{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/78568"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/78568","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"A Smart Prosthesis Socket Liner to Address Factors That Lead to Prosthesis Abandonment","abstract":"The development and characterization of the smart prosthesis socket liner, a soft-robotic prosthesis liner, was presented. This novel robotic system was intended to improve the quality of life for transradial amputees and strived to decrease the rate of prosthesis abandonment. This novel socket liner used closed-loop pneumatic control systems to regulate the fit of the human-socket interface and accommodate residual-limb volume fluctuations. Multiple real-time classification algorithms were developed to prescribe the desired fit of the pneumatic control system depending on user activity. The inputs for the classifiers were a fusion of data from two inertial measurement units and the state changes of the soft-pneumatic actuators. The classifiers sorted the input features into three categories of upper-extremity activities and prescribed the desired fit of the liner. Additional flexible fabric-based heat-dissipation and interface layers were implemented into the liner system to remove heat from the human-socket interface and measure the temperature of the interface. The heat-dissipation subsystem used a closed-loop water cycle to extract and dissipate heat outside the human-socket interface. These subsystems simultaneously perform their respective goals in the single integrated soft-robotic system. Lastly, the mechanical impedance of the interface between this soft-robotic system and the user was characterized. The effects this mechanical impedance may have on users' ability to track moving targets was discussed. To demonstrate the generalizability of the technology integrated into this novel robotic socket liner, a summary of the ventilation-perfusion vest was discussed. The vest was applied to patients suffering from acute respiratory distress syndrome caused by COVID-19. The vest was shown to improve the oxygenation of these patients.","abstract_html":"The development and characterization of the smart prosthesis socket liner, a soft-robotic prosthesis liner, was presented. This novel robotic system was intended to improve the quality of life for transradial amputees and strived to decrease the rate of prosthesis abandonment. This novel socket liner used closed-loop pneumatic control systems to regulate the fit of the human-socket interface and accommodate residual-limb volume fluctuations. Multiple real-time classification algorithms were developed to prescribe the desired fit of the pneumatic control system depending on user activity. The inputs for the classifiers were a fusion of data from two inertial measurement units and the state changes of the soft-pneumatic actuators. The classifiers sorted the input features into three categories of upper-extremity activities and prescribed the desired fit of the liner. Additional flexible fabric-based heat-dissipation and interface layers were implemented into the liner system to remove heat from the human-socket interface and measure the temperature of the interface. The heat-dissipation subsystem used a closed-loop water cycle to extract and dissipate heat outside the human-socket interface. These subsystems simultaneously perform their respective goals in the single integrated soft-robotic system. Lastly, the mechanical impedance of the interface between this soft-robotic system and the user was characterized. The effects this mechanical impedance may have on users&#x27; ability to track moving targets was discussed. To demonstrate the generalizability of the technology integrated into this novel robotic socket liner, a summary of the ventilation-perfusion vest was discussed. The vest was applied to patients suffering from acute respiratory distress syndrome caused by COVID-19. The vest was shown to improve the oxygenation of these patients.","abstract_has_math":false,"creators":["Ambrose, Alexander B."],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Hammond, Frank L., III","Sawicki, Gregory S."],"committee_chairs":[],"committee_members":["Mazumdar, Ellen Yi Chen","Wheaton, Lewis","Herrin, Kinsey","Tucker, Maegan"],"year":2024,"date_issued":"2024-07-17","date_published":"2024-07-17","updated_at":"2026-11-19T05:49:53Z","subjects":["Soft robotics","Prosthesis socket","COVID-19","Computational fluid dynamics","Steady-state heat transfer"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/78568","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/78568","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F78568","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Hammond, Frank L., III","Sawicki, Gregory S."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Mazumdar, Ellen Yi Chen","Wheaton, Lewis","Herrin, Kinsey","Tucker, Maegan"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","George W. Woodruff School of Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Ambrose, Alexander B."