{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/76754"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/76754","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Enhanced Extraction of Dermal Interstitial Fluid Using Microneedles by Increasing Skin Water Content","abstract":"Interstitial fluid (ISF) in the skin contains biomarkers with potential use in medical diagnostics, and microneedles (MNs) provide promising low-cost and simple strategies to extract ISF. However, current MN-based systems usually extract <10 µl of ISF, which is insufficient for many applications. Here, we show that increasing pressure and water content, and degrading dermal fibers, increased ISF collected from porcine skin ex vivo. Experimental findings, supported by a fiber-matrix model of skin, demonstrated that increasing dermal water content increased pore size >5-fold, and mobile water ~2-fold. We leveraged these findings to develop an ISF collection method involving laser pre-treatment of skin to increase skin water content, MN puncture of skin to provide pathways for ISF flow, and suction used to convectively drive ISF flow. Using this method, we extracted tens of microliters of ISF from the skin of human subjects, which represents an order-of-magnitude increase compared to previous results. Overall, the laser-MN-suction system provides a simple method to sample tens of microliters of ISF from skin, which could enable study of ISF biomarkers to advance knowledge of physiology and develop ISF-based diagnostics for clinical medicine.","abstract_html":"Interstitial fluid (ISF) in the skin contains biomarkers with potential use in medical diagnostics, and microneedles (MNs) provide promising low-cost and simple strategies to extract ISF. However, current MN-based systems usually extract &lt;10 µl of ISF, which is insufficient for many applications. Here, we show that increasing pressure and water content, and degrading dermal fibers, increased ISF collected from porcine skin ex vivo. Experimental findings, supported by a fiber-matrix model of skin, demonstrated that increasing dermal water content increased pore size &gt;5-fold, and mobile water ~2-fold. We leveraged these findings to develop an ISF collection method involving laser pre-treatment of skin to increase skin water content, MN puncture of skin to provide pathways for ISF flow, and suction used to convectively drive ISF flow. Using this method, we extracted tens of microliters of ISF from the skin of human subjects, which represents an order-of-magnitude increase compared to previous results. Overall, the laser-MN-suction system provides a simple method to sample tens of microliters of ISF from skin, which could enable study of ISF biomarkers to advance knowledge of physiology and develop ISF-based diagnostics for clinical medicine.","abstract_has_math":false,"creators":["Mena Lapaix, Juan Luis Luis"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Chemical and Biomolecular Engineering","school":null,"contributors":[],"advisors":["Prausnitz, Mark R."],"committee_chairs":[],"committee_members":["Dixon, Brandon","Wilson, Corey J.","Bhamla, Saad","Koch, David"],"year":2023,"date_issued":"2023-09-05","date_published":"2023-09-05","updated_at":"2026-11-19T06:01:54Z","subjects":["dermal interstitial fluid sampling","dermal fiber matrix","porous medium","hydraulic conductivity","microneedles","skin","biomarker","medical diagnostics"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/76754","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/76754","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F76754","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Prausnitz, Mark R."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Dixon, Brandon","Wilson, Corey J.","Bhamla, Saad","Koch, David"]},{"key":"dc:contributor.department","label":"Department","values":["Chemical and Biomolecular Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","School of Chemical and Biomolecular Engineering"]},{"key":"dc:creator","label":"Author","values":["Mena Lapaix, Juan Luis Luis"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-01-15T13:31:45Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-01-15T13:31:45Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-12"]},{"key":"dc:date.issued","label":"Date","values":["2023-09-05"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2023"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2025-01-15T13:31:46Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["4bd611de-763a-4e92-abdc-0558443485cc"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Chemical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","6cfa2dc6-c5bf-4f6b-99a2-57105d8f7a6f"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["ea697a63-dfa6-4bfb-b0eb-38b9587437ee"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Chemical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["dermal interstitial fluid sampling","dermal fiber matrix","porous medium","hydraulic conductivity","microneedles","skin","biomarker","medical diagnostics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/76754"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Interstitial fluid (ISF) in the skin contains biomarkers with potential use in medical diagnostics, and microneedles (MNs) provide promising low-cost and simple strategies to extract ISF. However, current MN-based systems usually extract <10 µl of ISF, which is insufficient for many applications. Here, we show that increasing pressure and water content, and degrading dermal fibers, increased ISF collected from porcine skin ex vivo. Experimental findings, supported by a fiber-matrix model of skin, demonstrated that increasing dermal water content increased pore size >5-fold, and mobile water ~2-fold. We leveraged these findings to develop an ISF collection method involving laser pre-treatment of skin to increase skin water content, MN puncture of skin to provide pathways for ISF flow, and suction used to convectively drive ISF flow. Using this method, we extracted tens of microliters of ISF from the skin of human subjects, which represents an order-of-magnitude increase compared to previous results. Overall, the laser-MN-suction system provides a simple method to sample tens of microliters of ISF from skin, which could enable study of ISF biomarkers to advance knowledge of physiology and develop ISF-based diagnostics for clinical medicine."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Enhanced Extraction of Dermal Interstitial Fluid Using Microneedles by Increasing Skin Water Content"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Prausnitz, Mark R."],"dc:contributor.committeemember":["Dixon, Brandon","Wilson, Corey J.","Bhamla, Saad","Koch, David"],"dc:contributor.department":["Chemical and Biomolecular Engineering"],"dc:contributor.other":["College of Engineering","School of Chemical and Biomolecular Engineering"],"dc:creator":["Mena Lapaix, Juan Luis Luis"],"dc:date.accessioned":["2025-01-15T13:31:45Z"],"dc:date.available":["2025-01-15T13:31:45Z"],"dc:date.created":["2023-12"],"dc:date.issued":["2023-09-05"],"dc:date.submitted":["December 2023"],"dc:date.updated":["2025-01-15T13:31:46Z"],"dc:description.abstract":["Interstitial fluid (ISF) in the skin contains biomarkers with potential use in medical diagnostics, and microneedles (MNs) provide promising low-cost and simple strategies to extract ISF. However, current MN-based systems usually extract <10 µl of ISF, which is insufficient for many applications. Here, we show that increasing pressure and water content, and degrading dermal fibers, increased ISF collected from porcine skin ex vivo. Experimental findings, supported by a fiber-matrix model of skin, demonstrated that increasing dermal water content increased pore size >5-fold, and mobile water ~2-fold. We leveraged these findings to develop an ISF collection method involving laser pre-treatment of skin to increase skin water content, MN puncture of skin to provide pathways for ISF flow, and suction used to convectively drive ISF flow. Using this method, we extracted tens of microliters of ISF from the skin of human subjects, which represents an order-of-magnitude increase compared to previous results. Overall, the laser-MN-suction system provides a simple method to sample tens of microliters of ISF from skin, which could enable study of ISF biomarkers to advance knowledge of physiology and develop ISF-based diagnostics for clinical medicine."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/76754"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["4bd611de-763a-4e92-abdc-0558443485cc"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Chemical Engineering"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","6cfa2dc6-c5bf-4f6b-99a2-57105d8f7a6f"],"dc:relation.seriesentity":["ea697a63-dfa6-4bfb-b0eb-38b9587437ee"],"dc:subject":["dermal interstitial fluid sampling","dermal fiber matrix","porous medium","hydraulic conductivity","microneedles","skin","biomarker","medical diagnostics"],"dc:title":["Enhanced Extraction of Dermal Interstitial Fluid Using Microneedles by Increasing Skin Water Content"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"],"thesis:degree_program":["Chemical Engineering"]},"updated_at":"2026-11-19T06:01:54Z"}