Photoplethysmogram","Accelerometry","Closed-loop control","Microcontroller","Sensors","Battery","Stimulation","Data storage","Bluetooth low energy","Firmware","Software","Cross-platform app","Wireless","3D printing","Hardware","Embedded system","Vagus nerve stimulation","Peripheral nerve stimulation","Autonomic nervous system","Real-time processing","Biomarkers"],"dc:title":["A Wireless Wearable System for Closed-Loop Stress Detection and Mitigation"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T05:17:50Z"}