{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/75738"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/75738","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"A New Luminescence-Based Assay for Monitoring Mutant Myocilin Cellular Localization","abstract":"Glaucoma is a heterogenous eye disease that is the leading cause of irreversible blindness worldwide, caused by a blockage in the outflow of aqueous humor from the eye, leading to an increase in intraocular pressure. The most common glaucoma subtype is primary open angle glaucoma, affecting ~60 million people worldwide. 2-4% of primary open angle glaucoma (POAG) and 10% of juvenile open angle glaucoma (JOAG) cases are attributed to mutations in the gene encoding for the protein myocilin. One of the key characteristics of a pathogenic variant is its inability to be secreted from trabecular meshwork cells. Instead of secretion, pathogenic myocilin variants accumulate in the endoplasmic reticulum and causes cell death. Mutant myocilins are studied in the lab using cellular secretion assays. In the past, different cellular fractions were detected using immunoblot, which has sensitivity limitations. In this thesis, we implement a new method that utilizes HiBiT, a luciferase-based assay, which we hypothesized would be more sensitive than immunoblot. The myocilin mutants tested using HiBiT (T377K, T377R, D384G, D395ins, C433Y, T455K, and L486F) to detect myocilin cellular localization exhibited negligible secretion when compared to WT. In addition, all the mutants except for L486F accumulated intracellularly. Unexpectedly, L486F was not detected intracellularly to the same degree as the other mutants, as evidenced by low band intensity in both the western and HiBiT blots for all three fractions. HiBiT blotting provides more sensitive detection than traditional immunoblotting, as evidenced by increased band intensity in the HiBiT blots for the same sample and lower quantities of cells needed for robust detection. Further studies on L486F will be required to determine whether it is poorly expressed or being degraded intracellularly. Overall, HiBiT detection of mutant myocilin enables new insights to be made into the mechanism of myocilin-associated POAG.","abstract_html":"Glaucoma is a heterogenous eye disease that is the leading cause of irreversible blindness worldwide, caused by a blockage in the outflow of aqueous humor from the eye, leading to an increase in intraocular pressure. The most common glaucoma subtype is primary open angle glaucoma, affecting ~60 million people worldwide. 2-4% of primary open angle glaucoma (POAG) and 10% of juvenile open angle glaucoma (JOAG) cases are attributed to mutations in the gene encoding for the protein myocilin. One of the key characteristics of a pathogenic variant is its inability to be secreted from trabecular meshwork cells. Instead of secretion, pathogenic myocilin variants accumulate in the endoplasmic reticulum and causes cell death. Mutant myocilins are studied in the lab using cellular secretion assays. In the past, different cellular fractions were detected using immunoblot, which has sensitivity limitations. In this thesis, we implement a new method that utilizes HiBiT, a luciferase-based assay, which we hypothesized would be more sensitive than immunoblot. The myocilin mutants tested using HiBiT (T377K, T377R, D384G, D395ins, C433Y, T455K, and L486F) to detect myocilin cellular localization exhibited negligible secretion when compared to WT. In addition, all the mutants except for L486F accumulated intracellularly. Unexpectedly, L486F was not detected intracellularly to the same degree as the other mutants, as evidenced by low band intensity in both the western and HiBiT blots for all three fractions. HiBiT blotting provides more sensitive detection than traditional immunoblotting, as evidenced by increased band intensity in the HiBiT blots for the same sample and lower quantities of cells needed for robust detection. Further studies on L486F will be required to determine whether it is poorly expressed or being degraded intracellularly. Overall, HiBiT detection of mutant myocilin enables new insights to be made into the mechanism of myocilin-associated POAG.","abstract_has_math":false,"creators":["Harris, Ethan Foley"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Chemistry and Biochemistry","school":null,"contributors":[],"advisors":["Lieberman, Raquel L."],"committee_chairs":[],"committee_members":["Das, Aditi","Oyelere, Adegboyega \"Yomi\""],"year":2024,"date_issued":"2024-07-30","date_published":"2024-07-30","updated_at":"2026-11-19T06:13:37Z","subjects":["Glaucoma","myocilin","luminescence","mutant"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/75738","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/75738","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F75738","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Lieberman, Raquel L."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Das, Aditi","Oyelere, Adegboyega \"Yomi\""]},{"key":"dc:contributor.department","label":"Department","values":["Chemistry and Biochemistry"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Sciences","School of Chemistry and Biochemistry"]},{"key":"dc:creator","label":"Author","values":["Harris, Ethan Foley"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-08-22T15:26:15Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-08-22T15:26:15Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2024-08"]},{"key":"dc:date.issued","label":"Date","values":["2024-07-30"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2024"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2024-08-22T15:26:16Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["03c80fe5-3e56-4361-971a-cc73d26ee837"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Chemistry"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["85042be6-2d68-4e07-b384-e1f908fae48a","f1725b93-3ab8-4c47-a4c3-3596c03d6f1e"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["8954817e-f914-4a18-bccd-8e0ecaf17c10"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Glaucoma","myocilin","luminescence","mutant"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/75738"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Glaucoma is a heterogenous eye disease that is the leading cause of irreversible blindness worldwide, caused by a blockage in the outflow of aqueous humor from the eye, leading to an increase in intraocular pressure. The most common glaucoma subtype is primary open angle glaucoma, affecting ~60 million people worldwide. 