{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/82200"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/82200","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Lightweight Transformers for Echocardiographic Ejection Fraction Estimation: Frame Encoding Strategies and Anatomical Auxiliary Supervision","abstract":"Automated estimation of left ventricular ejection fraction from echocardiographic video could reduce the time and variability associated with manual assessment. This thesis investigates how frame-encoding strategies and anatomical auxiliary supervision affect a lightweight six-layer transformer trained on 10,030 videos from EchoNet-Dynamic. Four frame encoders were evaluated: a linear projection, an ImageNet-pretrained ResNet-50, an adjacent-frame contrastive encoder, and a same-video contrastive encoder. A separately trained U-Net achieved a validation Dice score of 0.936 on expert-annotated end-diastolic and end-systolic frames and generated ventricular cavity masks, normalized cavity areas, and frame-to-frame area changes as auxiliary training targets. Among the evaluated encoders, the linear projection provided the strongest and most consistent regression performance. It also supported the strongest alignment with the generated anatomical targets, with auxiliary mask Dice scores of 0.88 to 0.91 and median area-trajectory correlations of 0.93 to 0.95 across more than 1,100 eligible test videos. However, stronger anatomical alignment did not produce a consistent or practically meaningful improvement in ejection fraction accuracy. These findings show that frame-encoder choice was the primary performance driver in the evaluated framework and that improved anatomical representation does not necessarily translate into improved clinical regression.","abstract_html":"Automated estimation of left ventricular ejection fraction from echocardiographic video could reduce the time and variability associated with manual assessment. This thesis investigates how frame-encoding strategies and anatomical auxiliary supervision affect a lightweight six-layer transformer trained on 10,030 videos from EchoNet-Dynamic. Four frame encoders were evaluated: a linear projection, an ImageNet-pretrained ResNet-50, an adjacent-frame contrastive encoder, and a same-video contrastive encoder. A separately trained U-Net achieved a validation Dice score of 0.936 on expert-annotated end-diastolic and end-systolic frames and generated ventricular cavity masks, normalized cavity areas, and frame-to-frame area changes as auxiliary training targets. Among the evaluated encoders, the linear projection provided the strongest and most consistent regression performance. It also supported the strongest alignment with the generated anatomical targets, with auxiliary mask Dice scores of 0.88 to 0.91 and median area-trajectory correlations of 0.93 to 0.95 across more than 1,100 eligible test videos. However, stronger anatomical alignment did not produce a consistent or practically meaningful improvement in ejection fraction accuracy. These findings show that frame-encoder choice was the primary performance driver in the evaluated framework and that improved anatomical representation does not necessarily translate into improved clinical regression.","abstract_has_math":false,"creators":["Wang, Shaunna"],"institution":"Georgia Institute of Technology","degree_name":"Biomedical Engineering, MS","degree_level":null,"degree_discipline":null,"degree_department":"Biomedical Engineering (Joint GT/Emory Department)","school":null,"contributors":[],"advisors":["Wang, May Dongmei"],"committee_chairs":[],"committee_members":["Coskun, Ahmet","Dasi, Lakshmi"],"year":2026,"date_issued":"2026-08","date_published":"2026-08","updated_at":"2026-11-19T04:54:06Z","subjects":[],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0009-0006-4736-7012"],"render_values":[{"text":"0009-0006-4736-7012","href":"https://orcid.org/0009-0006-4736-7012","code":true}]}]},"links":{"outbound_url":"https://hdl.handle.net/1853/82200","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/82200","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F82200","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Wang, May Dongmei"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Coskun, Ahmet","Dasi, Lakshmi"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","Wallace H. Coulter Department of Biomedical Engineering"]},{"key":"dc:creator","label":"Author","values":["Wang, Shaunna"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0009-0006-4736-7012"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-09-23T19:03:40Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-09-23T19:03:40Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2026-08"]},{"key":"dc:date.issued","label":"Date","values":["2026-08"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2026"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2026-09-23T19:03:41Z"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["e8cb038f-ed3c-41d4-9159-0e51e2e069f1"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Biomedical Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","da59be3c-3d0a-41da-91b9-ebe2ecc83b66"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["f9608e55-1fc9-4f5c-bc9b-027467e51c31"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis (Masters Degree)"]},{"key":"thesis:degree_college","label":"Thesis Degree College","values":["College of Engineering"]},{"key":"thesis:degree_department","label":"Department","values":["Biomedical Engineering (Joint GT/Emory Department)"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Biomedical Engineering, MS"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Georgia Institute of Technology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/82200"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Automated estimation of left ventricular ejection fraction from echocardiographic video could reduce the time and variability associated with manual assessment. This thesis investigates how frame-encoding strategies and anatomical auxiliary supervision affect a lightweight six-layer transformer trained on 10,030 videos from EchoNet-Dynamic. Four frame encoders were evaluated: a linear projection, an ImageNet-pretrained ResNet-50, an adjacent-frame contrastive encoder, and a same-video contrastive encoder. A separately trained U-Net achieved a validation Dice score of 0.936 on expert-annotated end-diastolic and end-systolic frames and generated ventricular cavity masks, normalized cavity areas, and frame-to-frame area changes as auxiliary training targets. Among the evaluated encoders, the linear projection provided the strongest and most consistent regression performance. It also supported the strongest alignment with the generated anatomical targets, with auxiliary mask Dice scores of 0.88 to 0.91 and median area-trajectory correlations of 0.93 to 0.95 across more than 1,100 eligible test videos. However, stronger anatomical alignment did not produce a consistent or practically meaningful improvement in ejection fraction accuracy. These findings show that frame-encoder choice was the primary performance driver in the evaluated framework and that improved anatomical representation does not necessarily translate into improved clinical regression."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Lightweight Transformers for Echocardiographic Ejection Fraction Estimation: Frame Encoding Strategies and Anatomical Auxiliary Supervision"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Wang, May Dongmei"],"dc:contributor.committeemember":["Coskun, Ahmet","Dasi, Lakshmi"],"dc:contributor.other":["College of Engineering","Wallace H. Coulter Department of Biomedical Engineering"],"dc:creator":["Wang, Shaunna"],"dc:date.accessioned":["2026-09-23T19:03:40Z"],"dc:date.available":["2026-09-23T19:03:40Z"],"dc:date.created":["2026-08"],"dc:date.issued":["2026-08"],"dc:date.submitted":["August 2026"],"dc:date.updated":["2026-09-23T19:03:41Z"],"dc:description.abstract":["Automated estimation of left ventricular ejection fraction from echocardiographic video could reduce the time and variability associated with manual assessment. This thesis investigates how frame-encoding strategies and anatomical auxiliary supervision affect a lightweight six-layer transformer trained on 10,030 videos from EchoNet-Dynamic. Four frame encoders were evaluated: a linear projection, an ImageNet-pretrained ResNet-50, an adjacent-frame contrastive encoder, and a same-video contrastive encoder. A separately trained U-Net achieved a validation Dice score of 0.936 on expert-annotated end-diastolic and end-systolic frames and generated ventricular cavity masks, normalized cavity areas, and frame-to-frame area changes as auxiliary training targets. Among the evaluated encoders, the linear projection provided the strongest and most consistent regression performance. It also supported the strongest alignment with the generated anatomical targets, with auxiliary mask Dice scores of 0.88 to 0.91 and median area-trajectory correlations of 0.93 to 0.95 across more than 1,100 eligible test videos. However, stronger anatomical alignment did not produce a consistent or practically meaningful improvement in ejection fraction accuracy. These findings show that frame-encoder choice was the primary performance driver in the evaluated framework and that improved anatomical representation does not necessarily translate into improved clinical regression."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/82200"],"dc:language.iso":["English"],"dc:relation.advisorentity":["e8cb038f-ed3c-41d4-9159-0e51e2e069f1"],"dc:relation.ispartofseries":["Master of Science in Biomedical Engineering"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","da59be3c-3d0a-41da-91b9-ebe2ecc83b66"],"dc:relation.seriesentity":["f9608e55-1fc9-4f5c-bc9b-027467e51c31"],"dc:title":["Lightweight Transformers for Echocardiographic Ejection Fraction Estimation: Frame Encoding Strategies and Anatomical Auxiliary Supervision"],"dc:type":["Text","Thesis (Masters Degree)"],"dspace:entity.type":["Publication"],"person:identifier.orcid":["0009-0006-4736-7012"],"thesis:degree_college":["College of Engineering"],"thesis:degree_department":["Biomedical Engineering (Joint GT/Emory Department)"],"thesis:degree_name":["Biomedical Engineering, MS"],"thesis:institution_name":["Georgia Institute of Technology"]},"updated_at":"2026-11-19T04:54:06Z"}