{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/81560"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/81560","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Automated device for real-time frequency-specific visual stimulation of the brain","abstract":"This project presents the design, implementation, and validation of the Auto Flicker system, a fully automated device for delivering frequency-specific visual stimulation to rodent models. Built with a National Instruments USB-6001 NIDAQ interface, MATLAB-controlled signal generation, and real-time photodiode monitoring, the system supports chronic stimulation protocols at 20Hz and 40Hz. The design allows for simultaneous dual-frequency output into separate animal housing compartments, minimizing manual intervention and enhancing reproducibility. Power spectral analyses confirm consistent delivery of target frequencies over extended sessions, while automated email alerts ensure early detection of frequency deviations. By integrating the stimulation system directly into home cages, the design also eliminates stress induced by daily animal transport. Immunohistochemical analysis following long-term use demonstrates that the device supports tissue integrity and enables downstream cellular studies, including microglial morphology reconstruction. This system represents a scalable and reliable tool for neuromodulation research, particularly in Alzheimer’s disease models where frequency-specific stimulation may influence neuroimmune responses.","abstract_html":"This project presents the design, implementation, and validation of the Auto Flicker system, a fully automated device for delivering frequency-specific visual stimulation to rodent models. Built with a National Instruments USB-6001 NIDAQ interface, MATLAB-controlled signal generation, and real-time photodiode monitoring, the system supports chronic stimulation protocols at 20Hz and 40Hz. The design allows for simultaneous dual-frequency output into separate animal housing compartments, minimizing manual intervention and enhancing reproducibility. Power spectral analyses confirm consistent delivery of target frequencies over extended sessions, while automated email alerts ensure early detection of frequency deviations. By integrating the stimulation system directly into home cages, the design also eliminates stress induced by daily animal transport. Immunohistochemical analysis following long-term use demonstrates that the device supports tissue integrity and enables downstream cellular studies, including microglial morphology reconstruction. This system represents a scalable and reliable tool for neuromodulation research, particularly in Alzheimer’s disease models where frequency-specific stimulation may influence neuroimmune responses.","abstract_has_math":false,"creators":["Zepeda, Hector"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Biomedical Engineering (Joint GT/Emory Department)","school":null,"contributors":[],"advisors":["Singer, Annabelle C."],"committee_chairs":[],"committee_members":["Wood, Levi","Fong, Ming-Fai"],"year":2025,"date_issued":"2025-05-02","date_published":"2025-05-02","updated_at":"2026-11-19T05:51:10Z","subjects":["Neurostimulation","Flicker stimulation","20Hz stimulation","40Hz stimulation","Alzheimer’s disease","Microglia","Home cage stimulation","Photodiode monitoring","Power spectral analysis","Neuroimmune modulation","MATLAB control system","NIDAQ","Rodent model","Chronic stimulation"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/81560","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/81560","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F81560","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Singer, Annabelle C."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Wood, Levi","Fong, Ming-Fai"]},{"key":"dc:contributor.department","label":"Department","values":["Biomedical Engineering (Joint GT/Emory Department)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","Wallace H. Coulter Department of Biomedical Engineering"]},{"key":"dc:creator","label":"Author","values":["Zepeda, Hector"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-05-21T20:43:30Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-05-21T20:43:30Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-05"]},{"key":"dc:date.issued","label":"Date","values":["2025-05-02"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2025"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2026-05-21T20:43:34Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["d60cd47d-9428-4eef-a574-933f0ef8d262"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Biomedical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","da59be3c-3d0a-41da-91b9-ebe2ecc83b66"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["f9608e55-1fc9-4f5c-bc9b-027467e51c31"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis (Masters Degree)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Biomedical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Neurostimulation","Flicker stimulation","20Hz stimulation","40Hz stimulation","Alzheimer’s disease","Microglia","Home cage stimulation","Photodiode monitoring","Power spectral analysis","Neuroimmune modulation","MATLAB control system","NIDAQ","Rodent model","Chronic stimulation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/81560"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This project presents the design, implementation, and validation of the Auto Flicker system, a fully automated device for delivering frequency-specific visual stimulation to rodent models. Built with a National Instruments USB-6001 NIDAQ interface, MATLAB-controlled signal generation, and real-time photodiode monitoring, the system supports chronic stimulation protocols at 20Hz and 40Hz. The design allows for simultaneous dual-frequency output into separate animal housing compartments, minimizing manual intervention and enhancing reproducibility. Power spectral analyses confirm consistent delivery of target frequencies over extended sessions, while automated email alerts ensure early detection of frequency deviations. By integrating the stimulation system directly into home cages, the design also eliminates stress induced by daily animal transport. Immunohistochemical analysis following long-term use demonstrates that the device supports tissue integrity and enables downstream cellular studies, including microglial morphology reconstruction. This system represents a scalable and reliable tool for neuromodulation research, particularly in Alzheimer’s disease models where frequency-specific stimulation may influence neuroimmune responses."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Automated device for real-time frequency-specific visual stimulation of the brain"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Singer, Annabelle C."],"dc:contributor.committeemember":["Wood, Levi","Fong, Ming-Fai"],"dc:contributor.department":["Biomedical Engineering (Joint GT/Emory Department)"],"dc:contributor.other":["College of Engineering","Wallace H. Coulter Department of Biomedical Engineering"],"dc:creator":["Zepeda, Hector"],"dc:date.accessioned":["2026-05-21T20:43:30Z"],"dc:date.available":["2026-05-21T20:43:30Z"],"dc:date.created":["2025-05"],"dc:date.issued":["2025-05-02"],"dc:date.submitted":["May 2025"],"dc:date.updated":["2026-05-21T20:43:34Z"],"dc:description.abstract":["This project presents the design, implementation, and validation of the Auto Flicker system, a fully automated device for delivering frequency-specific visual stimulation to rodent models. Built with a National Instruments USB-6001 NIDAQ interface, MATLAB-controlled signal generation, and real-time photodiode monitoring, the system supports chronic stimulation protocols at 20Hz and 40Hz. The design allows for simultaneous dual-frequency output into separate animal housing compartments, minimizing manual intervention and enhancing reproducibility. Power spectral analyses confirm consistent delivery of target frequencies over extended sessions, while automated email alerts ensure early detection of frequency deviations. By integrating the stimulation system directly into home cages, the design also eliminates stress induced by daily animal transport. Immunohistochemical analysis following long-term use demonstrates that the device supports tissue integrity and enables downstream cellular studies, including microglial morphology reconstruction. This system represents a scalable and reliable tool for neuromodulation research, particularly in Alzheimer’s disease models where frequency-specific stimulation may influence neuroimmune responses."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/81560"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["d60cd47d-9428-4eef-a574-933f0ef8d262"],"dc:relation.ispartofseries":["Master of Science in Biomedical Engineering"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","da59be3c-3d0a-41da-91b9-ebe2ecc83b66"],"dc:relation.seriesentity":["f9608e55-1fc9-4f5c-bc9b-027467e51c31"],"dc:subject":["Neurostimulation","Flicker stimulation","20Hz stimulation","40Hz stimulation","Alzheimer’s disease","Microglia","Home cage stimulation","Photodiode monitoring","Power spectral analysis","Neuroimmune modulation","MATLAB control system","NIDAQ","Rodent model","Chronic stimulation"],"dc:title":["Automated device for real-time frequency-specific visual stimulation of the brain"],"dc:type":["Text","Thesis (Masters Degree)"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"],"thesis:degree_program":["Biomedical Engineering"]},"updated_at":"2026-11-19T05:51:10Z"}