2-4% of primary open angle glaucoma (POAG) and 10% of juvenile open angle glaucoma (JOAG) cases are attributed to mutations in the gene encoding for the protein myocilin. One of the key characteristics of a pathogenic variant is its inability to be secreted from trabecular meshwork cells. Instead of secretion, pathogenic myocilin variants accumulate in the endoplasmic reticulum and causes cell death. Mutant myocilins are studied in the lab using cellular secretion assays. In the past, different cellular fractions were detected using immunoblot, which has sensitivity limitations. In this thesis, we implement a new method that utilizes HiBiT, a luciferase-based assay, which we hypothesized would be more sensitive than immunoblot. The myocilin mutants tested using HiBiT (T377K, T377R, D384G, D395ins, C433Y, T455K, and L486F) to detect myocilin cellular localization exhibited negligible secretion when compared to WT. In addition, all the mutants except for L486F accumulated intracellularly. Unexpectedly, L486F was not detected intracellularly to the same degree as the other mutants, as evidenced by low band intensity in both the western and HiBiT blots for all three fractions. HiBiT blotting provides more sensitive detection than traditional immunoblotting, as evidenced by increased band intensity in the HiBiT blots for the same sample and lower quantities of cells needed for robust detection. Further studies on L486F will be required to determine whether it is poorly expressed or being degraded intracellularly. Overall, HiBiT detection of mutant myocilin enables new insights to be made into the mechanism of myocilin-associated POAG."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A New Luminescence-Based Assay for Monitoring Mutant Myocilin Cellular Localization"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Lieberman, Raquel L."],"dc:contributor.committeemember":["Das, Aditi","Oyelere, Adegboyega \"Yomi\""],"dc:contributor.department":["Chemistry and Biochemistry"],"dc:contributor.other":["College of Sciences","School of Chemistry and Biochemistry"],"dc:creator":["Harris, Ethan Foley"],"dc:date.accessioned":["2024-08-22T15:26:15Z"],"dc:date.available":["2024-08-22T15:26:15Z"],"dc:date.created":["2024-08"],"dc:date.issued":["2024-07-30"],"dc:date.submitted":["August 2024"],"dc:date.updated":["2024-08-22T15:26:16Z"],"dc:description.abstract":["Glaucoma is a heterogenous eye disease that is the leading cause of irreversible blindness worldwide, caused by a blockage in the outflow of aqueous humor from the eye, leading to an increase in intraocular pressure. The most common glaucoma subtype is primary open angle glaucoma, affecting ~60 million people worldwide. 2-4% of primary open angle glaucoma (POAG) and 10% of juvenile open angle glaucoma (JOAG) cases are attributed to mutations in the gene encoding for the protein myocilin. One of the key characteristics of a pathogenic variant is its inability to be secreted from trabecular meshwork cells. Instead of secretion, pathogenic myocilin variants accumulate in the endoplasmic reticulum and causes cell death. Mutant myocilins are studied in the lab using cellular secretion assays. In the past, different cellular fractions were detected using immunoblot, which has sensitivity limitations. In this thesis, we implement a new method that utilizes HiBiT, a luciferase-based assay, which we hypothesized would be more sensitive than immunoblot. The myocilin mutants tested using HiBiT (T377K, T377R, D384G, D395ins, C433Y, T455K, and L486F) to detect myocilin cellular localization exhibited negligible secretion when compared to WT. In addition, all the mutants except for L486F accumulated intracellularly. Unexpectedly, L486F was not detected intracellularly to the same degree as the other mutants, as evidenced by low band intensity in both the western and HiBiT blots for all three fractions. HiBiT blotting provides more sensitive detection than traditional immunoblotting, as evidenced by increased band intensity in the HiBiT blots for the same sample and lower quantities of cells needed for robust detection. Further studies on L486F will be required to determine whether it is poorly expressed or being degraded intracellularly. Overall, HiBiT detection of mutant myocilin enables new insights to be made into the mechanism of myocilin-associated POAG."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/75738"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["03c80fe5-3e56-4361-971a-cc73d26ee837"],"dc:relation.ispartofseries":["Master of Science in Chemistry"],"dc:relation.orgunit":["85042be6-2d68-4e07-b384-e1f908fae48a","f1725b93-3ab8-4c47-a4c3-3596c03d6f1e"],"dc:relation.seriesentity":["8954817e-f914-4a18-bccd-8e0ecaf17c10"],"dc:subject":["Glaucoma","myocilin","luminescence","mutant"],"dc:title":["A New Luminescence-Based Assay for Monitoring Mutant Myocilin Cellular Localization"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T06:13:37Z"}