{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/77841"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/77841","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"A Novel ‘In-Silico’ Method for Modeling the RBE of Clinical Proton Beams","abstract":"This thesis explores the variability of RBE in proton therapy, highlighting its dependence not only on LET but also on various biological factors. Employing a novel approach, this study first conducts a Monte Carlo simulation of a clinical SOBP (with parameters from the Emory Proton Therapy Center) to obtain the energy spectrum of primary protons at multiple key depths in a water phantom. The energy spectrum data then served to fetch the DNA damage data from a DNA damage data library, which was pre-calculated by using TOPAS-nBio code simulating proton tracks randomly traversing a cell nucleus. The use of pre-calculated DNA damage data library significantly speeds up computation and allows for rapid assembly of the proton-induced DNA damage data on cell-by-cell basis and for various absorbed doses. Subsequent analysis through the MEDRAS-MC code, simulating DNA damage repair, enables the generation of cell survival curves for each depth, allowing for the variation of RBE (with respect to depth) to be assessed. This mechanistic approach provides a scalable methodology for assessing the RBE of clinical proton beams, achieving a balance between detail and practical applicability.tail and practical applicability.","abstract_html":"This thesis explores the variability of RBE in proton therapy, highlighting its dependence not only on LET but also on various biological factors. Employing a novel approach, this study first conducts a Monte Carlo simulation of a clinical SOBP (with parameters from the Emory Proton Therapy Center) to obtain the energy spectrum of primary protons at multiple key depths in a water phantom. The energy spectrum data then served to fetch the DNA damage data from a DNA damage data library, which was pre-calculated by using TOPAS-nBio code simulating proton tracks randomly traversing a cell nucleus. The use of pre-calculated DNA damage data library significantly speeds up computation and allows for rapid assembly of the proton-induced DNA damage data on cell-by-cell basis and for various absorbed doses. Subsequent analysis through the MEDRAS-MC code, simulating DNA damage repair, enables the generation of cell survival curves for each depth, allowing for the variation of RBE (with respect to depth) to be assessed. This mechanistic approach provides a scalable methodology for assessing the RBE of clinical proton beams, achieving a balance between detail and practical applicability.tail and practical applicability.","abstract_has_math":false,"creators":["O'Dell, Alexander R."],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Wang, C.-K. Chris"],"committee_chairs":[],"committee_members":["Biegalski, Steven","Lin, Liyong","Agasthya, Greeshma"],"year":2025,"date_issued":"2025-04-22","date_published":"2025-04-22","updated_at":"2026-11-19T04:52:28Z","subjects":["TOPAS","TOPAS-nBio","RBE","Proton Therapy","Radiotherapy","Simulation","Monte Carlo"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/77841","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/77841","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F77841","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Wang, C.-K. Chris"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Biegalski, Steven","Lin, Liyong","Agasthya, Greeshma"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","George W. Woodruff School of Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["O'Dell, Alexander R."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-06-23T15:22:16Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-06-23T15:22:16Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-05"]},{"key":"dc:date.issued","label":"Date","values":["2025-04-22"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2025"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2025-06-23T15:22:17Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["71d23899-d6d4-4d7f-b9bc-d30323a6f442"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Medical Physics"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","c01ff908-c25f-439b-bf10-a074ed886bb7"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["3173665c-cfb8-400b-bcf7-8fbfc614e0fb"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Medical Physics"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["TOPAS","TOPAS-nBio","RBE","Proton Therapy","Radiotherapy","Simulation","Monte Carlo"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/77841"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis explores the variability of RBE in proton therapy, highlighting its dependence not only on LET but also on various biological factors. Employing a novel approach, this study first conducts a Monte Carlo simulation of a clinical SOBP (with parameters from the Emory Proton Therapy Center) to obtain the energy spectrum of primary protons at multiple key depths in a water phantom. The energy spectrum data then served to fetch the DNA damage data from a DNA damage data library, which was pre-calculated by using TOPAS-nBio code simulating proton tracks randomly traversing a cell nucleus. The use of pre-calculated DNA damage data library significantly speeds up computation and allows for rapid assembly of the proton-induced DNA damage data on cell-by-cell basis and for various absorbed doses. Subsequent analysis through the MEDRAS-MC code, simulating DNA damage repair, enables the generation of cell survival curves for each depth, allowing for the variation of RBE (with respect to depth) to be assessed. This mechanistic approach provides a scalable methodology for assessing the RBE of clinical proton beams, achieving a balance between detail and practical applicability.tail and practical applicability."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A Novel ‘In-Silico’ Method for Modeling the RBE of Clinical Proton Beams"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Wang, C.-K. Chris"],"dc:contributor.committeemember":["Biegalski, Steven","Lin, Liyong","Agasthya, Greeshma"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["College of Engineering","George W. Woodruff School of Mechanical Engineering"],"dc:creator":["O'Dell, Alexander R."],"dc:date.accessioned":["2025-06-23T15:22:16Z"],"dc:date.available":["2025-06-23T15:22:16Z"],"dc:date.created":["2025-05"],"dc:date.issued":["2025-04-22"],"dc:date.submitted":["May 2025"],"dc:date.updated":["2025-06-23T15:22:17Z"],"dc:description.abstract":["This thesis explores the variability of RBE in proton therapy, highlighting its dependence not only on LET but also on various biological factors. Employing a novel approach, this study first conducts a Monte Carlo simulation of a clinical SOBP (with parameters from the Emory Proton Therapy Center) to obtain the energy spectrum of primary protons at multiple key depths in a water phantom. The energy spectrum data then served to fetch the DNA damage data from a DNA damage data library, which was pre-calculated by using TOPAS-nBio code simulating proton tracks randomly traversing a cell nucleus. The use of pre-calculated DNA damage data library significantly speeds up computation and allows for rapid assembly of the proton-induced DNA damage data on cell-by-cell basis and for various absorbed doses. Subsequent analysis through the MEDRAS-MC code, simulating DNA damage repair, enables the generation of cell survival curves for each depth, allowing for the variation of RBE (with respect to depth) to be assessed. This mechanistic approach provides a scalable methodology for assessing the RBE of clinical proton beams, achieving a balance between detail and practical applicability.tail and practical applicability."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/77841"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["71d23899-d6d4-4d7f-b9bc-d30323a6f442"],"dc:relation.ispartofseries":["Master of Science in Medical Physics"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","c01ff908-c25f-439b-bf10-a074ed886bb7"],"dc:relation.seriesentity":["3173665c-cfb8-400b-bcf7-8fbfc614e0fb"],"dc:subject":["TOPAS","TOPAS-nBio","RBE","Proton Therapy","Radiotherapy","Simulation","Monte Carlo"],"dc:title":["A Novel ‘In-Silico’ Method for Modeling the RBE of Clinical Proton Beams"],"dc:type":["Text","Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"],"thesis:degree_program":["Medical Physics"]},"updated_at":"2026-11-19T04:52:28Z"}