{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/77740"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/77740","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Advanced Techniques in UV Microscopy: Integrating Deep Learning for Autofocusing, Whole Slide Imaging Optimization, and Spicule Detection in Bone Marrow Aspirations","abstract":"Deep-ultraviolet (UV) microscopy enables label-free, high-resolution, quantitative molecular imaging and enables unique applications in biomedicine. This is achieved by leveraging the unique absorption of different biomolecules in the deep UV spectrum (200~400nm). While UV microscopy has historically been limited by phototoxicity concerns, recent advances in UV imaging hardware have allowed for live cell imaging for more than six hours with no observable photodamage. This proposal aims to expand the capabilities of UV microscopy for biomedical applications using CNN based architectures. Initially, we will employ a custom benchtop multispectral microscope for single-shot autofocusing. Subsequently, we will utilize a lowcost compact UV microscope for automated whole-slide imaging, incorporating singleshot autofocusing as well. Additionally, the compact UV microscope will be employed for automated spicule detection in bone marrow aspirations to enable an untrained clinician to use the device.","abstract_html":"Deep-ultraviolet (UV) microscopy enables label-free, high-resolution, quantitative molecular imaging and enables unique applications in biomedicine. This is achieved by leveraging the unique absorption of different biomolecules in the deep UV spectrum (200~400nm). While UV microscopy has historically been limited by phototoxicity concerns, recent advances in UV imaging hardware have allowed for live cell imaging for more than six hours with no observable photodamage. This proposal aims to expand the capabilities of UV microscopy for biomedical applications using CNN based architectures. Initially, we will employ a custom benchtop multispectral microscope for single-shot autofocusing. Subsequently, we will utilize a lowcost compact UV microscope for automated whole-slide imaging, incorporating singleshot autofocusing as well. Additionally, the compact UV microscope will be employed for automated spicule detection in bone marrow aspirations to enable an untrained clinician to use the device.","abstract_has_math":false,"creators":["Subramanian, Ajay Rajaraman"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Biomedical Engineering (Joint GT/Emory Department)","school":null,"contributors":[],"advisors":["Robles, Francisco E."],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024-05-02","date_published":"2024-05-02","updated_at":"2026-11-19T06:06:27Z","subjects":["Deep UV microscopy","Convolutional Neural Network","YOLOv7"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/77740","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/77740","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F77740","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Robles, Francisco E."]},{"key":"dc:contributor.department","label":"Department","values":["Biomedical Engineering (Joint GT/Emory Department)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","Wallace H. Coulter Department of Biomedical Engineering"]},{"key":"dc:creator","label":"Author","values":["Subramanian, Ajay Rajaraman"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-06-23T15:15:55Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-06-23T15:15:55Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2024-05"]},{"key":"dc:date.issued","label":"Date","values":["2024-05-02"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2024"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2025-06-23T15:15:55Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["0bc330c1-6b74-46c6-a806-e4626b7760f7"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","da59be3c-3d0a-41da-91b9-ebe2ecc83b66"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Biomedical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Deep UV microscopy","Convolutional Neural Network","YOLOv7"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/77740"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Deep-ultraviolet (UV) microscopy enables label-free, high-resolution, quantitative molecular imaging and enables unique applications in biomedicine. This is achieved by leveraging the unique absorption of different biomolecules in the deep UV spectrum (200~400nm). While UV microscopy has historically been limited by phototoxicity concerns, recent advances in UV imaging hardware have allowed for live cell imaging for more than six hours with no observable photodamage. This proposal aims to expand the capabilities of UV microscopy for biomedical applications using CNN based architectures. Initially, we will employ a custom benchtop multispectral microscope for single-shot autofocusing. Subsequently, we will utilize a lowcost compact UV microscope for automated whole-slide imaging, incorporating singleshot autofocusing as well. Additionally, the compact UV microscope will be employed for automated spicule detection in bone marrow aspirations to enable an untrained clinician to use the device."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Advanced Techniques in UV Microscopy: Integrating Deep Learning for Autofocusing, Whole Slide Imaging Optimization, and Spicule Detection in Bone Marrow Aspirations"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Robles, Francisco E."],"dc:contributor.department":["Biomedical Engineering (Joint GT/Emory Department)"],"dc:contributor.other":["College of Engineering","Wallace H. Coulter Department of Biomedical Engineering"],"dc:creator":["Subramanian, Ajay Rajaraman"],"dc:date.accessioned":["2025-06-23T15:15:55Z"],"dc:date.available":["2025-06-23T15:15:55Z"],"dc:date.created":["2024-05"],"dc:date.issued":["2024-05-02"],"dc:date.submitted":["May 2024"],"dc:date.updated":["2025-06-23T15:15:55Z"],"dc:description.abstract":["Deep-ultraviolet (UV) microscopy enables label-free, high-resolution, quantitative molecular imaging and enables unique applications in biomedicine. This is achieved by leveraging the unique absorption of different biomolecules in the deep UV spectrum (200~400nm). While UV microscopy has historically been limited by phototoxicity concerns, recent advances in UV imaging hardware have allowed for live cell imaging for more than six hours with no observable photodamage. This proposal aims to expand the capabilities of UV microscopy for biomedical applications using CNN based architectures. Initially, we will employ a custom benchtop multispectral microscope for single-shot autofocusing. Subsequently, we will utilize a lowcost compact UV microscope for automated whole-slide imaging, incorporating singleshot autofocusing as well. Additionally, the compact UV microscope will be employed for automated spicule detection in bone marrow aspirations to enable an untrained clinician to use the device."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/77740"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["0bc330c1-6b74-46c6-a806-e4626b7760f7"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","da59be3c-3d0a-41da-91b9-ebe2ecc83b66"],"dc:subject":["Deep UV microscopy","Convolutional Neural Network","YOLOv7"],"dc:title":["Advanced Techniques in UV Microscopy: Integrating Deep Learning for Autofocusing, Whole Slide Imaging Optimization, and Spicule Detection in Bone Marrow Aspirations"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"],"thesis:degree_program":["Biomedical Engineering"]},"updated_at":"2026-11-19T06:06:27Z"}