{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/76834"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/76834","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Multimodal Electronic Cell Phenotyping via Multiplexed Impedance Sensors","abstract":"Cell phenotyping, vital for understanding cellular behavior, employs mechanotyping, immunophenotyping, and apoptosis assays. In this thesis, we introduce three microfluidic platforms for advanced cell phenotyping. These platforms, tailored for clinical settings, cell manufacturing, and resource-limited environments, offer novel solutions. The first platform, an electronic cytometer microchip, facilitates high-throughput cell mechanotyping through Coulter-based snapshot sensors and polymer-based fluidic channels. It measures biomechanics, deriving quantitative viscoelastic properties. The second platform performs immunoanalysis on a portable, low-cost microchip, coupled with supporting hardware and software to operate autonomously. It adeptly processes unlabeled immune cells, streamlining the immunophenotyping process and positioning itself as an advanced tool for efficient, field-deployed analysis. The third platform, an Annexin V-based apoptosis assay, integrates an electrical sensor network with a multi-stage microfluidic biochip. It captures cells based on phosphatidylserine (PS) externalization, eliminating the need for pre-labeled samples. These microfluidic platforms revolutionize on-demand cell phenotyping, delivering real-time measurements and unlocking new capabilities in cellular research and diagnostics.","abstract_html":"Cell phenotyping, vital for understanding cellular behavior, employs mechanotyping, immunophenotyping, and apoptosis assays. In this thesis, we introduce three microfluidic platforms for advanced cell phenotyping. These platforms, tailored for clinical settings, cell manufacturing, and resource-limited environments, offer novel solutions. The first platform, an electronic cytometer microchip, facilitates high-throughput cell mechanotyping through Coulter-based snapshot sensors and polymer-based fluidic channels. It measures biomechanics, deriving quantitative viscoelastic properties. The second platform performs immunoanalysis on a portable, low-cost microchip, coupled with supporting hardware and software to operate autonomously. It adeptly processes unlabeled immune cells, streamlining the immunophenotyping process and positioning itself as an advanced tool for efficient, field-deployed analysis. The third platform, an Annexin V-based apoptosis assay, integrates an electrical sensor network with a multi-stage microfluidic biochip. It captures cells based on phosphatidylserine (PS) externalization, eliminating the need for pre-labeled samples. These microfluidic platforms revolutionize on-demand cell phenotyping, delivering real-time measurements and unlocking new capabilities in cellular research and diagnostics.","abstract_has_math":false,"creators":["Arifuzzman, A. K. M."],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Sarioglu, A. Fatih"],"committee_chairs":[],"committee_members":["Degertekin , F. Levent","Frazier, Albert B.","Lam, Wilbur","Williams, Kirsten M."],"year":2023,"date_issued":"2023-12-12","date_published":"2023-12-12","updated_at":"2026-11-19T04:51:53Z","subjects":["Electrical sensor network","Cell phenotyping","Mechanotyping","Immunophenotyping","Apotosis assay","Microfluidics."],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/76834","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/76834","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F76834","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Sarioglu, A. Fatih"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Degertekin , F. Levent","Frazier, Albert B.","Lam, Wilbur","Williams, Kirsten M."]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","School of Electrical and Computer Engineering"]},{"key":"dc:creator","label":"Author","values":["Arifuzzman, A. K. M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-01-15T13:43:31Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-01-15T13:43:31Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-12"]},{"key":"dc:date.issued","label":"Date","values":["2023-12-12"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2023"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2025-01-15T13:43:36Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["a663fb68-17d4-4b9e-9342-a9fde343991e"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","5b7adef2-447c-4270-b9fc-846bd76f80f2"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Electrical and Computer Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical sensor network","Cell phenotyping","Mechanotyping","Immunophenotyping","Apotosis assay","Microfluidics."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/76834"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Cell phenotyping, vital for understanding cellular behavior, employs mechanotyping, immunophenotyping, and apoptosis assays. In this thesis, we introduce three microfluidic platforms for advanced cell phenotyping. These platforms, tailored for clinical settings, cell manufacturing, and resource-limited environments, offer novel solutions. The first platform, an electronic cytometer microchip, facilitates high-throughput cell mechanotyping through Coulter-based snapshot sensors and polymer-based fluidic channels. It measures biomechanics, deriving quantitative viscoelastic properties. The second platform performs immunoanalysis on a portable, low-cost microchip, coupled with supporting hardware and software to operate autonomously. It adeptly processes unlabeled immune cells, streamlining the immunophenotyping process and positioning itself as an advanced tool for efficient, field-deployed analysis. The third platform, an Annexin V-based apoptosis assay, integrates an electrical sensor network with a multi-stage microfluidic biochip. It captures cells based on phosphatidylserine (PS) externalization, eliminating the need for pre-labeled samples. These microfluidic platforms revolutionize on-demand cell phenotyping, delivering real-time measurements and unlocking new capabilities in cellular research and diagnostics."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Multimodal Electronic Cell Phenotyping via Multiplexed Impedance Sensors"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Sarioglu, A. Fatih"],"dc:contributor.committeemember":["Degertekin , F. Levent","Frazier, Albert B.","Lam, Wilbur","Williams, Kirsten M."],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["College of Engineering","School of Electrical and Computer Engineering"],"dc:creator":["Arifuzzman, A. K. M."],"dc:date.accessioned":["2025-01-15T13:43:31Z"],"dc:date.available":["2025-01-15T13:43:31Z"],"dc:date.created":["2023-12"],"dc:date.issued":["2023-12-12"],"dc:date.submitted":["December 2023"],"dc:date.updated":["2025-01-15T13:43:36Z"],"dc:description.abstract":["Cell phenotyping, vital for understanding cellular behavior, employs mechanotyping, immunophenotyping, and apoptosis assays. In this thesis, we introduce three microfluidic platforms for advanced cell phenotyping. These platforms, tailored for clinical settings, cell manufacturing, and resource-limited environments, offer novel solutions. The first platform, an electronic cytometer microchip, facilitates high-throughput cell mechanotyping through Coulter-based snapshot sensors and polymer-based fluidic channels. It measures biomechanics, deriving quantitative viscoelastic properties. The second platform performs immunoanalysis on a portable, low-cost microchip, coupled with supporting hardware and software to operate autonomously. It adeptly processes unlabeled immune cells, streamlining the immunophenotyping process and positioning itself as an advanced tool for efficient, field-deployed analysis. The third platform, an Annexin V-based apoptosis assay, integrates an electrical sensor network with a multi-stage microfluidic biochip. It captures cells based on phosphatidylserine (PS) externalization, eliminating the need for pre-labeled samples. These microfluidic platforms revolutionize on-demand cell phenotyping, delivering real-time measurements and unlocking new capabilities in cellular research and diagnostics."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/76834"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["a663fb68-17d4-4b9e-9342-a9fde343991e"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","5b7adef2-447c-4270-b9fc-846bd76f80f2"],"dc:relation.seriesentity":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"],"dc:subject":["Electrical sensor network","Cell phenotyping","Mechanotyping","Immunophenotyping","Apotosis assay","Microfluidics."],"dc:title":["Multimodal Electronic Cell Phenotyping via Multiplexed Impedance Sensors"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"],"thesis:degree_program":["Electrical and Computer Engineering"]},"updated_at":"2026-11-19T04:51:53Z"}