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-08-15T12:30:41Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-08-15T12:30:41Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2024-08"]},{"key":"dc:date.issued","label":"Date","values":["2024-07-17"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2024"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2025-08-15T12:30:42Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["25430b41-a2e6-4931-9877-41bf8c4a6f2a","5cde14d7-341d-4e7c-890b-7792135d0e83"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","c01ff908-c25f-439b-bf10-a074ed886bb7"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Mechanical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Soft robotics","Prosthesis socket","COVID-19","Computational fluid dynamics","Steady-state heat transfer"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/78568"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The development and characterization of the smart prosthesis socket liner, a soft-robotic prosthesis liner, was presented. This novel robotic system was intended to improve the quality of life for transradial amputees and strived to decrease the rate of prosthesis abandonment. This novel socket liner used closed-loop pneumatic control systems to regulate the fit of the human-socket interface and accommodate residual-limb volume fluctuations. Multiple real-time classification algorithms were developed to prescribe the desired fit of the pneumatic control system depending on user activity. The inputs for the classifiers were a fusion of data from two inertial measurement units and the state changes of the soft-pneumatic actuators. The classifiers sorted the input features into three categories of upper-extremity activities and prescribed the desired fit of the liner. Additional flexible fabric-based heat-dissipation and interface layers were implemented into the liner system to remove heat from the human-socket interface and measure the temperature of the interface. The heat-dissipation subsystem used a closed-loop water cycle to extract and dissipate heat outside the human-socket interface. These subsystems simultaneously perform their respective goals in the single integrated soft-robotic system. Lastly, the mechanical impedance of the interface between this soft-robotic system and the user was characterized. The effects this mechanical impedance may have on users' ability to track moving targets was discussed. To demonstrate the generalizability of the technology integrated into this novel robotic socket liner, a summary of the ventilation-perfusion vest was discussed. The vest was applied to patients suffering from acute respiratory distress syndrome caused by COVID-19. The vest was shown to improve the oxygenation of these patients."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A Smart Prosthesis Socket Liner to Address Factors That Lead to Prosthesis Abandonment"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Hammond, Frank L., III","Sawicki, Gregory S."],"dc:contributor.committeemember":["Mazumdar, Ellen Yi Chen","Wheaton, Lewis","Herrin, Kinsey","Tucker, Maegan"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["College of Engineering","George W. Woodruff School of Mechanical Engineering"],"dc:creator":["Ambrose, Alexander B."],"dc:date.accessioned":["2025-08-15T12:30:41Z"],"dc:date.available":["2025-08-15T12:30:41Z"],"dc:date.created":["2024-08"],"dc:date.issued":["2024-07-17"],"dc:date.submitted":["August 2024"],"dc:date.updated":["2025-08-15T12:30:42Z"],"dc:description.abstract":["The development and characterization of the smart prosthesis socket liner, a soft-robotic prosthesis liner, was presented. This novel robotic system was intended to improve the quality of life for transradial amputees and strived to decrease the rate of prosthesis abandonment. This novel socket liner used closed-loop pneumatic control systems to regulate the fit of the human-socket interface and accommodate residual-limb volume fluctuations. Multiple real-time classification algorithms were developed to prescribe the desired fit of the pneumatic control system depending on user activity. The inputs for the classifiers were a fusion of data from two inertial measurement units and the state changes of the soft-pneumatic actuators. The classifiers sorted the input features into three categories of upper-extremity activities and prescribed the desired fit of the liner. Additional flexible fabric-based heat-dissipation and interface layers were implemented into the liner system to remove heat from the human-socket interface and measure the temperature of the interface. The heat-dissipation subsystem used a closed-loop water cycle to extract and dissipate heat outside the human-socket interface. These subsystems simultaneously perform their respective goals in the single integrated soft-robotic system. Lastly, the mechanical impedance of the interface between this soft-robotic system and the user was characterized. The effects this mechanical impedance may have on users' ability to track moving targets was discussed. To demonstrate the generalizability of the technology integrated into this novel robotic socket liner, a summary of the ventilation-perfusion vest was discussed. The vest was applied to patients suffering from acute respiratory distress syndrome caused by COVID-19. The vest was shown to improve the oxygenation of these patients."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/78568"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["25430b41-a2e6-4931-9877-41bf8c4a6f2a","5cde14d7-341d-4e7c-890b-7792135d0e83"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","c01ff908-c25f-439b-bf10-a074ed886bb7"],"dc:subject":["Soft robotics","Prosthesis socket","COVID-19","Computational fluid dynamics","Steady-state heat transfer"],"dc:title":["A Smart Prosthesis Socket Liner to Address Factors That Lead to Prosthesis Abandonment"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"],"thesis:degree_program":["Mechanical Engineering"]},"updated_at":"2026-11-19T05:49:53Z"}