{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/82034"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/82034","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Large-Field High-Temporal-Resolution Microscopic Imaging: Deconvolution and Dynamic Range Improvement","abstract":"The discovery of cells has driven life sciences forward, yet large-field high-temporal-resolution fluorescence microscopy remains hampered by massive data volumes, short exposures and low bit depths that cause photon starvation, motion blur and limited dynamic range. We introduce two complementary computational solutions. First, PEARL deconvolution uses third-order gradient extrapolation to predict and apply optimal update steps, significantly reduce the iteration counts and reconstruction times in both simulated and real 3D datasets—from organelles to organoids—without loss of spatial resolution. Second, Self-Supervised Fluorescence Microscopy High Dynamic Range Reconstruction (Self-FM-HDR) fuses multiple low dynamic range frames with artifact-mitigation strategies to recover a 16-bit-equivalent dynamic range, preserving fine structure in both dim and bright regions under photon-limited conditions. Together, PEARL’s speed and Self-FM-HDR’s expanded intensity range relieve the dual bottlenecks of slow reconstruction rate and low image quality of large-field high-temporal-resolution fluorescence microscopy, possibly laying a robust foundation for next-generation, fast volumetric monitoring of dynamic biological processes.","abstract_html":"The discovery of cells has driven life sciences forward, yet large-field high-temporal-resolution fluorescence microscopy remains hampered by massive data volumes, short exposures and low bit depths that cause photon starvation, motion blur and limited dynamic range. We introduce two complementary computational solutions. First, PEARL deconvolution uses third-order gradient extrapolation to predict and apply optimal update steps, significantly reduce the iteration counts and reconstruction times in both simulated and real 3D datasets—from organelles to organoids—without loss of spatial resolution. Second, Self-Supervised Fluorescence Microscopy High Dynamic Range Reconstruction (Self-FM-HDR) fuses multiple low dynamic range frames with artifact-mitigation strategies to recover a 16-bit-equivalent dynamic range, preserving fine structure in both dim and bright regions under photon-limited conditions. Together, PEARL’s speed and Self-FM-HDR’s expanded intensity range relieve the dual bottlenecks of slow reconstruction rate and low image quality of large-field high-temporal-resolution fluorescence microscopy, possibly laying a robust foundation for next-generation, fast volumetric monitoring of dynamic biological processes.","abstract_has_math":false,"creators":["Wu, Shunan"],"institution":"Georgia Institute of Technology","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":"Biomedical Engineering (Joint GT/Emory Department)","school":null,"contributors":[],"advisors":["Wei, Xunbin","Jia, Shu"],"committee_chairs":[],"committee_members":["Xi, Peng","Li, Changhui","Luo, Jiajia"],"year":2025,"date_issued":"2025-07-01","date_published":"2025-07-01","updated_at":"2026-11-19T06:04:01Z","subjects":["Fluorescence microscopy","Deconvolution","High dynamic range imaging","Light-field microscopy","Computational imaging"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/82034","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/82034","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F82034","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Wei, Xunbin","Jia, Shu"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Xi, Peng","Li, Changhui","Luo, Jiajia"]},{"key":"dc:contributor.department","label":"Department","values":["Biomedical Engineering (Joint GT/Emory Department)"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","Wallace H. Coulter Department of Biomedical Engineering"]},{"key":"dc:creator","label":"Author","values":["Wu, Shunan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-09-15T21:01:09Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-09-15T21:01:09Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-08"]},{"key":"dc:date.issued","label":"Date","values":["2025-07-01"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2025"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2026-09-15T21:01:11Z"]},{"key":"dc:publisher","label":"Institution","values":["Georgia Institute of