{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/81561"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/81561","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Forward-viewing intravascular ultrasound-derived wall shear stress for PCI optimization: phantom and CFD studies","abstract":"Percutaneous coronary intervention (PCI) is the current standard of care to relieve ischemia, with approximately 3 million PCIs performed annually. However, 25-33% of patients will experience recurrent angina or major adverse cardiac events (MACE) by the two-year follow-up, and 10% of patients will experience restenosis at the 5-year follow-up. Guiding PCI with optical coherence tomography (OCT), intravascular ultrasound (IVUS), or fractional flow reserve (FFR) has been shown to reduce MACE and restenosis for post-PCI patients. Wall shear stress (WSS) is a hemodynamic variable that has demonstrated incremental value in predicting plaque initiation, progression, and vulnerability. Therefore, the ability to image WSS during PCI could improve stent placement and reduce rates of MACE and restenosis after PCI. In order to determine the ability of forward-viewing intravascular ultrasound (FV-IVUS) to assess stent placement by imaging WSS, a high frequency commercial linear array was placed in a forward-viewing position and used to acquire images in 9 different scenarios in vessel-mimicking phantoms. Each phantom had one of three geometries: straight, stenotic, or patient-specific, and one of three variations in stent positioning: no stent, malapposed stent, or well-apposed stent. A syringe pump was used to inject a microbubble solution with a 0.025% concentration at 20 ml/min through each phantom. The fluid flow velocity was estimated in both axial and lateral directions. WSS was estimated from ultrasound imaging data with a pseudo-spectral method and compared with CFD for validation. US-derived WSS data was split into three regions: proximal, middle, and distal. WSS estimations were significantly lower at the malapposed sites (proximal region) compared to the middle and distal thirds. WSS spatial variation was significantly higher in the malapposed cases compared to the well-apposed cases. The velocity values had a mean correlation coefficient of 81.91%. The mean absolute percent error (MAPE) between US-derived and CFD-derived velocities was 15.03%. The peak velocity estimation between US-derived and CFD-derived velocities showed 90.09% agreement. The WSS trends agreed qualitatively. To our knowledge, this is the first investigation of US imaging-derived WSS in stented coronary artery geometries. Finally, using our recently-developed FV-IVUS 2D array, we also present the first WSS maps based on real-time 3D US with a 2D array. Real-time WSS estimation during the PCI procedure could potentially improve patient outcomes by improving optimization of stent placement or identifying patients at high risk of restenosis by using this data in long-term coronary artery modeling (i.e. a digital twin system).","abstract_html":"Percutaneous coronary intervention (PCI) is the current standard of care to relieve ischemia, with approximately 3 million PCIs performed annually. However, 25-33% of patients will experience recurrent angina or major adverse cardiac events (MACE) by the two-year follow-up, and 10% of patients will experience restenosis at the 5-year follow-up. Guiding PCI with optical coherence tomography (OCT), intravascular ultrasound (IVUS), or fractional flow reserve (FFR) has been shown to reduce MACE and restenosis for post-PCI patients. Wall shear stress (WSS) is a hemodynamic variable that has demonstrated incremental value in predicting plaque initiation, progression, and vulnerability. Therefore, the ability to image WSS during PCI could improve stent placement and reduce rates of MACE and restenosis after PCI. In order to determine the ability of forward-viewing intravascular ultrasound (FV-IVUS) to assess stent placement by imaging WSS, a high frequency commercial linear array was placed in a forward-viewing position and used to acquire images in 9 different scenarios in vessel-mimicking phantoms. Each phantom had one of three geometries: straight, stenotic, or patient-specific, and one of three variations in stent positioning: no stent, malapposed stent, or well-apposed stent. A syringe pump was used to inject a microbubble solution with a 0.025% concentration at 20 ml/min through each phantom. The fluid flow velocity was estimated in both axial and lateral directions. WSS was estimated from ultrasound imaging data with a pseudo-spectral method and compared with CFD for validation. US-derived WSS data was split into three regions: proximal, middle, and distal. WSS estimations were significantly lower at the malapposed sites (proximal region) compared to the middle and distal thirds. WSS spatial variation was significantly higher in the malapposed cases compared to the well-apposed cases. The velocity values had a mean correlation coefficient of 81.91%. The mean absolute percent error (MAPE) between US-derived and CFD-derived velocities was 