{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/76943"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/76943","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Development of a Minibeam Delivery System for Use with a Radiation Therapy Research Platform","abstract":"Spatially fractionated radiation therapy (SFRT) utilizes multiple radiation beams to combine areas of low and high dose within the treatment volume. Organ at risk (OAR) tolerance with SFRT is greater than traditional techniques, with increasing benefits as the beam size decreases. Minibeam radiation therapy (MBRT) is a form of SFRT with beam sizes on the order of 1 mm, which is achievable utilizing conventional treatment techniques, but MBRT has only recently been used in the treatment of humans. The primary objectives of this work are to develop a system to deliver minibeam radiation therapy (MBRT) using a commercially available small animal research radiation therapy platform, perform cell survival studies comparing the survival of cells irradiated with both MBRT and broad beam (BB) dose delivery, and complete an in vivo treatment planning study to determine the dosimetric differences of different MBRT treatment delivery techniques. Most work in SFRT has focused on larger beams that provide limited benefits or very small beams that are too impractical for clinical use. SFRT is an area of active research with growing clinical applications and interest. This work aims to lay the groundwork for future small animal studies and inform the development of future clinical trials in humans.","abstract_html":"Spatially fractionated radiation therapy (SFRT) utilizes multiple radiation beams to combine areas of low and high dose within the treatment volume. Organ at risk (OAR) tolerance with SFRT is greater than traditional techniques, with increasing benefits as the beam size decreases. Minibeam radiation therapy (MBRT) is a form of SFRT with beam sizes on the order of 1 mm, which is achievable utilizing conventional treatment techniques, but MBRT has only recently been used in the treatment of humans. The primary objectives of this work are to develop a system to deliver minibeam radiation therapy (MBRT) using a commercially available small animal research radiation therapy platform, perform cell survival studies comparing the survival of cells irradiated with both MBRT and broad beam (BB) dose delivery, and complete an in vivo treatment planning study to determine the dosimetric differences of different MBRT treatment delivery techniques. Most work in SFRT has focused on larger beams that provide limited benefits or very small beams that are too impractical for clinical use. SFRT is an area of active research with growing clinical applications and interest. This work aims to lay the groundwork for future small animal studies and inform the development of future clinical trials in humans.","abstract_has_math":false,"creators":["Herchko, Steven"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Wang, C.-K. Chris"],"committee_chairs":[],"committee_members":["Biegalski, Steven","Dewji, Shaheen","Beltran, Chris","De Araujo Farias, Virginea"],"year":2024,"date_issued":"2024-12-03","date_published":"2024-12-03","updated_at":"2026-11-19T04:59:49Z","subjects":["Spatially fractionated radiation therapy","Minibeam radiation therapy","Monte Carlo simulations, Cell survival"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/76943","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/76943","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F76943","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Wang, C.-K. Chris"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Biegalski, Steven","Dewji, Shaheen","Beltran, Chris","De Araujo Farias, Virginea"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","George W. Woodruff School of Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Herchko, Steven"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-01-15T13:55:54Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-01-15T13:55:54Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2024-12"]},{"key":"dc:date.issued","label":"Date","values":["2024-12-03"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2024"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2025-01-15T13:55:55Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["71d23899-d6d4-4d7f-b9bc-d30323a6f442"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Nuclear Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","c01ff908-c25f-439b-bf10-a074ed886bb7"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["b2bc2e12-2afc-4a4d-bf4c-0ce7832bcefe"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Medical Physics"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Spatially fractionated radiation therapy","Minibeam radiation therapy","Monte Carlo simulations, Cell survival"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/76943"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Spatially fractionated radiation therapy (SFRT) utilizes multiple radiation beams to combine areas of low and high dose within the treatment volume. Organ at risk (OAR) tolerance with SFRT is greater than traditional techniques, with increasing benefits as the beam size decreases. Minibeam radiation therapy (MBRT) is a form of SFRT with beam sizes on the order of 1 mm, which is achievable utilizing conventional treatment techniques, but MBRT has only recently been used in the treatment of humans. The primary objectives of this work are to develop a system to deliver minibeam radiation therapy (MBRT) using a commercially available small animal research radiation therapy platform, perform cell survival studies comparing the survival of cells irradiated with both MBRT and broad beam (BB) dose delivery, and complete an in vivo treatment planning study to determine the dosimetric differences of different MBRT treatment delivery techniques. Most work in SFRT has focused on larger beams that provide limited benefits or very small beams that are too impractical for clinical use. SFRT is an area of active research with growing clinical applications and interest. This work aims to lay the groundwork for future small animal studies and inform the development of future clinical trials in humans."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Development of a Minibeam Delivery System for Use with a Radiation Therapy Research Platform"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Wang, C.-K. Chris"],"dc:contributor.committeemember":["Biegalski, Steven","Dewji, Shaheen","Beltran, Chris","De Araujo Farias, Virginea"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["College of Engineering","George W. Woodruff School of Mechanical Engineering"],"dc:creator":["Herchko, Steven"],"dc:date.accessioned":["2025-01-15T13:55:54Z"],"dc:date.available":["2025-01-15T13:55:54Z"],"dc:date.created":["2024-12"],"dc:date.issued":["2024-12-03"],"dc:date.submitted":["December 2024"],"dc:date.updated":["2025-01-15T13:55:55Z"],"dc:description.abstract":["Spatially fractionated radiation therapy (SFRT) utilizes multiple radiation beams to combine areas of low and high dose within the treatment volume. Organ at risk (OAR) tolerance with SFRT is greater than traditional techniques, with increasing benefits as the beam size decreases. Minibeam radiation therapy (MBRT) is a form of SFRT with beam sizes on the order of 1 mm, which is achievable utilizing conventional treatment techniques, but MBRT has only recently been used in the treatment of humans. The primary objectives of this work are to develop a system to deliver minibeam radiation therapy (MBRT) using a commercially available small animal research radiation therapy platform, perform cell survival studies comparing the survival of cells irradiated with both MBRT and broad beam (BB) dose delivery, and complete an in vivo treatment planning study to determine the dosimetric differences of different MBRT treatment delivery techniques. Most work in SFRT has focused on larger beams that provide limited benefits or very small beams that are too impractical for clinical use. SFRT is an area of active research with growing clinical applications and interest. This work aims to lay the groundwork for future small animal studies and inform the development of future clinical trials in humans."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/76943"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["71d23899-d6d4-4d7f-b9bc-d30323a6f442"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Nuclear Engineering"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","c01ff908-c25f-439b-bf10-a074ed886bb7"],"dc:relation.seriesentity":["b2bc2e12-2afc-4a4d-bf4c-0ce7832bcefe"],"dc:subject":["Spatially fractionated radiation therapy","Minibeam radiation therapy","Monte Carlo simulations, Cell survival"],"dc:title":["Development of a Minibeam Delivery System for Use with a Radiation Therapy Research Platform"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"],"thesis:degree_program":["Medical Physics"]},"updated_at":"2026-11-19T04:59:49Z"}