{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/82161"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/82161","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Integrated Circuits Design for Emerging Medical Ultrasound Imaging System-on-a-chip","abstract":"In this thesis, two directions would be explored to mitigate realistic constraints. One direction focuses on miniaturization and integration of the front-end ASIC. Targeted for intravascular ultrasound (IVUS), two integrated SoCs for guidewire ultrasound imaging systems have been designed and fabricated. The presented approaches are equally applicable in other miniature probes, such as intracardiac echography (ICE) catheters. The transmit micro-beamforming technique has also been implemented on-chip to steer the acoustic wave and further increase the signal-to-noise ratio (SNR) without losing the frame rate. The other direction focuses on high-performance ADC and communication. A space-time compressed sensing framework for full-channel radio frequency (RF) data acquisition is also proposed for multi-model, high-resolution, high-framerate ultrasound imaging in low power integrated SoCs.","abstract_html":"In this thesis, two directions would be explored to mitigate realistic constraints. One direction focuses on miniaturization and integration of the front-end ASIC. Targeted for intravascular ultrasound (IVUS), two integrated SoCs for guidewire ultrasound imaging systems have been designed and fabricated. The presented approaches are equally applicable in other miniature probes, such as intracardiac echography (ICE) catheters. The transmit micro-beamforming technique has also been implemented on-chip to steer the acoustic wave and further increase the signal-to-noise ratio (SNR) without losing the frame rate. The other direction focuses on high-performance ADC and communication. A space-time compressed sensing framework for full-channel radio frequency (RF) data acquisition is also proposed for multi-model, high-resolution, high-framerate ultrasound imaging in low power integrated SoCs.","abstract_has_math":false,"creators":["Zhang, Xitie"],"institution":"Georgia Institute of Technology","degree_name":"Electrical and Computer Engineering, PhD","degree_level":null,"degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Li, Shaolan"],"committee_chairs":[],"committee_members":["Degertekin, F","Inan, Omer","Sathe, Visvesh","Gu, Jane","Tekes, Coskun"],"year":2026,"date_issued":"2026-08","date_published":"2026-08","updated_at":"2026-11-19T04:26:16Z","subjects":[],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000-0002-3054-6587"],"render_values":[{"text":"0000-0002-3054-6587","href":"https://orcid.org/0000-0002-3054-6587","code":true}]}]},"links":{"outbound_url":"https://hdl.handle.net/1853/82161","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/82161","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F82161","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Li, Shaolan"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Degertekin, F","Inan, Omer","Sathe, Visvesh","Gu, Jane","Tekes, Coskun"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","School of Electrical and Computer Engineering"]},{"key":"dc:creator","label":"Author","values":["Zhang, Xitie"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000-0002-3054-6587"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-09-23T18:59:07Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-09-23T18:59:07Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2026-08"]},{"key":"dc:date.issued","label":"Date","values":["2026-08"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2026"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2026-09-23T18:59:08Z"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["f26e146e-5dc3-49da-8f67-c8c272a4228d"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","5b7adef2-447c-4270-b9fc-846bd76f80f2"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation (PhD)"]},{"key":"thesis:degree_college","label":"Thesis Degree College","values":["College of Engineering"]},{"key":"thesis:degree_department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Electrical and Computer Engineering, PhD"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Georgia Institute of Technology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/82161"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In this thesis, two directions would be explored to mitigate realistic constraints. One direction focuses on miniaturization and integration of the front-end ASIC. Targeted for intravascular ultrasound (IVUS), two integrated SoCs for guidewire ultrasound imaging systems have been designed and fabricated. The presented approaches are equally applicable in other miniature probes, such as intracardiac echography (ICE) catheters. The transmit micro-beamforming technique has also been implemented on-chip to steer the acoustic wave and further increase the signal-to-noise ratio (SNR) without losing the frame rate. The other direction focuses on high-performance ADC and communication. A space-time compressed sensing framework for full-channel radio frequency (RF) data acquisition is also proposed for multi-model, high-resolution, high-framerate ultrasound imaging in low power integrated SoCs."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Integrated Circuits Design for Emerging Medical Ultrasound Imaging System-on-a-chip"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Li, Shaolan"],"dc:contributor.committeemember":["Degertekin, F","Inan, Omer","Sathe, Visvesh","Gu, Jane","Tekes, Coskun"],"dc:contributor.other":["College of Engineering","School of Electrical and Computer Engineering"],"dc:creator":["Zhang, Xitie"],"dc:date.accessioned":["2026-09-23T18:59:07Z"],"dc:date.available":["2026-09-23T18:59:07Z"],"dc:date.created":["2026-08"],"dc:date.issued":["2026-08"],"dc:date.submitted":["August 2026"],"dc:date.updated":["2026-09-23T18:59:08Z"],"dc:description.abstract":["In this thesis, two directions would be explored to mitigate realistic constraints. One direction focuses on miniaturization and integration of the front-end ASIC. Targeted for intravascular ultrasound (IVUS), two integrated SoCs for guidewire ultrasound imaging systems have been designed and fabricated. The presented approaches are equally applicable in other miniature probes, such as intracardiac echography (ICE) catheters. The transmit micro-beamforming technique has also been implemented on-chip to steer the acoustic wave and further increase the signal-to-noise ratio (SNR) without losing the frame rate. The other direction focuses on high-performance ADC and communication. A space-time compressed sensing framework for full-channel radio frequency (RF) data acquisition is also proposed for multi-model, high-resolution, high-framerate ultrasound imaging in low power integrated SoCs."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/82161"],"dc:language.iso":["English"],"dc:relation.advisorentity":["f26e146e-5dc3-49da-8f67-c8c272a4228d"],"dc:relation.ispartofseries":["Doctor of Philosophy with a Major in Electrical and Computer Engineering"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","5b7adef2-447c-4270-b9fc-846bd76f80f2"],"dc:relation.seriesentity":["3890cd56-8ecf-424b-8074-8f5ebd8dbe15"],"dc:title":["Integrated Circuits Design for Emerging Medical Ultrasound Imaging System-on-a-chip"],"dc:type":["Text","Dissertation (PhD)"],"dspace:entity.type":["Publication"],"person:identifier.orcid":["0000-0002-3054-6587"],"thesis:degree_college":["College of Engineering"],"thesis:degree_department":["Electrical and Computer Engineering"],"thesis:degree_name":["Electrical and Computer Engineering, PhD"],"thesis:institution_name":["Georgia Institute of Technology"]},"updated_at":"2026-11-19T04:26:16Z"}