Technology"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["ff019f26-736b-47e9-bbb0-2e7037d1c17d"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Biomedical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","da59be3c-3d0a-41da-91b9-ebe2ecc83b66"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["d85f9f1b-b2b5-4bca-81af-4515c5281e54"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Biomedical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Fluorescence microscopy","Deconvolution","High dynamic range imaging","Light-field microscopy","Computational imaging"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/82034"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The discovery of cells has driven life sciences forward, yet large-field high-temporal-resolution fluorescence microscopy remains hampered by massive data volumes, short exposures and low bit depths that cause photon starvation, motion blur and limited dynamic range. We introduce two complementary computational solutions. First, PEARL deconvolution uses third-order gradient extrapolation to predict and apply optimal update steps, significantly reduce the iteration counts and reconstruction times in both simulated and real 3D datasets—from organelles to organoids—without loss of spatial resolution. Second, Self-Supervised Fluorescence Microscopy High Dynamic Range Reconstruction (Self-FM-HDR) fuses multiple low dynamic range frames with artifact-mitigation strategies to recover a 16-bit-equivalent dynamic range, preserving fine structure in both dim and bright regions under photon-limited conditions. Together, PEARL’s speed and Self-FM-HDR’s expanded intensity range relieve the dual bottlenecks of slow reconstruction rate and low image quality of large-field high-temporal-resolution fluorescence microscopy, possibly laying a robust foundation for next-generation, fast volumetric monitoring of dynamic biological processes."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Large-Field High-Temporal-Resolution Microscopic Imaging: Deconvolution and Dynamic Range Improvement"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Wei, Xunbin","Jia, Shu"],"dc:contributor.committeemember":["Xi, Peng","Li, Changhui","Luo, Jiajia"],"dc:contributor.department":["Biomedical Engineering (Joint GT/Emory Department)"],"dc:contributor.other":["College of Engineering","Wallace H. Coulter Department of Biomedical Engineering"],"dc:creator":["Wu, Shunan"],"dc:date.accessioned":["2026-09-15T21:01:09Z"],"dc:date.available":["2026-09-15T21:01:09Z"],"dc:date.created":["2025-08"],"dc:date.issued":["2025-07-01"],"dc:date.submitted":["August 2025"],"dc:date.updated":["2026-09-15T21:01:11Z"],"dc:description.abstract":["The discovery of cells has driven life sciences forward, yet large-field high-temporal-resolution fluorescence microscopy remains hampered by massive data volumes, short exposures and low bit depths that cause photon starvation, motion blur and limited dynamic range. We introduce two complementary computational solutions. First, PEARL deconvolution uses third-order gradient extrapolation to predict and apply optimal update steps, significantly reduce the iteration counts and reconstruction times in both simulated and real 3D datasets—from organelles to organoids—without loss of spatial resolution. Second, Self-Supervised Fluorescence Microscopy High Dynamic Range Reconstruction (Self-FM-HDR) fuses multiple low dynamic range frames with artifact-mitigation strategies to recover a 16-bit-equivalent dynamic range, preserving fine structure in both dim and bright regions under photon-limited conditions. Together, PEARL’s speed and Self-FM-HDR’s expanded intensity range relieve the dual bottlenecks of slow reconstruction rate and low image quality of large-field high-temporal-resolution fluorescence microscopy, possibly laying a robust foundation for next-generation, fast volumetric monitoring of dynamic biological processes."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/82034"],"dc:language.iso":["en_US"],"dc:publisher":["Georgia Institute of Technology"],"dc:relation.advisorentity":["ff019f26-736b-47e9-bbb0-2e7037d1c17d"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Biomedical Engineering"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","da59be3c-3d0a-41da-91b9-ebe2ecc83b66"],"dc:relation.seriesentity":["d85f9f1b-b2b5-4bca-81af-4515c5281e54"],"dc:subject":["Fluorescence microscopy","Deconvolution","High dynamic range imaging","Light-field microscopy","Computational imaging"],"dc:title":["Large-Field High-Temporal-Resolution Microscopic Imaging: Deconvolution and Dynamic Range Improvement"],"dc:type":["Text","Dissertation"],"dspace:entity.type":["Publication"],"thesis:degree_level":["Doctoral"],"thesis:degree_program":["Biomedical Engineering"]},"updated_at":"2026-11-19T06:04:01Z"}