{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/76998"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/76998","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Assessing viscoelastic properties of skeletal muscle using shear wave elasticity imaging","abstract":"Understanding muscle mechanics is critical for studying the progression of neuromuscular disorders such as Duchenne muscular dystrophy (DMD) and recovery from acute muscle injuries. Despite advancements in diagnostic and therapeutic techniques, noninvasive quantification of mechanical changes remains a challenge. Ultrasound shear wave elastography (SWE) offers a real-time, quantitative method to assess tissue viscoelastic properties, addressing this critical need. This dissertation applies SWE to preclinical models to investigate muscle mechanics, focusing on respiratory and limb muscles in the contexts of DMD and cryo-injury. In the diaphragm, longitudinal assessments uncovered viscoelastic changes across early- and late-stage DMD, highlighting disease progression. Additionally, microneedle applications were examined as a preliminary investigation into potential therapeutic interventions. In limb muscles, a cryo-injury model revealed distinct recovery dynamics, with dystrophic mice showing delayed and incomplete healing compared to wild-type mice. By combining SWE with histological and functional evaluations, this research establishes SWE as a valuable tool for advancing muscle research. The findings bridge gaps between preclinical studies and potential clinical applications, laying the groundwork for translational advancements in the diagnosis and management of muscle-related pathologies.","abstract_html":"Understanding muscle mechanics is critical for studying the progression of neuromuscular disorders such as Duchenne muscular dystrophy (DMD) and recovery from acute muscle injuries. Despite advancements in diagnostic and therapeutic techniques, noninvasive quantification of mechanical changes remains a challenge. Ultrasound shear wave elastography (SWE) offers a real-time, quantitative method to assess tissue viscoelastic properties, addressing this critical need. This dissertation applies SWE to preclinical models to investigate muscle mechanics, focusing on respiratory and limb muscles in the contexts of DMD and cryo-injury. In the diaphragm, longitudinal assessments uncovered viscoelastic changes across early- and late-stage DMD, highlighting disease progression. Additionally, microneedle applications were examined as a preliminary investigation into potential therapeutic interventions. In limb muscles, a cryo-injury model revealed distinct recovery dynamics, with dystrophic mice showing delayed and incomplete healing compared to wild-type mice. By combining SWE with histological and functional evaluations, this research establishes SWE as a valuable tool for advancing muscle research. The findings bridge gaps between preclinical studies and potential clinical applications, laying the groundwork for translational advancements in the diagnosis and management of muscle-related pathologies.","abstract_has_math":false,"creators":["Lee, Jeehyun"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Emelianov, Stanislav"],"committee_chairs":[],"committee_members":["Arvanitis, Costas","García, Andrés","Jang, Young","Lindsey, Brooks"],"year":2024,"date_issued":"2024-12-08","date_published":"2024-12-08","updated_at":"2026-11-19T03:53:32Z","subjects":["Ultrasound","Shear wave elastography","Muscular Dystrophy","DMD"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/76998","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/76998","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F76998","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Emelianov, Stanislav"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Arvanitis, Costas","García, Andrés","Jang, Young","Lindsey, Brooks"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","School of Electrical and Computer Engineering"]},{"key":"dc:creator","label":"Author","values":["Lee, Jeehyun"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-01-15T14:02:08Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-01-15T14:02:08Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2024-12"]},{"key":"dc:date.issued","label":"Date","values":["2024-12-08"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2024"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2025-01-15T14:02:09Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["0191ee0f-a916-4fb2-ba53-c4d82a3fafa7"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","5b7adef2-447c-4270-b9fc-846bd76f80f2"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Electrical and Computer Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Ultrasound","Shear wave elastography","Muscular Dystrophy","DMD"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/76998"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Understanding muscle mechanics is critical for studying the progression of neuromuscular disorders such as Duchenne muscular dystrophy (DMD) and recovery from acute muscle injuries. Despite advancements in diagnostic and therapeutic techniques, noninvasive quantification of mechanical changes remains a challenge. Ultrasound shear wave elastography (SWE) offers a real-time, quantitative method to assess tissue viscoelastic properties, addressing this critical need. This dissertation applies SWE to preclinical models to investigate muscle mechanics, focusing on respiratory and limb muscles in the contexts of DMD and cryo-injury. In the diaphragm, longitudinal assessments uncovered viscoelastic changes across early- and late-stage DMD, highlighting disease progression. Additionally, microneedle applications were examined as a preliminary investigation into potential therapeutic interventions. In limb muscles, a cryo-injury model revealed distinct recovery dynamics, with dystrophic mice showing delayed and incomplete healing compared to wild-type mice. By combining SWE with histological and functional evaluations, this research establishes SWE as a valuable tool for advancing muscle research. The findings bridge gaps between preclinical studies and potential clinical applications, laying the groundwork for translational advancements in the diagnosis and management of muscle-related pathologies."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Assessing viscoelastic properties of skeletal muscle using shear wave elasticity imaging"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Emelianov, Stanislav"],"dc:contributor.committeemember":["Arvanitis, Costas","García, Andrés","Jang, Young","Lindsey, Brooks"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["College of Engineering","School of Electrical and Computer Engineering"],"dc:creator":["Lee, Jeehyun"],"dc:date.accessioned":["2025-01-15T14:02:08Z"],"dc:date.available":["2025-01-15T14:02:08Z"],"dc:date.created":["2024-12"],"dc:date.issued":["2024-12-08"],"dc:date.submitted":["December 2024"],"dc:date.updated":["2025-01-15T14:02:09Z"],"dc:description.abstract":["Understanding muscle mechanics is critical for studying the progression of neuromuscular disorders such as Duchenne muscular dystrophy (DMD) and recovery from acute muscle injuries. Despite advancements in diagnostic and therapeutic techniques, noninvasive quantification of mechanical changes remains a challenge. Ultrasound shear wave elastography (SWE) offers a real-time, quantitative method to assess tissue viscoelastic properties, addressing this critical need. This dissertation applies SWE to preclinical models to investigate muscle mechanics, focusing on respiratory and limb muscles in the contexts of DMD and cryo-injury. In the diaphragm, longitudinal assessments uncovered viscoelastic changes across early- and late-stage DMD, highlighting disease progression. Additionally, microneedle applications were examined as a preliminary investigation into potential therapeutic interventions. In limb muscles, a cryo-injury model revealed distinct recovery dynamics, with dystrophic mice showing delayed and incomplete healing compared to wild-type mice. By combining SWE with histological and functional evaluations, this research establishes SWE as a valuable tool for advancing muscle research. The findings bridge gaps between preclinical studies and potential clinical applications, laying the groundwork for translational advancements in the diagnosis and management of muscle-related pathologies."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/76998"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["0191ee0f-a916-4fb2-ba53-c4d82a3fafa7"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","5b7adef2-447c-4270-b9fc-846bd76f80f2"],"dc:relation.seriesentity":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"],"dc:subject":["Ultrasound","Shear wave elastography","Muscular Dystrophy","DMD"],"dc:title":["Assessing viscoelastic properties of skeletal muscle using shear wave elasticity imaging"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"],"thesis:degree_program":["Electrical and Computer Engineering"]},"updated_at":"2026-11-19T03:53:32Z"}