{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/78681"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/78681","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Modeling and Mitigating Anatomical Uncertainties and Motion in Proton Therapy Via Gaussian Process Prediction and Water Equivalent Thickness Mapping","abstract":"Currently, proton radiotherapy accounts for uncertainties from setup and inter- and intra-fraction anatomical changes using population-based margins. However, by their nature, population-based margins tend to overestimate the actual setup error for most patients, while underestimating it for a minority. To address this, this work uses Gaussian Process (GP) models to predict patient-specific inter-fraction motion. For sites with high anatomical uncertainty such as thoracic cancers, plans are robustly optimized on the on the treatment planning CT (TPCT) and additional images that represent anatomical uncertainty. This optimization technique, termed 4D robust optimization, is inefficient because it optimizes over multiple images. To address this inefficiency, this work will develop water equivalent thickness mapping (WET-MAP), which converts beam path changes from anatomical uncertainty to contour changes on the TPCT. This work applied Gaussian Process Prediction Water Equivalent Thickness Map (GPP-WET-MAP, or GWM), a planning strategy that uses GP regression models to predict patient-specific prostate inter-fraction motion and accounts for the predicted inter-fraction motion with WET mapping, to conventionally fractionated and stereotactic body radiotherapy (SBRT) prostate patients. GWM plans were optimized on just the TPCT, increasing efficiency, and use a smaller setup uncertainty. This work found that, compared to current clinical practice, GWM plans maintain coverage, have improved robustness to inter-fraction motion, and increased organ sparing for both groups of prostate patients, demonstrating a high potential for clinical use.","abstract_html":"Currently, proton radiotherapy accounts for uncertainties from setup and inter- and intra-fraction anatomical changes using population-based margins. However, by their nature, population-based margins tend to overestimate the actual setup error for most patients, while underestimating it for a minority. To address this, this work uses Gaussian Process (GP) models to predict patient-specific inter-fraction motion. For sites with high anatomical uncertainty such as thoracic cancers, plans are robustly optimized on the on the treatment planning CT (TPCT) and additional images that represent anatomical uncertainty. This optimization technique, termed 4D robust optimization, is inefficient because it optimizes over multiple images. To address this inefficiency, this work will develop water equivalent thickness mapping (WET-MAP), which converts beam path changes from anatomical uncertainty to contour changes on the TPCT. This work applied Gaussian Process Prediction Water Equivalent Thickness Map (GPP-WET-MAP, or GWM), a planning strategy that uses GP regression models to predict patient-specific prostate inter-fraction motion and accounts for the predicted inter-fraction motion with WET mapping, to conventionally fractionated and stereotactic body radiotherapy (SBRT) prostate patients. GWM plans were optimized on just the TPCT, increasing efficiency, and use a smaller setup uncertainty. This work found that, compared to current clinical practice, GWM plans maintain coverage, have improved robustness to inter-fraction motion, and increased organ sparing for both groups of prostate patients, demonstrating a high potential for clinical use.","abstract_has_math":false,"creators":["Bohannon, Duncan Henry"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Zhou, Jun","Wang, C.-K. Chris"],"committee_chairs":[],"committee_members":["Biegalski, Steven","Yoon, Paul","Elder, Eric"],"year":2025,"date_issued":"2025-07-11","date_published":"2025-07-11","updated_at":"2026-11-19T04:53:54Z","subjects":["Radiation Therapy","Motion Management","Proton Therapy"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/78681","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/78681","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F78681","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Zhou, Jun","Wang, C.