{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/78649"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/78649","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Miniaturized Acousto-Optic Sensor for RF Field Measurement Under MRI","abstract":"RF field measurement under MRI presents a significant measurement challenge. Both components of the RF field, the electric field and the magnetic field, are uniquely important for real-time sensing during an MR-sequence: the electric field contributes to deposited RF power in the tissue, leading to increased tissue temperature, while the magnetic field is used for imaging and localization. Conventional RF field sensors use long electrical conductors for signal transmission, which distort images and contribute to local RF power hot-spots, potentially damaging tissue on or in the patient. Current MRI-compatible sensors employ transduction from electrical to optical signals for RF immune signal transmission, which subverts these issues. However, demonstrated sensors either utilize complex, actively pow- ered components, or rely on large, rigid components for passive sensing, all of which may constrain the device geometry, performance, and application. The feasibility of an acousto-optic (AO) RF field sensor structure based on light inten- sity modulation via an antenna-coupled piezoelectric transducer modulating a fiber-Bragg grating (FBG) was demonstrated earlier. This work develops and validates an end-to-end model of the AO sensor to enable design optimization, and a fabrication process based on conformal piezo-composite polymer transducers over optical fibers. The use of coaxial piezoelectric transducers increases the acoustic coupling efficiency and minimize the size of the sensor for seamless integration on interventional MRI catheters as compared to pla- nar and bulky piezo crystals glued to optical fibers. Sensors are designed and fabricated for both E-field and B-field sensing capabilities under 3T MRI. These devices are also used to validate the complete electromechanical model for the antenna-coupled coaxial transducer to predict the sensor response to arbitrary incident RF fields. Experiments under MRI show that the sensitivity of fabricated devices is comparable to the previous FBG-based sensor and confirm the feasibility of fully RF-immune device tracking under MRI.","abstract_html":"RF field measurement under MRI presents a significant measurement challenge. Both components of the RF field, the electric field and the magnetic field, are uniquely important for real-time sensing during an MR-sequence: the electric field contributes to deposited RF power in the tissue, leading to increased tissue temperature, while the magnetic field is used for imaging and localization. Conventional RF field sensors use long electrical conductors for signal transmission, which distort images and contribute to local RF power hot-spots, potentially damaging tissue on or in the patient. Current MRI-compatible sensors employ transduction from electrical to optical signals for RF immune signal transmission, which subverts these issues. However, demonstrated sensors either utilize complex, actively pow- ered components, or rely on large, rigid components for passive sensing, all of which may constrain the device geometry, performance, and application. The feasibility of an acousto-optic (AO) RF field sensor structure based on light inten- sity modulation via an antenna-coupled piezoelectric transducer modulating a fiber-Bragg grating (FBG) was demonstrated earlier. This work develops and validates an end-to-end model of the AO sensor to enable design optimization, and a fabrication process based on conformal piezo-composite polymer transducers over optical fibers. The use of coaxial piezoelectric transducers increases the acoustic coupling efficiency and minimize the size of the sensor for seamless integration on interventional MRI catheters as compared to pla- nar and bulky piezo crystals glued to optical fibers. Sensors are designed and fabricated for both E-field and B-field sensing capabilities under 3T MRI. These devices are also used to validate the complete electromechanical model for the antenna-coupled coaxial transducer to predict the sensor response to arbitrary incident RF fields. Experiments under MRI show that the sensitivity of fabricated devices is comparable to the previous FBG-based sensor and confirm the feasibility of fully RF-immune device tracking under MRI.","abstract_has_math":false,"creators":["Bradley, Lee"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Degertekin, F. Levent"],"committee_chairs":[],"committee_members":["Ansari, Azadeh","Chen, Yue","Oshinski, John","Yaras, Yusuf"],"year":2025,"date_issued":"2025-05-13","date_published":"2025-05-13","updated_at":"2026-11-19T05:52:50Z","subjects":["Acousto-Optic","Sensor","Optical","RF","MRI","Piezoelectric","Model"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/78649","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/78649","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F78649","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Degertekin, F. Levent"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Ansari, Azadeh","Chen, Yue","Oshinski, John","Yaras, Yusuf"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","School of Electrical and Computer Engineering"]},{"key":"dc:creator","label":"Author","values":["Bradley, Lee"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-08-15T12:39:58Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-08-15T12:39:58Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-08"]},{"key":"dc:date.issued","label":"Date","values":["2025-05-13"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2025"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2025-08-15T12:39:59Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["9afd92fe-bb98-4c83-b8ac-fc596320991a"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","5b7adef2-447c-4270-b9fc-846bd76f80f2"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Electrical