{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/81510"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/81510","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Optical and Electronic Detection of Molecular and Cellular Biomarkers Using Enzymatic Metallization for Multiplexed and Point-of-Care Diagnostics","abstract":"Measures of humoral immune response (i.e. antibodies) and cellular immune response (i.e. cytokines) serve as biomarkers for diseases. Current sensitive and specific methods of quantifying their concentrations in sample are lab-based methods that are time consuming and required trained personnel to perform, leading to delays in diagnosis and treatment. Though point-of-care (POC) tests like lateral flow assays (LFAs) exist and are widely used, they are limited in sensitivity and typically measure antibodies. We have earlier developed an inexpensive, multiplexed, enzymatic metallization-based assay on a glass slide for the detection of antibodies. Thus, the goal of this work was to address the need for POC cytokine detection, and to further develop our antibody detection platform. We expanded on our former enzymatic metallization work by entering the cytokine space, where an almost ~1000-fold increase in sensitivity was necessary. First, we identify cytokines of interest, then develop our enzymatic metallization slide-based cytokine platform for detection down to ~11 pg/mL, both optically and through impedance readouts. Further, we develop an assay for impedance-based detection of cytokine directly from cells. Lastly, we redesign our antibody detection assay into a sample-to-format answer, with that goal of making it user-friendly and storable. Ultimately, this work explores the capabilities of enzymatic metallization-based assays to detect various molecule types and validates these platforms for diagnostic use.","abstract_html":"Measures of humoral immune response (i.e. antibodies) and cellular immune response (i.e. cytokines) serve as biomarkers for diseases. Current sensitive and specific methods of quantifying their concentrations in sample are lab-based methods that are time consuming and required trained personnel to perform, leading to delays in diagnosis and treatment. Though point-of-care (POC) tests like lateral flow assays (LFAs) exist and are widely used, they are limited in sensitivity and typically measure antibodies. We have earlier developed an inexpensive, multiplexed, enzymatic metallization-based assay on a glass slide for the detection of antibodies. Thus, the goal of this work was to address the need for POC cytokine detection, and to further develop our antibody detection platform. We expanded on our former enzymatic metallization work by entering the cytokine space, where an almost ~1000-fold increase in sensitivity was necessary. First, we identify cytokines of interest, then develop our enzymatic metallization slide-based cytokine platform for detection down to ~11 pg/mL, both optically and through impedance readouts. Further, we develop an assay for impedance-based detection of cytokine directly from cells. Lastly, we redesign our antibody detection assay into a sample-to-format answer, with that goal of making it user-friendly and storable. Ultimately, this work explores the capabilities of enzymatic metallization-based assays to detect various molecule types and validates these platforms for diagnostic use.","abstract_has_math":false,"creators":["Hashim, Asma"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Biomedical Engineering (Joint GT/Emory Department)","school":null,"contributors":[],"advisors":["Sarkar, Aniruddh"],"committee_chairs":[],"committee_members":["Myers, David","Day, Cheryl"],"year":2025,"date_issued":"2025-04-30","date_published":"2025-04-30","updated_at":"2026-11-19T05:55:35Z","subjects":["point-of-care","cytokines","diagnostic","antibody","immunoassay"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/81510","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/81510","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F81510","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Sarkar, Aniruddh"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Myers, David","Day, Cheryl"]},{"key":"dc:contributor.department","label":"Department","values":["Biomedical Engineering (Joint GT/Emory Department)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","Wallace H. Coulter Department of Biomedical Engineering"]},{"key":"dc:creator","label":"Author","values":["Hashim, Asma"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-05-21T20:39:33Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-05-21T20:39:33Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-05"]},{"key":"dc:date.issued","label":"Date","values":["2025-04-30"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2025"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2026-05-21T20:39:38Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["ace47750-bfad-4c09-8198-11ce4920c8ed"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Biomedical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","da59be3c-3d0a-41da-91b9-ebe2ecc83b66"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["f9608e55-1fc9-4f5c-bc9b-027467e51c31"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis (Masters Degree)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Biomedical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["point-of-care","cytokines","diagnostic","antibody","immunoassay"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/81510"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Measures of humoral immune response (i.e. antibodies) and cellular immune response (i.e. cytokines) serve as biomarkers for diseases. Current sensitive and specific methods of quantifying their concentrations in sample are lab-based methods that are time consuming and required trained personnel to perform, leading to delays in diagnosis and treatment. Though point-of-care (POC) tests like lateral flow assays (LFAs) exist and are widely used, they are limited in sensitivity and typically measure antibodies. We have earlier developed an inexpensive, multiplexed, enzymatic metallization-based assay on a glass slide for the detection of antibodies. Thus, the goal of this work was to address the need for POC cytokine detection, and to further develop our antibody detection platform. We expanded on our former enzymatic metallization work by entering the cytokine space, where an almost ~1000-fold increase in sensitivity was necessary. First, we identify cytokines of interest, then develop our enzymatic metallization slide-based cytokine platform for detection down to ~11 pg/mL, both optically and through impedance readouts. Further, we develop an assay for impedance-based detection of cytokine directly from cells. Lastly, we redesign our antibody detection assay into a sample-to-format answer, with that goal of making it user-friendly and storable. Ultimately, this work explores the capabilities of enzymatic metallization-based assays to detect various molecule types and validates these platforms for diagnostic use."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Optical and Electronic Detection of Molecular and Cellular Biomarkers Using Enzymatic Metallization for Multiplexed and Point-of-Care Diagnostics"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Sarkar, Aniruddh"],"dc:contributor.committeemember":["Myers, David","Day, Cheryl"],"dc:contributor.department":["Biomedical Engineering (Joint GT/Emory Department)"],"dc:contributor.other":["College of Engineering","Wallace H. Coulter Department of Biomedical Engineering"],"dc:creator":["Hashim, Asma"],"dc:date.accessioned":["2026-05-21T20:39:33Z"],"dc:date.available":["2026-05-21T20:39:33Z"],"dc:date.created":["2025-05"],"dc:date.issued":["2025-04-30"],"dc:date.submitted":["May 2025"],"dc:date.updated":["2026-05-21T20:39:38Z"],"dc:description.abstract":["Measures of humoral immune response (i.e. antibodies) and cellular immune response (i.e. cytokines) serve as biomarkers for diseases. Current sensitive and specific methods of quantifying their concentrations in sample are lab-based methods that are time consuming and required trained personnel to perform, leading to delays in diagnosis and treatment. Though point-of-care (POC) tests like lateral flow assays (LFAs) exist and are widely used, they are limited in sensitivity and typically measure antibodies. We have earlier developed an inexpensive, multiplexed, enzymatic metallization-based assay on a glass slide for the detection of antibodies. Thus, the goal of this work was to address the need for POC cytokine detection, and to further develop our antibody detection platform. We expanded on our former enzymatic metallization work by entering the cytokine space, where an almost ~1000-fold increase in sensitivity was necessary. First, we identify cytokines of interest, then develop our enzymatic metallization slide-based cytokine platform for detection down to ~11 pg/mL, both optically and through impedance readouts. Further, we develop an assay for impedance-based detection of cytokine directly from cells. Lastly, we redesign our antibody detection assay into a sample-to-format answer, with that goal of making it user-friendly and storable. Ultimately, this work explores the capabilities of enzymatic metallization-based assays to detect various molecule types and validates these platforms for diagnostic use."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/81510"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["ace47750-bfad-4c09-8198-11ce4920c8ed"],"dc:relation.ispartofseries":["Master of Science in Biomedical Engineering"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","da59be3c-3d0a-41da-91b9-ebe2ecc83b66"],"dc:relation.seriesentity":["f9608e55-1fc9-4f5c-bc9b-027467e51c31"],"dc:subject":["point-of-care","cytokines","diagnostic","antibody","immunoassay"],"dc:title":["Optical and Electronic Detection of Molecular and Cellular Biomarkers Using Enzymatic Metallization for Multiplexed and Point-of-Care Diagnostics"],"dc:type":["Text","Thesis (Masters Degree)"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"],"thesis:degree_program":["Biomedical Engineering"]},"updated_at":"2026-11-19T05:55:35Z"}