{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/82111"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/82111","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"A Novel 3D Dose Detector Using A Plastic Scintillator and MV Image Reconstruction","abstract":"External beam radiation therapy (EBRT) using photons employs a C-Arm linear accelerator (LINAC) to deliver complex dose distributions to a defined target while simultaneously sparing surrounding organs at risk (OARs) and adjacent tissue. Dose calculation algorithms used in treatment planning for these customized distributions generally have high accuracy, but complex scenarios involving very sharp dose gradients or targets located off axis require verification. Currently available dose measurement devices are capable of simple point -dose or coarse planar characterization of radiation doses but are unable to provide a full three-dimensional (3D) representation of these complex dose distributions. This project proposes the development of a novel radiation detector capable of measuring and quantifying 3D dose distributions. This detector system utilizes a cylindrical plastic scintillator that emits light in response to radiation exposure, which is captured by a camera. This optical signal is combined with measurements from a planar detector, the electronic portal imaging device (EPID). Signals measured by the camera and the EPID are fused to reconstruct dose in 2D and 3D with submillimeter resolution. This system successfully validated dosimetric parameters for monthly quality assurance of a LINAC using 2D imaging. It also reconstructed 3D dose distributions with submillimeter resolution and demonstrated improved agreement with calculations in the treatment planning system compared to existing 3D detectors. The detector is capable of validating very sharp dose gradients from complex modulated fields, including targets located off axis.","abstract_html":"External beam radiation therapy (EBRT) using photons employs a C-Arm linear accelerator (LINAC) to deliver complex dose distributions to a defined target while simultaneously sparing surrounding organs at risk (OARs) and adjacent tissue. Dose calculation algorithms used in treatment planning for these customized distributions generally have high accuracy, but complex scenarios involving very sharp dose gradients or targets located off axis require verification. Currently available dose measurement devices are capable of simple point -dose or coarse planar characterization of radiation doses but are unable to provide a full three-dimensional (3D) representation of these complex dose distributions. This project proposes the development of a novel radiation detector capable of measuring and quantifying 3D dose distributions. This detector system utilizes a cylindrical plastic scintillator that emits light in response to radiation exposure, which is captured by a camera. This optical signal is combined with measurements from a planar detector, the electronic portal imaging device (EPID). Signals measured by the camera and the EPID are fused to reconstruct dose in 2D and 3D with submillimeter resolution. This system successfully validated dosimetric parameters for monthly quality assurance of a LINAC using 2D imaging. It also reconstructed 3D dose distributions with submillimeter resolution and demonstrated improved agreement with calculations in the treatment planning system compared to existing 3D detectors. The detector is capable of validating very sharp dose gradients from complex modulated fields, including targets located off axis.","abstract_has_math":false,"creators":["Penoncello, Gregory Paul"],"institution":"Georgia Institute of Technology","degree_name":"Nuclear Engineering, PhD","degree_level":null,"degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Wang, C.-K. Chris"],"committee_chairs":[],"committee_members":["Biegalski, Steven","Erickson, Anna","Jones, Bernard","Altunbas, Cem"],"year":2026,"date_issued":"2026-08","date_published":"2026-08","updated_at":"2026-11-19T04:26:16Z","subjects":[],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000-0002-1224-7102"],"render_values":[{"text":"0000-0002-1224-7102","href":"https://orcid.org/0000-0002-1224-7102","code":true}]}]},"links":{"outbound_url":"https://hdl.handle.net/1853/82111","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/82111","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F82111","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Wang, C.-K. Chris"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Biegalski, Steven","Erickson, Anna","Jones, Bernard","Altunbas, Cem"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","George W. Woodruff School of Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Penoncello, Gregory Paul"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000-0002-1224-7102"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-09-23T18:46:55Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-09-23T18:46:55Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2026-08"]},{"key":"dc:date.issued","label":"Date","values":["2026-08"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2026"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2026-09-23T18:46:55Z"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["71d23899-d6d4-4d7f-b9bc-d30323a6f442"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Nuclear Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","c01ff908-c25f-439b-bf10-a074ed886bb7"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["b2bc2e12-2afc-4a4d-bf4c-0ce7832bcefe"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation (PhD)"]},{"key":"thesis:degree_college","label":"Thesis Degree College","values":["College of Engineering"]},{"key":"thesis:degree_department","label":"Department","values":["Mechanical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Nuclear Engineering, PhD"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Georgia Institute of Technology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/82111"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["External beam radiation therapy (EBRT) using photons employs a C-Arm linear accelerator (LINAC) to deliver complex dose distributions to a defined target while simultaneously sparing surrounding organs at risk (OARs) and adjacent tissue. Dose calculation algorithms used in treatment planning for these customized distributions generally have high accuracy, but complex scenarios involving very sharp dose gradients or targets located off axis require verification. Currently available dose measurement devices are capable of simple point -dose or coarse planar characterization of radiation doses but are unable to provide a full three-dimensional (3D) representation of these complex dose distributions. This project proposes the development of a novel radiation detector capable of measuring and quantifying 3D dose distributions. This detector system utilizes a cylindrical plastic scintillator that emits light in response to radiation exposure, which is captured by a camera. This optical signal is combined with measurements from a planar detector, the electronic portal imaging device (EPID). Signals measured by the camera and the EPID are fused to reconstruct dose in 2D and 3D with submillimeter resolution. This system successfully validated dosimetric parameters for monthly quality assurance of a LINAC using 2D imaging. It also reconstructed 3D dose distributions with submillimeter resolution and demonstrated improved agreement with calculations in the treatment planning system compared to existing 3D detectors. The detector is capable of validating very sharp dose gradients from complex modulated fields, including targets located off axis."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A Novel 3D Dose Detector Using A Plastic Scintillator and MV Image Reconstruction"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Wang, C.-K. Chris"],"dc:contributor.committeemember":["Biegalski, Steven","Erickson, Anna","Jones, Bernard","Altunbas, Cem"],"dc:contributor.other":["College of Engineering","George W. Woodruff School of Mechanical Engineering"],"dc:creator":["Penoncello, Gregory Paul"],"dc:date.accessioned":["2026-09-23T18:46:55Z"],"dc:date.available":["2026-09-23T18:46:55Z"],"dc:date.created":["2026-08"],"dc:date.issued":["2026-08"],"dc:date.submitted":["August 2026"],"dc:date.updated":["2026-09-23T18:46:55Z"],"dc:description.abstract":["External beam radiation therapy (EBRT) using photons employs a C-Arm linear accelerator (LINAC) to deliver complex dose distributions to a defined target while simultaneously sparing surrounding organs at risk (OARs) and adjacent tissue. Dose calculation algorithms used in treatment planning for these customized distributions generally have high accuracy, but complex scenarios involving very sharp dose gradients or targets located off axis require verification. Currently available dose measurement devices are capable of simple point -dose or coarse planar characterization of radiation doses but are unable to provide a full three-dimensional (3D) representation of these complex dose distributions. This project proposes the development of a novel radiation detector capable of measuring and quantifying 3D dose distributions. This detector system utilizes a cylindrical plastic scintillator that emits light in response to radiation exposure, which is captured by a camera. This optical signal is combined with measurements from a planar detector, the electronic portal imaging device (EPID). Signals measured by the camera and the EPID are fused to reconstruct dose in 2D and 3D with submillimeter resolution. This system successfully validated dosimetric parameters for monthly quality assurance of a LINAC using 2D imaging. It also reconstructed 3D dose distributions with submillimeter resolution and demonstrated improved agreement with calculations in the treatment planning system compared to existing 3D detectors. The detector is capable of validating very sharp dose gradients from complex modulated fields, including targets located off axis."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/82111"],"dc:language.iso":["English"],"dc:relation.advisorentity":["71d23899-d6d4-4d7f-b9bc-d30323a6f442"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Nuclear Engineering"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","c01ff908-c25f-439b-bf10-a074ed886bb7"],"dc:relation.seriesentity":["b2bc2e12-2afc-4a4d-bf4c-0ce7832bcefe"],"dc:title":["A Novel 3D Dose Detector Using A Plastic Scintillator and MV Image Reconstruction"],"dc:type":["Text","Dissertation (PhD)"],"dspace:entity.type":["Publication"],"person:identifier.orcid":["0000-0002-1224-7102"],"thesis:degree_college":["College of Engineering"],"thesis:degree_department":["Mechanical Engineering"],"thesis:degree_name":["Nuclear Engineering, PhD"],"thesis:institution_name":["Georgia Institute of Technology"]},"updated_at":"2026-11-19T04:26:16Z"}