{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/78552"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/78552","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Non-invasive Arc Duration Measurement Based on Different Physical Emissions","abstract":"The objective of this research is to develop a robust online non-invasive arc duration measurement method in the substation, which is a critical factor for circuit breaker online contact erosion estimation and implementation of condition-based and reliability-centered maintenance practices. In this research, different arc duration measurement methods using various physical signals, including very-low-frequency and low-frequency magnetic field, vibration, and sound signals are proposed. Each method, however, has its limitations. For the method based on very-low-frequency and low-frequency magnetic field, although the waveform signatures can indicate the arc initiation and extinction time, their susceptibility to contact geometry changes caused by contact erosion restricts the application scenarios of this method. The domain-adaptive method based on vibration and sound signals, on the other hand, can achieve a high accuracy (below 0.2 ms) comparable to existing techniques and exhibit robustness against noise interference and domain shift, which existing methods lack. However, the method requires representative substation data to train neural networks. Eventually, a decision-level fusion strategy is proposed. This strategy can combine existing and proposed methods to address the limitations that cannot be solved by a single method individually and enhance the accuracy and robustness of arc duration measurement in the substation.","abstract_html":"The objective of this research is to develop a robust online non-invasive arc duration measurement method in the substation, which is a critical factor for circuit breaker online contact erosion estimation and implementation of condition-based and reliability-centered maintenance practices. In this research, different arc duration measurement methods using various physical signals, including very-low-frequency and low-frequency magnetic field, vibration, and sound signals are proposed. Each method, however, has its limitations. For the method based on very-low-frequency and low-frequency magnetic field, although the waveform signatures can indicate the arc initiation and extinction time, their susceptibility to contact geometry changes caused by contact erosion restricts the application scenarios of this method. The domain-adaptive method based on vibration and sound signals, on the other hand, can achieve a high accuracy (below 0.2 ms) comparable to existing techniques and exhibit robustness against noise interference and domain shift, which existing methods lack. However, the method requires representative substation data to train neural networks. Eventually, a decision-level fusion strategy is proposed. This strategy can combine existing and proposed methods to address the limitations that cannot be solved by a single method individually and enhance the accuracy and robustness of arc duration measurement in the substation.","abstract_has_math":false,"creators":["Guo, Ning"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Graber, Lukas"],"committee_chairs":[],"committee_members":["Cohen, Morris B.","Beyah, Raheem A.","Grijalva, Santiage C.","Tien, Iris"],"year":2024,"date_issued":"2024-06-26","date_published":"2024-06-26","updated_at":"2026-11-19T04:26:01Z","subjects":["Circuit Breaker","Arc Duration Measurement"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/78552","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/78552","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F78552","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Graber, Lukas"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Cohen, Morris B.","Beyah, Raheem A.","Grijalva, Santiage C.","Tien, Iris"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","School of Electrical and Computer Engineering"]},{"key":"dc:creator","label":"Author","values":["Guo, Ning"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-08-15T12:28:35Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-08-15T12:28:35Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2024-08"]},{"key":"dc:date.issued","label":"Date","values":["2024-06-26"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2024"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2025-08-15T12:28:37Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["ef92cc42-4de7-450b-a0a3-91822c1af6de"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","5b7adef2-447c-4270-b9fc-846bd76f80f2"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Electrical and Computer Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Circuit Breaker","Arc Duration Measurement"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/78552"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The objective of this research is to develop a robust online non-invasive arc duration measurement method in the substation, which is a critical factor for circuit breaker online contact erosion estimation and implementation of condition-based and reliability-centered maintenance practices. In this research, different arc duration measurement methods using various physical signals, including very-low-frequency and low-frequency magnetic field, vibration, and sound signals are proposed. Each method, however, has its limitations. For the method based on very-low-frequency and low-frequency magnetic field, although the waveform signatures can indicate the arc initiation and extinction time, their susceptibility to contact geometry changes caused by contact erosion restricts the application scenarios of this method. The domain-adaptive method based on vibration and sound signals, on the other hand, can achieve a high accuracy (below 0.2 ms) comparable to existing techniques and exhibit robustness against noise interference and domain shift, which existing methods lack. However, the method requires representative substation data to train neural networks. Eventually, a decision-level fusion strategy is proposed. This strategy can combine existing and proposed methods to address the limitations that cannot be solved by a single method individually and enhance the accuracy and robustness of arc duration measurement in the substation."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Non-invasive Arc Duration Measurement Based on Different Physical Emissions"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Graber, Lukas"],"dc:contributor.committeemember":["Cohen, Morris B.","Beyah, Raheem A.","Grijalva, Santiage C.","Tien, Iris"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["College of Engineering","School of Electrical and Computer Engineering"],"dc:creator":["Guo, Ning"],"dc:date.accessioned":["2025-08-15T12:28:35Z"],"dc:date.available":["2025-08-15T12:28:35Z"],"dc:date.created":["2024-08"],"dc:date.issued":["2024-06-26"],"dc:date.submitted":["August 2024"],"dc:date.updated":["2025-08-15T12:28:37Z"],"dc:description.abstract":["The objective of this research is to develop a robust online non-invasive arc duration measurement method in the substation, which is a critical factor for circuit breaker online contact erosion estimation and implementation of condition-based and reliability-centered maintenance practices. In this research, different arc duration measurement methods using various physical signals, including very-low-frequency and low-frequency magnetic field, vibration, and sound signals are proposed. Each method, however, has its limitations. For the method based on very-low-frequency and low-frequency magnetic field, although the waveform signatures can indicate the arc initiation and extinction time, their susceptibility to contact geometry changes caused by contact erosion restricts the application scenarios of this method. The domain-adaptive method based on vibration and sound signals, on the other hand, can achieve a high accuracy (below 0.2 ms) comparable to existing techniques and exhibit robustness against noise interference and domain shift, which existing methods lack. However, the method requires representative substation data to train neural networks. Eventually, a decision-level fusion strategy is proposed. This strategy can combine existing and proposed methods to address the limitations that cannot be solved by a single method individually and enhance the accuracy and robustness of arc duration measurement in the substation."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/78552"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["ef92cc42-4de7-450b-a0a3-91822c1af6de"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","5b7adef2-447c-4270-b9fc-846bd76f80f2"],"dc:subject":["Circuit Breaker","Arc Duration Measurement"],"dc:title":["Non-invasive Arc Duration Measurement Based on Different Physical Emissions"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"],"thesis:degree_program":["Electrical and Computer Engineering"]},"updated_at":"2026-11-19T04:26:01Z"}