{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/80090"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/80090","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Design And Fabrication of MR-Safe Core Needle Breast Biopsy Robot","abstract":"Breast cancer is one of the most prevalent cancers affecting millions of women worldwide. Excisional biopsy, especially MRI-guided percutaneous core-needle biopsy, remains a crucial diagnostic tool for breast cancer. However, MRI-guided biopsies present significant challenges, including the restricted space within the scanner bore and the necessity for multiple imaging steps, all of which extend the procedure and heighten patient discomfort. Unlike ultrasound-guided biopsies that allow for real-time needle positioning, MRI-guided procedures also lack dynamic visual feedback, complicating needle insertion. Advances in medical robotics offer a promising solution to these challenges. Robots can maneuver within the constrained MRI environment, enabling biopsies to be performed with real-time image feedback, thereby enhancing precision and reducing procedure time. This robotic approach has the potential to greatly improve the accuracy and efficiency of MRI-guided breast biopsies, ultimately reducing procedure duration and minimizing patient discomfort.","abstract_html":"Breast cancer is one of the most prevalent cancers affecting millions of women worldwide. Excisional biopsy, especially MRI-guided percutaneous core-needle biopsy, remains a crucial diagnostic tool for breast cancer. However, MRI-guided biopsies present significant challenges, including the restricted space within the scanner bore and the necessity for multiple imaging steps, all of which extend the procedure and heighten patient discomfort. Unlike ultrasound-guided biopsies that allow for real-time needle positioning, MRI-guided procedures also lack dynamic visual feedback, complicating needle insertion. Advances in medical robotics offer a promising solution to these challenges. Robots can maneuver within the constrained MRI environment, enabling biopsies to be performed with real-time image feedback, thereby enhancing precision and reducing procedure time. This robotic approach has the potential to greatly improve the accuracy and efficiency of MRI-guided breast biopsies, ultimately reducing procedure duration and minimizing patient discomfort.","abstract_has_math":false,"creators":["Sentosa, Jason"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Biomedical Engineering (Joint GT/Emory Department)","school":null,"contributors":[],"advisors":["Chen, Yue"],"committee_chairs":[],"committee_members":["Ueda, Jun","Zhao, Ye"],"year":2024,"date_issued":"2024-12-02","date_published":"2024-12-02","updated_at":"2026-11-19T06:12:57Z","subjects":["Breast biopsy","Medical Robotics","MRI-compatible robot"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/80090","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/80090","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F80090","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Chen, Yue"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Ueda, Jun","Zhao, Ye"]},{"key":"dc:contributor.department","label":"Department","values":["Biomedical Engineering (Joint GT/Emory Department)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","Wallace H. Coulter Department of Biomedical Engineering"]},{"key":"dc:creator","label":"Author","values":["Sentosa, Jason"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-01-20T15:03:57Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-01-20T15:03:57Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2024-12"]},{"key":"dc:date.issued","label":"Date","values":["2024-12-02"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2024"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2026-01-20T15:03:59Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["871043fa-0830-42ee-a3c0-14a6e49c7d07"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Biomedical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","da59be3c-3d0a-41da-91b9-ebe2ecc83b66"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["f9608e55-1fc9-4f5c-bc9b-027467e51c31"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis (Masters Degree)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Biomedical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Breast biopsy","Medical Robotics","MRI-compatible robot"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/80090"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Breast cancer is one of the most prevalent cancers affecting millions of women worldwide. Excisional biopsy, especially MRI-guided percutaneous core-needle biopsy, remains a crucial diagnostic tool for breast cancer. However, MRI-guided biopsies present significant challenges, including the restricted space within the scanner bore and the necessity for multiple imaging steps, all of which extend the procedure and heighten patient discomfort. Unlike ultrasound-guided biopsies that allow for real-time needle positioning, MRI-guided procedures also lack dynamic visual feedback, complicating needle insertion. Advances in medical robotics offer a promising solution to these challenges. Robots can maneuver within the constrained MRI environment, enabling biopsies to be performed with real-time image feedback, thereby enhancing precision and reducing procedure time. This robotic approach has the potential to greatly improve the accuracy and efficiency of MRI-guided breast biopsies, ultimately reducing procedure duration and minimizing patient discomfort."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Design And Fabrication of MR-Safe Core Needle Breast Biopsy Robot"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Chen, Yue"],"dc:contributor.committeemember":["Ueda, Jun","Zhao, Ye"],"dc:contributor.department":["Biomedical Engineering (Joint GT/Emory Department)"],"dc:contributor.other":["College of Engineering","Wallace H. Coulter Department of Biomedical Engineering"],"dc:creator":["Sentosa, Jason"],"dc:date.accessioned":["2026-01-20T15:03:57Z"],"dc:date.available":["2026-01-20T15:03:57Z"],"dc:date.created":["2024-12"],"dc:date.issued":["2024-12-02"],"dc:date.submitted":["December 2024"],"dc:date.updated":["2026-01-20T15:03:59Z"],"dc:description.abstract":["Breast cancer is one of the most prevalent cancers affecting millions of women worldwide. Excisional biopsy, especially MRI-guided percutaneous core-needle biopsy, remains a crucial diagnostic tool for breast cancer. However, MRI-guided biopsies present significant challenges, including the restricted space within the scanner bore and the necessity for multiple imaging steps, all of which extend the procedure and heighten patient discomfort. Unlike ultrasound-guided biopsies that allow for real-time needle positioning, MRI-guided procedures also lack dynamic visual feedback, complicating needle insertion. Advances in medical robotics offer a promising solution to these challenges. Robots can maneuver within the constrained MRI environment, enabling biopsies to be performed with real-time image feedback, thereby enhancing precision and reducing procedure time. This robotic approach has the potential to greatly improve the accuracy and efficiency of MRI-guided breast biopsies, ultimately reducing procedure duration and minimizing patient discomfort."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/80090"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["871043fa-0830-42ee-a3c0-14a6e49c7d07"],"dc:relation.ispartofseries":["Master of Science in Biomedical Engineering"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","da59be3c-3d0a-41da-91b9-ebe2ecc83b66"],"dc:relation.seriesentity":["f9608e55-1fc9-4f5c-bc9b-027467e51c31"],"dc:subject":["Breast biopsy","Medical Robotics","MRI-compatible robot"],"dc:title":["Design And Fabrication of MR-Safe Core Needle Breast Biopsy Robot"],"dc:type":["Text","Thesis (Masters Degree)"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"],"thesis:degree_program":["Biomedical Engineering"]},"updated_at":"2026-11-19T06:12:57Z"}