15.03%. The peak velocity estimation between US-derived and CFD-derived velocities showed 90.09% agreement. The WSS trends agreed qualitatively. To our knowledge, this is the first investigation of US imaging-derived WSS in stented coronary artery geometries. Finally, using our recently-developed FV-IVUS 2D array, we also present the first WSS maps based on real-time 3D US with a 2D array. Real-time WSS estimation during the PCI procedure could potentially improve patient outcomes by improving optimization of stent placement or identifying patients at high risk of restenosis by using this data in long-term coronary artery modeling (i.e. a digital twin system).","abstract_has_math":false,"creators":["Singh, Travis Christian"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Biomedical Engineering (Joint GT/Emory Department)","school":null,"contributors":[],"advisors":["Lindsey, Brooks"],"committee_chairs":[],"committee_members":["Veneziani, Alessandro","Oshinski, John"],"year":2025,"date_issued":"2025-04-30","date_published":"2025-04-30","updated_at":"2026-11-19T04:26:06Z","subjects":["Wall shear stress","stent malapposition, blood flow velocity","coronary artery","forward viewing","percutaneous coronary intervention","ultrasound"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/81561","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/81561","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F81561","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Lindsey, Brooks"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Veneziani, Alessandro","Oshinski, John"]},{"key":"dc:contributor.department","label":"Department","values":["Biomedical Engineering (Joint GT/Emory Department)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","Wallace H. Coulter Department of Biomedical Engineering"]},{"key":"dc:creator","label":"Author","values":["Singh, Travis Christian"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-05-21T20:43:35Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-05-21T20:43:35Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-05"]},{"key":"dc:date.issued","label":"Date","values":["2025-04-30"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2025"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2026-05-21T20:43:35Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["fed87d1e-1ba5-4c44-8fc1-e6cc17b6aa87"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Biomedical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","da59be3c-3d0a-41da-91b9-ebe2ecc83b66"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["f9608e55-1fc9-4f5c-bc9b-027467e51c31"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis (Masters Degree)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Biomedical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Wall shear stress","stent malapposition, blood flow velocity","coronary artery","forward viewing","percutaneous coronary intervention","ultrasound"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/81561"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Percutaneous coronary intervention (PCI) is the current standard of care to relieve ischemia, with approximately 3 million PCIs performed annually. However, 25-33% of patients will experience recurrent angina or major adverse cardiac events (MACE) by the two-year follow-up, and 10% of patients will experience restenosis at the 5-year follow-up. Guiding PCI with optical coherence tomography (OCT), intravascular ultrasound (IVUS), or fractional flow reserve (FFR) has been shown to reduce MACE and restenosis for post-PCI patients. Wall shear stress (WSS) is a hemodynamic variable that has demonstrated incremental value in predicting plaque initiation, progression, and vulnerability. Therefore, the ability to image WSS during PCI could improve stent placement and reduce rates of MACE and restenosis after PCI. In order to determine the ability of forward-viewing intravascular ultrasound (FV-IVUS) to assess stent placement by imaging WSS, a high frequency commercial linear array was placed in a forward-viewing position and used to acquire images in 9 different scenarios in vessel-mimicking phantoms. Each phantom had one of three geometries: straight, stenotic, or patient-specific, and one of three variations in stent positioning: no stent, malapposed stent, or well-apposed stent. A syringe pump was used to inject a microbubble solution with a 0.025% concentration at 20 ml/min through each phantom. The fluid flow velocity was estimated in both axial and lateral directions. WSS was estimated from ultrasound imaging data with a pseudo-spectral method and compared with CFD for validation. US-derived WSS data was split into three regions: proximal, middle, and distal. WSS estimations were significantly lower at the malapposed sites (proximal region) compared to the middle and distal thirds. WSS spatial variation was significantly higher in the malapposed cases compared to the well-apposed cases. The velocity values had a mean correlation coefficient of 81.91%. The mean absolute percent error (MAPE) between US-derived and CFD-derived velocities was 15.03%. The peak velocity estimation between US-derived and CFD-derived velocities showed 90.09% agreement. The WSS trends agreed qualitatively. To our knowledge, this is the first investigation of US imaging-derived WSS in stented coronary artery geometries. Finally, using our recently-developed FV-IVUS 2D array, we also present the first WSS maps based on real-time 3D US with a 2D array. Real-time WSS estimation during the PCI procedure could potentially improve patient outcomes by improving optimization of stent placement or identifying patients at high risk of restenosis by using this data in long-term coronary artery modeling (i.e. a digital twin system)."