{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/75677"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/75677","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Design and optimization of mini-beam GRID and LATTICE therapy using linear accelerators","abstract":"Dose-Volume effects have been shown to increase the radiation dose tolerance of critical organs-at-risk (OARs) in multiple normal tissues such as the brainstem, spinal cord, parotid glands and in animal models. The irradiated volume must be kept “small” on the order of millimeters for tissues to experience additional protection from dose-volume effects. Mouse ears have demonstrated minimal toxicity from more than 60 Gy of single-fraction dose when the beam width was kept below 2 mm. Spatially Fractionated Radiation Therapy (SFRT) aims to deliver heterogeneous peak and valley dose regions to the tumor in contrast to homogeneous dose techniques such as intensity modulated radiotherapy (IMRT). A form of SFRT called minibeam radiation therapy (MBRT) typically uses beams on the order of sub-millimeter to a few millimeters which is within the size range for exploitation of dose-volume effects, but the connection between SFRT, MBRT and dose-volume effects has not been thoroughly explored. Glioma and glioblastoma are aggressive, radioresistant primary brain tumors with bleak prognosis and minimal treatment options, but LINAC-based photon MBRT in an animal study demonstrated complete tumor response for glioma when compared to stereotactic radiosurgery which only showed partial tumor remission. These results motivated this thesis work to develop novel techniques for delivering LINAC-based MBRT for overcoming radioresistance of aggressive tumors such as glioma/glioblastoma. In this thesis, the novel techniques of 2D “en face” honeycomb LINAC-MBRT, 3D “mini-LATTICE”, and “4π-MBRT” are developed and explained. This thesis will show that with modifications to existing commercially available medical linear accelerators, LINAC-MBRT can be implemented with MV-photon beams to increase the therapeutic ratio and treatment outcomes of radioresistant diseases such as glioma/glioblastoma.","abstract_html":"Dose-Volume effects have been shown to increase the radiation dose tolerance of critical organs-at-risk (OARs) in multiple normal tissues such as the brainstem, spinal cord, parotid glands and in animal models. The irradiated volume must be kept “small” on the order of millimeters for tissues to experience additional protection from dose-volume effects. Mouse ears have demonstrated minimal toxicity from more than 60 Gy of single-fraction dose when the beam width was kept below 2 mm. Spatially Fractionated Radiation Therapy (SFRT) aims to deliver heterogeneous peak and valley dose regions to the tumor in contrast to homogeneous dose techniques such as intensity modulated radiotherapy (IMRT). A form of SFRT called minibeam radiation therapy (MBRT) typically uses beams on the order of sub-millimeter to a few millimeters which is within the size range for exploitation of dose-volume effects, but the connection between SFRT, MBRT and dose-volume effects has not been thoroughly explored. Glioma and glioblastoma are aggressive, radioresistant primary brain tumors with bleak prognosis and minimal treatment options, but LINAC-based photon MBRT in an animal study demonstrated complete tumor response for glioma when compared to stereotactic radiosurgery which only showed partial tumor remission. These results motivated this thesis work to develop novel techniques for delivering LINAC-based MBRT for overcoming radioresistance of aggressive tumors such as glioma/glioblastoma. In this thesis, the novel techniques of 2D “en face” honeycomb LINAC-MBRT, 3D “mini-LATTICE”, and “4π-MBRT” are developed and explained. This thesis will show that with modifications to existing commercially available medical linear accelerators, LINAC-MBRT can be implemented with MV-photon beams to increase the therapeutic ratio and treatment outcomes of radioresistant diseases such as glioma/glioblastoma.","abstract_has_math":false,"creators":["Carter, Zachary Gray"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Wang, C.-K. Chris"],"committee_chairs":[],"committee_members":["Brooks, Kenneth","Elder, Eric","Roper, Justin","Erickson, Anna"],"year":2024,"date_issued":"2024-07-19","date_published":"2024-07-19","updated_at":"2026-11-19T05:03:59Z","subjects":["GRID","LATTICE","Radiation Therapy","Radiation Oncology","Spatially Fractionated Radiation Therapy","SFRT","cancer","cancer treatment","radiation","megavoltage photon","megavoltage","LINAC","linear accelerator","Spatially Fractionated Radiotherapy"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/75677","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/75677","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F75677","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Wang, C.-K. Chris"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Brooks, Kenneth","Elder, Eric","Roper, Justin","Erickson, Anna"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","George W. Woodruff School of Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Carter, Zachary Gray"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-08-22T15:20:04Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-08-22T15:20:04Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2024-08"]},{"key":"dc:date.issued","label":"Date","values":["2024-07-19"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2024"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2024-08-22T15:20:06Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["71d23899-d6d4-4d7f-b9bc-d30323a6f442"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Nuclear Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","c01ff908-c25f-439b-bf10-a074ed886bb7"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["b2bc2e12-2afc-4a4d-bf4c-0ce7832bcefe"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["GRID","LATTICE","Radiation