{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/80297"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/80297","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Light Yield and F-O-M Irradiation Degradation of Polysiloxane, Polyvinyltoluen, EJ200, and EJ276D Organic Scintillators Via a 6MV, 40kgy Absorbed Dose","abstract":"Sixteen samples of organic scintillators fabricated from polysiloxane and polyvinyltoluene bulk solvents were taken to quantify their radiation hardness and irradiation degradation mechanisms. These samples received an absorbed dose of 40 kGy of 6MV irradiation via a Varian Clinical Linear Accelerator and their light yield and figure-of-merit were analyzed in increments of 10 kGy. It was found that the polysiloxane bulk solvent has a slower rate of light yield degradation, but a faster rate of figure-of-merit degradation when compared to the PVT matrix. At 10kGy, control samples EJ200 and EJ276 were among the highest rates of percent light yield and F-O-M degradation when compared to all samples. Additionally, secondary dopant, Bis-MSB, had the highest rates of light yield degradation across both bulk solvents at 40kGy, suggesting a radio-sensitivity.","abstract_html":"Sixteen samples of organic scintillators fabricated from polysiloxane and polyvinyltoluene bulk solvents were taken to quantify their radiation hardness and irradiation degradation mechanisms. These samples received an absorbed dose of 40 kGy of 6MV irradiation via a Varian Clinical Linear Accelerator and their light yield and figure-of-merit were analyzed in increments of 10 kGy. It was found that the polysiloxane bulk solvent has a slower rate of light yield degradation, but a faster rate of figure-of-merit degradation when compared to the PVT matrix. At 10kGy, control samples EJ200 and EJ276 were among the highest rates of percent light yield and F-O-M degradation when compared to all samples. Additionally, secondary dopant, Bis-MSB, had the highest rates of light yield degradation across both bulk solvents at 40kGy, suggesting a radio-sensitivity.","abstract_has_math":false,"creators":["Lassair, Erick"],"institution":"Georgia Institute of Technology","degree_name":"Medical Physics, MS","degree_level":null,"degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Erickson, Anna S."],"committee_chairs":[],"committee_members":["Biegalski, Steven","Wang, C","Elder, Eric"],"year":2025,"date_issued":"2025-12","date_published":"2025-12","updated_at":"2026-11-19T05:04:28Z","subjects":[],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/80297","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/80297","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F80297","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Erickson, Anna S."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Biegalski, Steven","Wang, C","Elder, Eric"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","George W. Woodruff School of Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Lassair, Erick"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-01-26T14:58:34Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-01-26T14:58:34Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-12"]},{"key":"dc:date.issued","label":"Date","values":["2025-12"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2025"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2026-01-26T14:58:34Z"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["df2e2349-4cf3-4d53-89e5-adc9b56c9ac6"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Medical Physics"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","c01ff908-c25f-439b-bf10-a074ed886bb7"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["3173665c-cfb8-400b-bcf7-8fbfc614e0fb"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis (Masters Degree)"]},{"key":"thesis:degree_college","label":"Thesis Degree College","values":["College of Engineering"]},{"key":"thesis:degree_department","label":"Department","values":["Mechanical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Medical Physics, MS"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Georgia Institute of Technology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/80297"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Sixteen samples of organic scintillators fabricated from polysiloxane and polyvinyltoluene bulk solvents were taken to quantify their radiation hardness and irradiation degradation mechanisms. These samples received an absorbed dose of 40 kGy of 6MV irradiation via a Varian Clinical Linear Accelerator and their light yield and figure-of-merit were analyzed in increments of 10 kGy. It was found that the polysiloxane bulk solvent has a slower rate of light yield degradation, but a faster rate of figure-of-merit degradation when compared to the PVT matrix. At 10kGy, control samples EJ200 and EJ276 were among the highest rates of percent light yield and F-O-M degradation when compared to all samples. Additionally, secondary dopant, Bis-MSB, had the highest rates of light yield degradation across both bulk solvents at 40kGy, suggesting a radio-sensitivity."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Light Yield and F-O-M Irradiation Degradation of Polysiloxane, Polyvinyltoluen, EJ200, and EJ276D Organic Scintillators Via a 6MV, 40kgy Absorbed Dose"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Erickson, Anna S."],"dc:contributor.committeemember":["Biegalski, Steven","Wang, C","Elder, Eric"],"dc:contributor.other":["College of Engineering","George W. Woodruff School of Mechanical Engineering"],"dc:creator":["Lassair, Erick"],"dc:date.accessioned":["2026-01-26T14:58:34Z"],"dc:date.available":["2026-01-26T14:58:34Z"],"dc:date.created":["2025-12"],"dc:date.issued":["2025-12"],"dc:date.submitted":["December 2025"],"dc:date.updated":["2026-01-26T14:58:34Z"],"dc:description.abstract":["Sixteen samples of organic scintillators fabricated from polysiloxane and polyvinyltoluene bulk solvents were taken to quantify their radiation hardness and irradiation degradation mechanisms. These samples received an absorbed dose of 40 kGy of 6MV irradiation via a Varian Clinical Linear Accelerator and their light yield and figure-of-merit were analyzed in increments of 10 kGy. It was found that the polysiloxane bulk solvent has a slower rate of light yield degradation, but a faster rate of figure-of-merit degradation when compared to the PVT matrix. At 10kGy, control samples EJ200 and EJ276 were among the highest rates of percent light yield and F-O-M degradation when compared to all samples. Additionally, secondary dopant, Bis-MSB, had the highest rates of light yield degradation across both bulk solvents at 40kGy, suggesting a radio-sensitivity."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/80297"],"dc:language.iso":["English"],"dc:relation.advisorentity":["df2e2349-4cf3-4d53-89e5-adc9b56c9ac6"],"dc:relation.ispartofseries":["Master of Science in Medical Physics"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","c01ff908-c25f-439b-bf10-a074ed886bb7"],"dc:relation.seriesentity":["3173665c-cfb8-400b-bcf7-8fbfc614e0fb"],"dc:title":["Light Yield and F-O-M Irradiation Degradation of Polysiloxane, Polyvinyltoluen, EJ200, and EJ276D Organic Scintillators Via a 6MV, 40kgy Absorbed Dose"],"dc:type":["Text","Thesis (Masters Degree)"],"dspace:entity.type":["Publication"],"thesis:degree_college":["College of Engineering"],"thesis:degree_department":["Mechanical Engineering"],"thesis:degree_name":["Medical Physics, MS"],"thesis:institution_name":["Georgia Institute of Technology"]},"updated_at":"2026-11-19T05:04:28Z"}