and Computer Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Acousto-Optic","Sensor","Optical","RF","MRI","Piezoelectric","Model"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/78649"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["RF field measurement under MRI presents a significant measurement challenge. Both components of the RF field, the electric field and the magnetic field, are uniquely important for real-time sensing during an MR-sequence: the electric field contributes to deposited RF power in the tissue, leading to increased tissue temperature, while the magnetic field is used for imaging and localization. Conventional RF field sensors use long electrical conductors for signal transmission, which distort images and contribute to local RF power hot-spots, potentially damaging tissue on or in the patient. Current MRI-compatible sensors employ transduction from electrical to optical signals for RF immune signal transmission, which subverts these issues. However, demonstrated sensors either utilize complex, actively pow- ered components, or rely on large, rigid components for passive sensing, all of which may constrain the device geometry, performance, and application. The feasibility of an acousto-optic (AO) RF field sensor structure based on light inten- sity modulation via an antenna-coupled piezoelectric transducer modulating a fiber-Bragg grating (FBG) was demonstrated earlier. This work develops and validates an end-to-end model of the AO sensor to enable design optimization, and a fabrication process based on conformal piezo-composite polymer transducers over optical fibers. The use of coaxial piezoelectric transducers increases the acoustic coupling efficiency and minimize the size of the sensor for seamless integration on interventional MRI catheters as compared to pla- nar and bulky piezo crystals glued to optical fibers. Sensors are designed and fabricated for both E-field and B-field sensing capabilities under 3T MRI. These devices are also used to validate the complete electromechanical model for the antenna-coupled coaxial transducer to predict the sensor response to arbitrary incident RF fields. Experiments under MRI show that the sensitivity of fabricated devices is comparable to the previous FBG-based sensor and confirm the feasibility of fully RF-immune device tracking under MRI."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Miniaturized Acousto-Optic Sensor for RF Field Measurement Under MRI"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Degertekin, F. Levent"],"dc:contributor.committeemember":["Ansari, Azadeh","Chen, Yue","Oshinski, John","Yaras, Yusuf"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["College of Engineering","School of Electrical and Computer Engineering"],"dc:creator":["Bradley, Lee"],"dc:date.accessioned":["2025-08-15T12:39:58Z"],"dc:date.available":["2025-08-15T12:39:58Z"],"dc:date.created":["2025-08"],"dc:date.issued":["2025-05-13"],"dc:date.submitted":["August 2025"],"dc:date.updated":["2025-08-15T12:39:59Z"],"dc:description.abstract":["RF field measurement under MRI presents a significant measurement challenge. Both components of the RF field, the electric field and the magnetic field, are uniquely important for real-time sensing during an MR-sequence: the electric field contributes to deposited RF power in the tissue, leading to increased tissue temperature, while the magnetic field is used for imaging and localization. Conventional RF field sensors use long electrical conductors for signal transmission, which distort images and contribute to local RF power hot-spots, potentially damaging tissue on or in the patient. Current MRI-compatible sensors employ transduction from electrical to optical signals for RF immune signal transmission, which subverts these issues. However, demonstrated sensors either utilize complex, actively pow- ered components, or rely on large, rigid components for passive sensing, all of which may constrain the device geometry, performance, and application. The feasibility of an acousto-optic (AO) RF field sensor structure based on light inten- sity modulation via an antenna-coupled piezoelectric transducer modulating a fiber-Bragg grating (FBG) was demonstrated earlier. This work develops and validates an end-to-end model of the AO sensor to enable design optimization, and a fabrication process based on conformal piezo-composite polymer transducers over optical fibers. The use of coaxial piezoelectric transducers increases the acoustic coupling efficiency and minimize the size of the sensor for seamless integration on interventional MRI catheters as compared to pla- nar and bulky piezo crystals glued to optical fibers. Sensors are designed and fabricated for both E-field and B-field sensing capabilities under 3T MRI. These devices are also used to validate the complete electromechanical model for the antenna-coupled coaxial transducer to predict the sensor response to arbitrary incident RF fields. Experiments under MRI show that the sensitivity of fabricated devices is comparable to the previous FBG-based sensor and confirm the feasibility of fully RF-immune device tracking under MRI."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/78649"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["9afd92fe-bb98-4c83-b8ac-fc596320991a"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","5b7adef2-447c-4270-b9fc-846bd76f80f2"],"dc:subject":["Acousto-Optic","Sensor","Optical","RF","MRI","Piezoelectric","Model"],"dc:title":["Miniaturized Acousto-Optic Sensor for RF Field Measurement Under MRI"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"],"thesis:degree_program":["Electrical and Computer Engineering"]},"updated_at":"2026-11-19T05:52:50Z"}