{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/77892"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/77892","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Single-Cell Impedance Cytometry for the Control of Single-Cell Electroporation in a Flow-Through Device","abstract":"Cell therapies have shown great promise in treating diseases such as CAR-T cells for blood cancers. Manufacturing these therapies presents considerable challenges and costs. These include quality of donor source material, transfection of cells, and controlling and measuring the quality of the product. Current therapies often transfect cells by viral vectors which are costly, have payload limitations, are difficult to target specific cells with, and present safety concerns due to immunogenicity and oncogenicity. A microfluidic single-cell electroporation device and scheme was made to address these concerns. Electroporation is an alternative non-viral method of transfection that is inexpensive and non-immunogenic. Additionally, it is applicable to different cell types or delivery payloads including larger payloads (e.g. CRISPR-Cas). However, electroporation can cause significant cell death, toxicity, and/or low delivery efficiencies. This microfluidic device electronically measures properties of single cells and applies an electroporation voltage based on that measurement. This feedback is demonstrated by selectively delivering to only certain cell types in a mixture of cell types. Further efforts were made to create a PDMS-on-glass version of the device to be compatible with microscopy imaging, as well as producing functional CAR-T cells with the device.","abstract_html":"Cell therapies have shown great promise in treating diseases such as CAR-T cells for blood cancers. Manufacturing these therapies presents considerable challenges and costs. These include quality of donor source material, transfection of cells, and controlling and measuring the quality of the product. Current therapies often transfect cells by viral vectors which are costly, have payload limitations, are difficult to target specific cells with, and present safety concerns due to immunogenicity and oncogenicity. A microfluidic single-cell electroporation device and scheme was made to address these concerns. Electroporation is an alternative non-viral method of transfection that is inexpensive and non-immunogenic. Additionally, it is applicable to different cell types or delivery payloads including larger payloads (e.g. CRISPR-Cas). However, electroporation can cause significant cell death, toxicity, and/or low delivery efficiencies. This microfluidic device electronically measures properties of single cells and applies an electroporation voltage based on that measurement. This feedback is demonstrated by selectively delivering to only certain cell types in a mixture of cell types. Further efforts were made to create a PDMS-on-glass version of the device to be compatible with microscopy imaging, as well as producing functional CAR-T cells with the device.","abstract_has_math":false,"creators":["Rudge, Josiah"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Sarkar, Aniruddh"],"committee_chairs":[],"committee_members":["Kwong, Gabe","Sarioglu, Fatih","Blazeck, John","Myers, David"],"year":2025,"date_issued":"2025-04-29","date_published":"2025-04-29","updated_at":"2026-11-19T06:02:32Z","subjects":["Single cell","electroporation","impedance cytometry"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/77892","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/77892","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F77892","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Sarkar, Aniruddh"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Kwong, Gabe","Sarioglu, Fatih","Blazeck, John","Myers, David"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","School of Electrical and Computer Engineering"]},{"key":"dc:creator","label":"Author","values":["Rudge, Josiah"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-06-23T15:25:12Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-06-23T15:25:12Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-05"]},{"key":"dc:date.issued","label":"Date","values":["2025-04-29"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2025"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2025-06-23T15:25:12Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["ace47750-bfad-4c09-8198-11ce4920c8ed"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","5b7adef2-447c-4270-b9fc-846bd76f80f2"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Bioengineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Single cell","electroporation","impedance cytometry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/77892"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Cell therapies have shown great promise in treating diseases such as CAR-T cells for blood cancers. Manufacturing these therapies presents considerable challenges and costs. These include quality of donor source material, transfection of cells, and controlling and measuring the quality of the product. Current therapies often transfect cells by viral vectors which are costly, have payload limitations, are difficult to target specific cells with, and present safety concerns due to immunogenicity and oncogenicity. A microfluidic single-cell electroporation device and scheme was made to address these concerns. Electroporation is an alternative non-viral method of transfection that is inexpensive and non-immunogenic. Additionally, it is applicable to different cell types or delivery payloads including larger payloads (e.g. CRISPR-Cas). However, electroporation can cause significant cell death, toxicity, and/or low delivery efficiencies. This microfluidic device electronically measures properties of single cells and applies an electroporation voltage based on that measurement. This feedback is demonstrated by selectively delivering to only certain cell types in a mixture of cell types. Further efforts were made to create a PDMS-on-glass version of the device to be compatible with microscopy imaging, as well as producing functional CAR-T cells with the device."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Single-Cell Impedance Cytometry for the Control of Single-Cell Electroporation in a Flow-Through Device"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Sarkar, Aniruddh"],"dc:contributor.committeemember":["Kwong, Gabe","Sarioglu, Fatih","Blazeck, John","Myers, David"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["College of Engineering","School of Electrical and Computer Engineering"],"dc:creator":["Rudge, Josiah"],"dc:date.accessioned":["2025-06-23T15:25:12Z"],"dc:date.available":["2025-06-23T15:25:12Z"],"dc:date.created":["2025-05"],"dc:date.issued":["2025-04-29"],"dc:date.submitted":["May 2025"],"dc:date.updated":["2025-06-23T15:25:12Z"],"dc:description.abstract":["Cell therapies have shown great promise in treating diseases such as CAR-T cells for blood cancers. Manufacturing these therapies presents considerable challenges and costs. These include quality of donor source material, transfection of cells, and controlling and measuring the quality of the product. Current therapies often transfect cells by viral vectors which are costly, have payload limitations, are difficult to target specific cells with, and present safety concerns due to immunogenicity and oncogenicity. A microfluidic single-cell electroporation device and scheme was made to address these concerns. Electroporation is an alternative non-viral method of transfection that is inexpensive and non-immunogenic. Additionally, it is applicable to different cell types or delivery payloads including larger payloads (e.g. CRISPR-Cas). However, electroporation can cause significant cell death, toxicity, and/or low delivery efficiencies. This microfluidic device electronically measures properties of single cells and applies an electroporation voltage based on that measurement. This feedback is demonstrated by selectively delivering to only certain cell types in a mixture of cell types. Further efforts were made to create a PDMS-on-glass version of the device to be compatible with microscopy imaging, as well as producing functional CAR-T cells with the device."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/77892"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["ace47750-bfad-4c09-8198-11ce4920c8ed"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","5b7adef2-447c-4270-b9fc-846bd76f80f2"],"dc:subject":["Single cell","electroporation","impedance cytometry"],"dc:title":["Single-Cell Impedance Cytometry for the Control of Single-Cell Electroporation in a Flow-Through Device"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"],"thesis:degree_program":["Bioengineering"]},"updated_at":"2026-11-19T06:02:32Z"}