-K. Chris"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Biegalski, Steven","Yoon, Paul","Elder, Eric"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","George W. Woodruff School of Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Bohannon, Duncan Henry"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-08-15T12:41:52Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-08-15T12:41:52Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-08"]},{"key":"dc:date.issued","label":"Date","values":["2025-07-11"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2025"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2025-08-15T12:41:52Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["71d23899-d6d4-4d7f-b9bc-d30323a6f442"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","c01ff908-c25f-439b-bf10-a074ed886bb7"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Medical Physics"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Radiation Therapy","Motion Management","Proton Therapy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/78681"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Currently, proton radiotherapy accounts for uncertainties from setup and inter- and intra-fraction anatomical changes using population-based margins. However, by their nature, population-based margins tend to overestimate the actual setup error for most patients, while underestimating it for a minority. To address this, this work uses Gaussian Process (GP) models to predict patient-specific inter-fraction motion. For sites with high anatomical uncertainty such as thoracic cancers, plans are robustly optimized on the on the treatment planning CT (TPCT) and additional images that represent anatomical uncertainty. This optimization technique, termed 4D robust optimization, is inefficient because it optimizes over multiple images. To address this inefficiency, this work will develop water equivalent thickness mapping (WET-MAP), which converts beam path changes from anatomical uncertainty to contour changes on the TPCT. This work applied Gaussian Process Prediction Water Equivalent Thickness Map (GPP-WET-MAP, or GWM), a planning strategy that uses GP regression models to predict patient-specific prostate inter-fraction motion and accounts for the predicted inter-fraction motion with WET mapping, to conventionally fractionated and stereotactic body radiotherapy (SBRT) prostate patients. GWM plans were optimized on just the TPCT, increasing efficiency, and use a smaller setup uncertainty. This work found that, compared to current clinical practice, GWM plans maintain coverage, have improved robustness to inter-fraction motion, and increased organ sparing for both groups of prostate patients, demonstrating a high potential for clinical use."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Modeling and Mitigating Anatomical Uncertainties and Motion in Proton Therapy Via Gaussian Process Prediction and Water Equivalent Thickness Mapping"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Zhou, Jun","Wang, C.-K. Chris"],"dc:contributor.committeemember":["Biegalski, Steven","Yoon, Paul","Elder, Eric"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["College of Engineering","George W. Woodruff School of Mechanical Engineering"],"dc:creator":["Bohannon, Duncan Henry"],"dc:date.accessioned":["2025-08-15T12:41:52Z"],"dc:date.available":["2025-08-15T12:41:52Z"],"dc:date.created":["2025-08"],"dc:date.issued":["2025-07-11"],"dc:date.submitted":["August 2025"],"dc:date.updated":["2025-08-15T12:41:52Z"],"dc:description.abstract":["Currently, proton radiotherapy accounts for uncertainties from setup and inter- and intra-fraction anatomical changes using population-based margins. However, by their nature, population-based margins tend to overestimate the actual setup error for most patients, while underestimating it for a minority. To address this, this work uses Gaussian Process (GP) models to predict patient-specific inter-fraction motion. For sites with high anatomical uncertainty such as thoracic cancers, plans are robustly optimized on the on the treatment planning CT (TPCT) and additional images that represent anatomical uncertainty. This optimization technique, termed 4D robust optimization, is inefficient because it optimizes over multiple images. To address this inefficiency, this work will develop water equivalent thickness mapping (WET-MAP), which converts beam path changes from anatomical uncertainty to contour changes on the TPCT. This work applied Gaussian Process Prediction Water Equivalent Thickness Map (GPP-WET-MAP, or GWM), a planning strategy that uses GP regression models to predict patient-specific prostate inter-fraction motion and accounts for the predicted inter-fraction motion with WET mapping, to conventionally fractionated and stereotactic body radiotherapy (SBRT) prostate patients. GWM plans were optimized on just the TPCT, increasing efficiency, and use a smaller setup uncertainty. This work found that, compared to current clinical practice, GWM plans maintain coverage, have improved robustness to inter-fraction motion, and increased organ sparing for both groups of prostate patients, demonstrating a high potential for clinical use."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/78681"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["71d23899-d6d4-4d7f-b9bc-d30323a6f442"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","c01ff908-c25f-439b-bf10-a074ed886bb7"],"dc:subject":["Radiation Therapy","Motion Management","Proton Therapy"],"dc:title":["Modeling and Mitigating Anatomical Uncertainties and Motion in Proton Therapy Via Gaussian Process Prediction and Water Equivalent Thickness Mapping"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"],"thesis:degree_program":["Medical Physics"]},"updated_at":"2026-11-19T04:53:54Z"}