{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/76916"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/76916","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Validation of Transmission Densitometry for Holdup Characterization in Salt-Wetted MSR Components","abstract":"In-situ measurements of Molten Salt Reactor (MSR) salt deposits, known as holdup, may be performed using various non-destructive assay (NDA) techniques during operation, reprocessing, or after draining. In this project, we evaluate the efficacy of using transmission densitometry for characterization of non-radioactive holdup in salt-wetted reactor components at a laboratory scale. Specifically, the sensitivity of a 2x2 NaI(Tl) scintillation detector is evaluated through the measurement of gamma-ray transmission through variable deposition thicknesses in salt-wetted components. Measurements are performed with Ba-133, Co-57, Co-60, and Cs-137 gamma-ray sources, with pipe segments and a heat exchanger composed of stainless-steel alloy 316 (SS316). This technique is shown to be sensitive to detecting density changes in a pipe segment and heat exchanger due to FLiNaK(+EuF3) holdup inside of each component using the relationship between the transmission source energies, the attenuation properties of the metals and salt, and the detection efficiency. Experimental results are used to inform a Monte-Carlo transport model in the radiation transport code, MCNP, capable of simulating the detector response with parameterization of geometry, salt composition, and deposition profile.","abstract_html":"In-situ measurements of Molten Salt Reactor (MSR) salt deposits, known as holdup, may be performed using various non-destructive assay (NDA) techniques during operation, reprocessing, or after draining. In this project, we evaluate the efficacy of using transmission densitometry for characterization of non-radioactive holdup in salt-wetted reactor components at a laboratory scale. Specifically, the sensitivity of a 2x2 NaI(Tl) scintillation detector is evaluated through the measurement of gamma-ray transmission through variable deposition thicknesses in salt-wetted components. Measurements are performed with Ba-133, Co-57, Co-60, and Cs-137 gamma-ray sources, with pipe segments and a heat exchanger composed of stainless-steel alloy 316 (SS316). This technique is shown to be sensitive to detecting density changes in a pipe segment and heat exchanger due to FLiNaK(+EuF3) holdup inside of each component using the relationship between the transmission source energies, the attenuation properties of the metals and salt, and the detection efficiency. Experimental results are used to inform a Monte-Carlo transport model in the radiation transport code, MCNP, capable of simulating the detector response with parameterization of geometry, salt composition, and deposition profile.","abstract_has_math":false,"creators":["Bruner, Jesse"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Dewji, Shaheen"],"committee_chairs":[],"committee_members":["Biegalski, Steven","Raiman, Stephen"],"year":2024,"date_issued":"2024-11-20","date_published":"2024-11-20","updated_at":"2026-11-19T04:59:49Z","subjects":["Molten salt reactors","Nondestructive assay","Radiation detection","Spectroscopy","Holdup","Monte-carlo transport","MCNP","MC&A"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/76916","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/76916","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F76916","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Dewji, Shaheen"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Biegalski, Steven","Raiman, Stephen"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","George W. Woodruff School of Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Bruner, Jesse"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-01-15T13:53:21Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-01-15T13:53:21Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2024-12"]},{"key":"dc:date.issued","label":"Date","values":["2024-11-20"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2024"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2025-01-15T13:53:22Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["7ca9adcf-7022-42c5-9abf-160292a407ae"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Medical Physics"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","c01ff908-c25f-439b-bf10-a074ed886bb7"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["3173665c-cfb8-400b-bcf7-8fbfc614e0fb"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Medical Physics"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Molten salt reactors","Nondestructive assay","Radiation detection","Spectroscopy","Holdup","Monte-carlo transport","MCNP","MC&A"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/76916"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In-situ measurements of Molten Salt Reactor (MSR) salt deposits, known as holdup, may be performed using various non-destructive assay (NDA) techniques during operation, reprocessing, or after draining. In this project, we evaluate the efficacy of using transmission densitometry for characterization of non-radioactive holdup in salt-wetted reactor components at a laboratory scale. Specifically, the sensitivity of a 2x2 NaI(Tl) scintillation detector is evaluated through the measurement of gamma-ray transmission through variable deposition thicknesses in salt-wetted components. Measurements are performed with Ba-133, Co-57, Co-60, and Cs-137 gamma-ray sources, with pipe segments and a heat exchanger composed of stainless-steel alloy 316 (SS316). This technique is shown to be sensitive to detecting density changes in a pipe segment and heat exchanger due to FLiNaK(+EuF3) holdup inside of each component using the relationship between the transmission source energies, the attenuation properties of the metals and salt, and the detection efficiency. Experimental results are used to inform a Monte-Carlo transport model in the radiation transport code, MCNP, capable of simulating the detector response with parameterization of geometry, salt composition, and deposition profile."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Validation of Transmission Densitometry for Holdup Characterization in Salt-Wetted MSR Components"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Dewji, Shaheen"],"dc:contributor.committeemember":["Biegalski, Steven","Raiman, Stephen"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["College of Engineering","George W. Woodruff School of Mechanical Engineering"],"dc:creator":["Bruner, Jesse"],"dc:date.accessioned":["2025-01-15T13:53:21Z"],"dc:date.available":["2025-01-15T13:53:21Z"],"dc:date.created":["2024-12"],"dc:date.issued":["2024-11-20"],"dc:date.submitted":["December 2024"],"dc:date.updated":["2025-01-15T13:53:22Z"],"dc:description.abstract":["In-situ measurements of Molten Salt Reactor (MSR) salt deposits, known as holdup, may be performed using various non-destructive assay (NDA) techniques during operation, reprocessing, or after draining. In this project, we evaluate the efficacy of using transmission densitometry for characterization of non-radioactive holdup in salt-wetted reactor components at a laboratory scale. Specifically, the sensitivity of a 2x2 NaI(Tl) scintillation detector is evaluated through the measurement of gamma-ray transmission through variable deposition thicknesses in salt-wetted components. Measurements are performed with Ba-133, Co-57, Co-60, and Cs-137 gamma-ray sources, with pipe segments and a heat exchanger composed of stainless-steel alloy 316 (SS316). This technique is shown to be sensitive to detecting density changes in a pipe segment and heat exchanger due to FLiNaK(+EuF3) holdup inside of each component using the relationship between the transmission source energies, the attenuation properties of the metals and salt, and the detection efficiency. Experimental results are used to inform a Monte-Carlo transport model in the radiation transport code, MCNP, capable of simulating the detector response with parameterization of geometry, salt composition, and deposition profile."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/76916"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["7ca9adcf-7022-42c5-9abf-160292a407ae"],"dc:relation.ispartofseries":["Master of Science in Medical Physics"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","c01ff908-c25f-439b-bf10-a074ed886bb7"],"dc:relation.seriesentity":["3173665c-cfb8-400b-bcf7-8fbfc614e0fb"],"dc:subject":["Molten salt reactors","Nondestructive assay","Radiation detection","Spectroscopy","Holdup","Monte-carlo transport","MCNP","MC&A"],"dc:title":["Validation of Transmission Densitometry for Holdup Characterization in Salt-Wetted MSR Components"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"],"thesis:degree_program":["Medical Physics"]},"updated_at":"2026-11-19T04:59:49Z"}