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Forward-viewing intravascular ultrasound-derived wall shear stress for PCI optimization: phantom and CFD studies"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Lindsey, Brooks"],"dc:contributor.committeemember":["Veneziani, Alessandro","Oshinski, John"],"dc:contributor.department":["Biomedical Engineering (Joint GT/Emory Department)"],"dc:contributor.other":["College of Engineering","Wallace H. Coulter Department of Biomedical Engineering"],"dc:creator":["Singh, Travis Christian"],"dc:date.accessioned":["2026-05-21T20:43:35Z"],"dc:date.available":["2026-05-21T20:43:35Z"],"dc:date.created":["2025-05"],"dc:date.issued":["2025-04-30"],"dc:date.submitted":["May 2025"],"dc:date.updated":["2026-05-21T20:43:35Z"],"dc:description.abstract":["Percutaneous coronary intervention (PCI) is the current standard of care to relieve ischemia, with approximately 3 million PCIs performed annually. However, 25-33% of patients will experience recurrent angina or major adverse cardiac events (MACE) by the two-year follow-up, and 10% of patients will experience restenosis at the 5-year follow-up. Guiding PCI with optical coherence tomography (OCT), intravascular ultrasound (IVUS), or fractional flow reserve (FFR) has been shown to reduce MACE and restenosis for post-PCI patients. Wall shear stress (WSS) is a hemodynamic variable that has demonstrated incremental value in predicting plaque initiation, progression, and vulnerability. Therefore, the ability to image WSS during PCI could improve stent placement and reduce rates of MACE and restenosis after PCI. In order to determine the ability of forward-viewing intravascular ultrasound (FV-IVUS) to assess stent placement by imaging WSS, a high frequency commercial linear array was placed in a forward-viewing position and used to acquire images in 9 different scenarios in vessel-mimicking phantoms. Each phantom had one of three geometries: straight, stenotic, or patient-specific, and one of three variations in stent positioning: no stent, malapposed stent, or well-apposed stent. A syringe pump was used to inject a microbubble solution with a 0.025% concentration at 20 ml/min through each phantom. The fluid flow velocity was estimated in both axial and lateral directions. WSS was estimated from ultrasound imaging data with a pseudo-spectral method and compared with CFD for validation. US-derived WSS data was split into three regions: proximal, middle, and distal. WSS estimations were significantly lower at the malapposed sites (proximal region) compared to the middle and distal thirds. WSS spatial variation was significantly higher in the malapposed cases compared to the well-apposed cases. The velocity values had a mean correlation coefficient of 81.91%. The mean absolute percent error (MAPE) between US-derived and CFD-derived velocities was 15.03%. The peak velocity estimation between US-derived and CFD-derived velocities showed 90.09% agreement. The WSS trends agreed qualitatively. To our knowledge, this is the first investigation of US imaging-derived WSS in stented coronary artery geometries. Finally, using our recently-developed FV-IVUS 2D array, we also present the first WSS maps based on real-time 3D US with a 2D array. Real-time WSS estimation during the PCI procedure could potentially improve patient outcomes by improving optimization of stent placement or identifying patients at high risk of restenosis by using this data in long-term coronary artery modeling (i.e. a digital twin system)."],"dc:description.degree":["M.S."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/81561"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["fed87d1e-1ba5-4c44-8fc1-e6cc17b6aa87"],"dc:relation.ispartofseries":["Master of Science in Biomedical Engineering"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","da59be3c-3d0a-41da-91b9-ebe2ecc83b66"],"dc:relation.seriesentity":["f9608e55-1fc9-4f5c-bc9b-027467e51c31"],"dc:subject":["Wall shear stress","stent malapposition, blood flow velocity","coronary artery","forward viewing","percutaneous coronary intervention","ultrasound"],"dc:title":["Forward-viewing intravascular ultrasound-derived wall shear stress for PCI optimization: phantom and CFD studies"],"dc:type":["Text","Thesis (Masters Degree)"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Masters"],"thesis:degree_program":["Biomedical Engineering"]},"updated_at":"2026-11-19T04:26:06Z"}