{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/80279"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/80279","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Low Noise Double-Beam Absorption Spectroscopy","abstract":"This thesis focuses on adapting an analog noise-cancellation circuit for double-beam laser absorption spectroscopy to improve accuracy in ammonia concentration measurements. By suppressing common-mode laser intensity noise, the circuit enhances absorption sensitivity without requiring complex modulation techniques. In this approach, a tunable diode laser beam is split into two paths: a signal beam that passes through an absorption cell and a reference beam that bypasses any absorbing medium. The two beams are independently detected and their corresponding photocurrents are fed into an electronic circuit designed to suppress the common-mode noise on laser intensity, thereby enhancing the diagnostic technique’s accuracy. This architecture remains cost-effective and has the potential to achieve shot-noise-limited performance. A circuit originally designed by Philip Hobbs was adapted, simulated in Analog Devices LTspice, prototyped on a breadboard and ultimately implemented on a printed circuit board. Performance was evaluated using a water-vapor absorption setup and compared against both a standard DAS sensor and a commercial double-beam noise-cancellation module from MKS–Newport. Results show a clear improvement in NEA over standard DAS, with performance approaching that of the commercial system. Finally, extended-range InGaAs photodetectors were integrated to enable ammonia detection and the circuit was used to record room-temperature ammonia absorption line shapes and time-resolved absorption measurements of ammonia oxidation under post-reflected shock conditions in shock-tube experiments.","abstract_html":"This thesis focuses on adapting an analog noise-cancellation circuit for double-beam laser absorption spectroscopy to improve accuracy in ammonia concentration measurements. By suppressing common-mode laser intensity noise, the circuit enhances absorption sensitivity without requiring complex modulation techniques. In this approach, a tunable diode laser beam is split into two paths: a signal beam that passes through an absorption cell and a reference beam that bypasses any absorbing medium. The two beams are independently detected and their corresponding photocurrents are fed into an electronic circuit designed to suppress the common-mode noise on laser intensity, thereby enhancing the diagnostic technique’s accuracy. This architecture remains cost-effective and has the potential to achieve shot-noise-limited performance. A circuit originally designed by Philip Hobbs was adapted, simulated in Analog Devices LTspice, prototyped on a breadboard and ultimately implemented on a printed circuit board. Performance was evaluated using a water-vapor absorption setup and compared against both a standard DAS sensor and a commercial double-beam noise-cancellation module from MKS–Newport. Results show a clear improvement in NEA over standard DAS, with performance approaching that of the commercial system. Finally, extended-range InGaAs photodetectors were integrated to enable ammonia detection and the circuit was used to record room-temperature ammonia absorption line shapes and time-resolved absorption measurements of ammonia oxidation under post-reflected shock conditions in shock-tube experiments.","abstract_has_math":false,"creators":["Preve, Federico"],"institution":"Georgia Institute of Technology","degree_name":"Aerospace Engineering, MS","degree_level":null,"degree_discipline":null,"degree_department":"Aerospace Engineering","school":null,"contributors":[],"advisors":["Steinberg, Adam M."],"committee_chairs":[],"committee_members":["Sun, Wenting","Wehe, Shawn"],"year":2025,"date_issued":"2025-12","date_published":"2025-12","updated_at":"2026-11-19T04:26:06Z","subjects":[],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/80279","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/80279","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F80279","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Steinberg, Adam M."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Sun, Wenting","Wehe, Shawn"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","Daniel Guggenheim School of Aerospace Engineering"]},{"key":"dc:creator","label":"Author","values":["Preve, Federico"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-01-26T14:57:22Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-01-26T14:57:22Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-12"]},{"key":"dc:date.issued","label":"Date","values":["2025-12"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2025"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2026-01-26T14:57:22Z"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["7935aa46-f13f-4b9a-b224-0ae809a73226"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Aerospace Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","a348b767-ea7e-4789-af1f-1f1d5925fb65"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["09844fbb-b7d9-45e2-95de-849e434a6abc"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis (Masters Degree)"]},{"key":"thesis:degree_college","label":"Thesis Degree College","values":["College of Engineering"]},{"key":"thesis:degree_department","label":"Department","values":["Aerospace Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Aerospace Engineering, MS"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Georgia Institute of Technology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/80279"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis focuses on adapting an analog noise-cancellation circuit for double-beam laser absorption spectroscopy to improve accuracy in ammonia concentration measurements. By suppressing common-mode laser intensity noise, the circuit enhances absorption sensitivity without requiring complex modulation techniques. In this approach, a tunable diode laser beam is split into two paths: a signal beam that passes through an absorption cell and a reference beam that bypasses any absorbing medium. The two beams are independently detected and their corresponding photocurrents are fed into an electronic circuit designed to suppress the common-mode noise on laser intensity, thereby enhancing the diagnostic technique’s accuracy. This architecture remains cost-effective and has the potential to achieve shot-noise-limited performance. A circuit originally designed by Philip Hobbs was adapted, simulated in Analog Devices LTspice, prototyped on a breadboard and ultimately implemented on a printed circuit board. Performance was evaluated using a water-vapor absorption setup and compared against both a standard DAS sensor and a commercial double-beam noise-cancellation module from MKS–Newport. Results show a clear improvement in NEA over standard DAS, with performance approaching that of the commercial system. Finally, extended-range InGaAs photodetectors were integrated to enable ammonia detection and the circuit was used to record room-temperature ammonia absorption line shapes and time-resolved absorption measurements of ammonia oxidation under post-reflected shock conditions in shock-tube experiments."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Low Noise Double-Beam Absorption Spectroscopy"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Steinberg, Adam M."],"dc:contributor.committeemember":["Sun, Wenting","Wehe, Shawn"],"dc:contributor.other":["College of Engineering","Daniel Guggenheim School of Aerospace Engineering"],"dc:creator":["Preve, Federico"],"dc:date.accessioned":["2026-01-26T14:57:22Z"],"dc:date.available":["2026-01-26T14:57:22Z"],"dc:date.created":["2025-12"],"dc:date.issued":["2025-12"],"dc:date.submitted":["December 2025"],"dc:date.updated":["2026-01-26T14:57:22Z"],"dc:description.abstract":["This thesis focuses on adapting an analog noise-cancellation circuit for double-beam laser absorption spectroscopy to improve accuracy in ammonia concentration measurements. By suppressing common-mode laser intensity noise, the circuit enhances absorption sensitivity without requiring complex modulation techniques. In this approach, a tunable diode laser beam is split into two paths: a signal beam that passes through an absorption cell and a reference beam that bypasses any absorbing medium. The two beams are independently detected and their corresponding photocurrents are fed into an electronic circuit designed to suppress the common-mode noise on laser intensity, thereby enhancing the diagnostic technique’s accuracy. This architecture remains cost-effective and has the potential to achieve shot-noise-limited performance. A circuit originally designed by Philip Hobbs was adapted, simulated in Analog Devices LTspice, prototyped on a breadboard and ultimately implemented on a printed circuit board. Performance was evaluated using a water-vapor absorption setup and compared against both a standard DAS sensor and a commercial double-beam noise-cancellation module from MKS–Newport. Results show a clear improvement in NEA over standard DAS, with performance approaching that of the commercial system. Finally, extended-range InGaAs photodetectors were integrated to enable ammonia detection and the circuit was used to record room-temperature ammonia absorption line shapes and time-resolved absorption measurements of ammonia oxidation under post-reflected shock conditions in shock-tube experiments."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/80279"],"dc:language.iso":["English"],"dc:relation.advisorentity":["7935aa46-f13f-4b9a-b224-0ae809a73226"],"dc:relation.ispartofseries":["Master of Science in Aerospace Engineering"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","a348b767-ea7e-4789-af1f-1f1d5925fb65"],"dc:relation.seriesentity":["09844fbb-b7d9-45e2-95de-849e434a6abc"],"dc:title":["Low Noise Double-Beam Absorption Spectroscopy"],"dc:type":["Text","Thesis (Masters Degree)"],"dspace:entity.type":["Publication"],"thesis:degree_college":["College of Engineering"],"thesis:degree_department":["Aerospace Engineering"],"thesis:degree_name":["Aerospace Engineering, MS"],"thesis:institution_name":["Georgia Institute of Technology"]},"updated_at":"2026-11-19T04:26:06Z"}