Therapy","Radiation Oncology","Spatially Fractionated Radiation Therapy","SFRT","cancer","cancer treatment","radiation","megavoltage photon","megavoltage","LINAC","linear accelerator","Spatially Fractionated Radiotherapy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/75677"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Dose-Volume effects have been shown to increase the radiation dose tolerance of critical organs-at-risk (OARs) in multiple normal tissues such as the brainstem, spinal cord, parotid glands and in animal models. The irradiated volume must be kept “small” on the order of millimeters for tissues to experience additional protection from dose-volume effects. Mouse ears have demonstrated minimal toxicity from more than 60 Gy of single-fraction dose when the beam width was kept below 2 mm. Spatially Fractionated Radiation Therapy (SFRT) aims to deliver heterogeneous peak and valley dose regions to the tumor in contrast to homogeneous dose techniques such as intensity modulated radiotherapy (IMRT). A form of SFRT called minibeam radiation therapy (MBRT) typically uses beams on the order of sub-millimeter to a few millimeters which is within the size range for exploitation of dose-volume effects, but the connection between SFRT, MBRT and dose-volume effects has not been thoroughly explored. Glioma and glioblastoma are aggressive, radioresistant primary brain tumors with bleak prognosis and minimal treatment options, but LINAC-based photon MBRT in an animal study demonstrated complete tumor response for glioma when compared to stereotactic radiosurgery which only showed partial tumor remission. These results motivated this thesis work to develop novel techniques for delivering LINAC-based MBRT for overcoming radioresistance of aggressive tumors such as glioma/glioblastoma. In this thesis, the novel techniques of 2D “en face” honeycomb LINAC-MBRT, 3D “mini-LATTICE”, and “4π-MBRT” are developed and explained. This thesis will show that with modifications to existing commercially available medical linear accelerators, LINAC-MBRT can be implemented with MV-photon beams to increase the therapeutic ratio and treatment outcomes of radioresistant diseases such as glioma/glioblastoma."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Design and optimization of mini-beam GRID and LATTICE therapy using linear accelerators"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Wang, C.-K. Chris"],"dc:contributor.committeemember":["Brooks, Kenneth","Elder, Eric","Roper, Justin","Erickson, Anna"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["College of Engineering","George W. Woodruff School of Mechanical Engineering"],"dc:creator":["Carter, Zachary Gray"],"dc:date.accessioned":["2024-08-22T15:20:04Z"],"dc:date.available":["2024-08-22T15:20:04Z"],"dc:date.created":["2024-08"],"dc:date.issued":["2024-07-19"],"dc:date.submitted":["August 2024"],"dc:date.updated":["2024-08-22T15:20:06Z"],"dc:description.abstract":["Dose-Volume effects have been shown to increase the radiation dose tolerance of critical organs-at-risk (OARs) in multiple normal tissues such as the brainstem, spinal cord, parotid glands and in animal models. The irradiated volume must be kept “small” on the order of millimeters for tissues to experience additional protection from dose-volume effects. Mouse ears have demonstrated minimal toxicity from more than 60 Gy of single-fraction dose when the beam width was kept below 2 mm. Spatially Fractionated Radiation Therapy (SFRT) aims to deliver heterogeneous peak and valley dose regions to the tumor in contrast to homogeneous dose techniques such as intensity modulated radiotherapy (IMRT). A form of SFRT called minibeam radiation therapy (MBRT) typically uses beams on the order of sub-millimeter to a few millimeters which is within the size range for exploitation of dose-volume effects, but the connection between SFRT, MBRT and dose-volume effects has not been thoroughly explored. Glioma and glioblastoma are aggressive, radioresistant primary brain tumors with bleak prognosis and minimal treatment options, but LINAC-based photon MBRT in an animal study demonstrated complete tumor response for glioma when compared to stereotactic radiosurgery which only showed partial tumor remission. These results motivated this thesis work to develop novel techniques for delivering LINAC-based MBRT for overcoming radioresistance of aggressive tumors such as glioma/glioblastoma. In this thesis, the novel techniques of 2D “en face” honeycomb LINAC-MBRT, 3D “mini-LATTICE”, and “4π-MBRT” are developed and explained. This thesis will show that with modifications to existing commercially available medical linear accelerators, LINAC-MBRT can be implemented with MV-photon beams to increase the therapeutic ratio and treatment outcomes of radioresistant diseases such as glioma/glioblastoma."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/75677"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["71d23899-d6d4-4d7f-b9bc-d30323a6f442"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Nuclear Engineering"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","c01ff908-c25f-439b-bf10-a074ed886bb7"],"dc:relation.seriesentity":["b2bc2e12-2afc-4a4d-bf4c-0ce7832bcefe"],"dc:subject":["GRID","LATTICE","Radiation Therapy","Radiation Oncology","Spatially Fractionated Radiation Therapy","SFRT","cancer","cancer treatment","radiation","megavoltage photon","megavoltage","LINAC","linear accelerator","Spatially Fractionated Radiotherapy"],"dc:title":["Design and optimization of mini-beam GRID and LATTICE therapy using linear accelerators"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"]},"updated_at":"2026-11-19T05:03:59Z"}