{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/7587"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/7587","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Handheld gamma-ray spectrometry for assaying radioactive materials in lungs","abstract":"After a Radiological Dispersal Device (RDD) event, there will not be time to transport people to a whole-body-counter (WBC), since it is a specialized instrument. This work will assess the feasibility of using handheld spectrometers for measuring the radioactivity that may have been inhaled by a victim as a consequence of an RDD event. Measurements were made with a handheld isotope identifier using a slab phantom and several radioactive point sources. A Lawrence Livermore National Laboratory (LLNL) Realistic Torso Phantom and a set of phantoms based on Medical Internal Radiation Dose (MIRD) reports were also used in this work. These phantoms include the human skeleton and have tissue-equivalent organs. Computational models were developed of all of the phantoms using the Monte Carlo Transport code MCNP. After validation of the computer model, MCNP runs were conducted using other sources that are likely to be used in a RDD. Calculations were then done to find the Minimum Detectable Activity (MDA) of all sources used. The Minimum Detectable Dose (MDD) was then calculated for the MIRD phantoms at various times after inhalation.","abstract_html":"After a Radiological Dispersal Device (RDD) event, there will not be time to transport people to a whole-body-counter (WBC), since it is a specialized instrument. This work will assess the feasibility of using handheld spectrometers for measuring the radioactivity that may have been inhaled by a victim as a consequence of an RDD event. Measurements were made with a handheld isotope identifier using a slab phantom and several radioactive point sources. A Lawrence Livermore National Laboratory (LLNL) Realistic Torso Phantom and a set of phantoms based on Medical Internal Radiation Dose (MIRD) reports were also used in this work. These phantoms include the human skeleton and have tissue-equivalent organs. Computational models were developed of all of the phantoms using the Monte Carlo Transport code MCNP. After validation of the computer model, MCNP runs were conducted using other sources that are likely to be used in a RDD. Calculations were then done to find the Minimum Detectable Activity (MDA) of all sources used. The Minimum Detectable Dose (MDD) was then calculated for the MIRD phantoms at various times after inhalation.","abstract_has_math":false,"creators":["Hutchinson, Jesson"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Hertel, Nolan E."],"committee_chairs":[],"committee_members":["Ansari, Armin","Wang, C-K Chris"],"year":2005,"date_issued":"2005-11-29","date_published":"2005-11-29","updated_at":"2026-11-19T05:50:17Z","subjects":["Gamma ray spectrometry","Handheld spectrometry","Phantoms (Radiology)","Radiological dispersal device"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1853/7587","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1853/7587","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F7587","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Hertel, Nolan E."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Ansari, Armin","Wang, C-K Chris"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["George W. Woodruff School of Mechanical Engineering","College of Engineering"]},{"key":"dc:creator","label":"Author","values":["Hutchinson, Jesson"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2006-01-18T22:26:37Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2006-01-18T22:26:37Z"]},{"key":"dc:date.issued","label":"Date","values":["2005-11-29"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["26003284-0ae0-4887-a127-917eb8923925"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Gamma ray spectrometry","Handheld spectrometry","Phantoms (Radiology)","Radiological dispersal device"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1853/7587"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["After a Radiological Dispersal Device (RDD) event, there will not be time to transport people to a whole-body-counter (WBC), since it is a specialized instrument. This work will assess the feasibility of using handheld spectrometers for measuring the radioactivity that may have been inhaled by a victim as a consequence of an RDD event. Measurements were made with a handheld isotope identifier using a slab phantom and several radioactive point sources. A Lawrence Livermore National Laboratory (LLNL) Realistic Torso Phantom and a set of phantoms based on Medical Internal Radiation Dose (MIRD) reports were also used in this work. These phantoms include the human skeleton and have tissue-equivalent organs. Computational models were developed of all of the phantoms using the Monte Carlo Transport code MCNP. After validation of the computer model, MCNP runs were conducted using other sources that are likely to be used in a RDD. Calculations were then done to find the Minimum Detectable Activity (MDA) of all sources used. The Minimum Detectable Dose (MDD) was then calculated for the MIRD phantoms at various times after inhalation."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["745255 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Handheld gamma-ray spectrometry for assaying radioactive materials in lungs"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Hertel, Nolan E."],"dc:contributor.committeemember":["Ansari, Armin","Wang, C-K Chris"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["George W. Woodruff School of Mechanical Engineering","College of Engineering"],"dc:creator":["Hutchinson, Jesson"],"dc:date.accessioned":["2006-01-18T22:26:37Z"],"dc:date.available":["2006-01-18T22:26:37Z"],"dc:date.issued":["2005-11-29"],"dc:description.abstract":["After a Radiological Dispersal Device (RDD) event, there will not be time to transport people to a whole-body-counter (WBC), since it is a specialized instrument. This work will assess the feasibility of using handheld spectrometers for measuring the radioactivity that may have been inhaled by a victim as a consequence of an RDD event. Measurements were made with a handheld isotope identifier using a slab phantom and several radioactive point sources. A Lawrence Livermore National Laboratory (LLNL) Realistic Torso Phantom and a set of phantoms based on Medical Internal Radiation Dose (MIRD) reports were also used in this work. These phantoms include the human skeleton and have tissue-equivalent organs. Computational models were developed of all of the phantoms using the Monte Carlo Transport code MCNP. After validation of the computer model, MCNP runs were conducted using other sources that are likely to be used in a RDD. Calculations were then done to find the Minimum Detectable Activity (MDA) of all sources used. The Minimum Detectable Dose (MDD) was then calculated for the MIRD phantoms at various times after inhalation."],"dc:description.degree":["M.S."],"dc:format.extent":["745255 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1853/7587"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["26003284-0ae0-4887-a127-917eb8923925"],"dc:relation.orgunit":["c01ff908-c25f-439b-bf10-a074ed886bb7","7c022d60-21d5-497c-b552-95e489a06569"],"dc:subject":["Gamma ray spectrometry","Handheld spectrometry","Phantoms (Radiology)","Radiological dispersal device"],"dc:title":["Handheld gamma-ray spectrometry for assaying radioactive materials in lungs"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"]},"updated_at":"2026-11-19T05:50:17Z"}