{"id":{"repo_id":"gatech","oai_identifier":"oai:repository.gatech.edu:1853/82241"},"canonical_url":"https://search.ndltd.org/etd/gatech/oai:repository.gatech.edu:1853/82241","repository":{"repo_id":"gatech","name":"Georgia Tech","base_url":"https://repository.gatech.edu/server/oai/request"},"display":{"title":"Experimental and Numerical Investigation of Neutral Buoyancy Testing for In-Orbit Refueling","abstract":"In-orbit refueling requires transferring propellant between tanks in microgravity, and the fluid dynamics of that transfer are studied almost entirely on drop towers, parabolic flights, and orbiting platforms that are costly and slow. Plateau’s neutral-buoyancy method, which suspends one liquid inside a second immiscible liquid of matched density, offers a benchtop alternative, and this work asks whether it also reproduces the dynamic conditions under which a filling jet destabilizes. A benchtop neutral-buoyancy experiment and a matching axisymmetric two-phase solver were used, with the solver first validated against microgravity drop-tower data, reproducing published critical Weber numbers for jet breakup across a range of initial fill heights. In the neutrally buoyant system the jet requires up to four times greater momentum to penetrate the interface than in true microgravity, showing that density matching reproduces the static, capillary-dominated shape of a microgravity interface but not its dynamic behavior. Both systems nevertheless destabilize through the same sequence of flow morphologies. The jet inflates a bulb above the interface, and that bulb stays connected to the bath through a narrow neck carrying a counter-flow that returns liquid around the rising jet. Below the critical condition the neck holds a steady width and returns a substantial fraction of the injected flux, so the bulb settles into a steady shape and the interface stops advancing. At the critical condition the neck contracts until the return flow stops, all injected liquid is retained, and the bulb grows without bound. Only afterward do the two systems differ: the microgravity neck severs and sheds droplets, while the viscous outer liquid keeps the neutrally buoyant neck from ever breaking. Plateau’s method therefore remains a valuable, low-cost tool for investigating the morphology and physical mechanism of interface breakdown, even though it cannot directly predict the critical flow rate in microgravity.","abstract_html":"In-orbit refueling requires transferring propellant between tanks in microgravity, and the fluid dynamics of that transfer are studied almost entirely on drop towers, parabolic flights, and orbiting platforms that are costly and slow. Plateau’s neutral-buoyancy method, which suspends one liquid inside a second immiscible liquid of matched density, offers a benchtop alternative, and this work asks whether it also reproduces the dynamic conditions under which a filling jet destabilizes. A benchtop neutral-buoyancy experiment and a matching axisymmetric two-phase solver were used, with the solver first validated against microgravity drop-tower data, reproducing published critical Weber numbers for jet breakup across a range of initial fill heights. In the neutrally buoyant system the jet requires up to four times greater momentum to penetrate the interface than in true microgravity, showing that density matching reproduces the static, capillary-dominated shape of a microgravity interface but not its dynamic behavior. Both systems nevertheless destabilize through the same sequence of flow morphologies. The jet inflates a bulb above the interface, and that bulb stays connected to the bath through a narrow neck carrying a counter-flow that returns liquid around the rising jet. Below the critical condition the neck holds a steady width and returns a substantial fraction of the injected flux, so the bulb settles into a steady shape and the interface stops advancing. At the critical condition the neck contracts until the return flow stops, all injected liquid is retained, and the bulb grows without bound. Only afterward do the two systems differ: the microgravity neck severs and sheds droplets, while the viscous outer liquid keeps the neutrally buoyant neck from ever breaking. Plateau’s method therefore remains a valuable, low-cost tool for investigating the morphology and physical mechanism of interface breakdown, even though it cannot directly predict the critical flow rate in microgravity.","abstract_has_math":false,"creators":["Brown, Joseph Walker"],"institution":"Georgia Institute of Technology","degree_name":"Aerospace Engineering, MS","degree_level":null,"degree_discipline":null,"degree_department":"Aerospace Engineering","school":null,"contributors":[],"advisors":["Romero-Calvo, Álvaro"],"committee_chairs":[],"committee_members":["Oefelein, Joseph","Schatz, Michael"],"year":2026,"date_issued":"2026-05","date_published":"2026-05","updated_at":"2026-11-19T05:09:57Z","subjects":[],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1853/82241","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1853/82241","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://repository.gatech.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Arepository.gatech.edu%3A1853%2F82241","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Romero-Calvo, Álvaro"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Oefelein, Joseph","Schatz, Michael"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["College of Engineering","Daniel Guggenheim School of Aerospace Engineering"]},{"key":"dc:creator","label":"Author","values":["Brown, Joseph Walker"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-09-23T19:09:58Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-09-23T19:09:58Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2026-05"]},{"key":"dc:date.issued","label":"Date","values":["2026-05"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2026"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2026-09-23T19:09:59Z"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["6101525f-2add-4f37-ad67-dd54ea6ecf4d"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Master of Science in Aerospace Engineering"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["7c022d60-21d5-497c-b552-95e489a06569","a348b767-ea7e-4789-af1f-1f1d5925fb65"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["09844fbb-b7d9-45e2-95de-849e434a6abc"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis (Masters Degree)"]},{"key":"thesis:degree_college","label":"Thesis Degree College","values":["College of Engineering"]},{"key":"thesis:degree_department","label":"Department","values":["Aerospace Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Aerospace Engineering, MS"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Georgia Institute of Technology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1853/82241"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In-orbit refueling requires transferring propellant between tanks in microgravity, and the fluid dynamics of that transfer are studied almost entirely on drop towers, parabolic flights, and orbiting platforms that are costly and slow. Plateau’s neutral-buoyancy method, which suspends one liquid inside a second immiscible liquid of matched density, offers a benchtop alternative, and this work asks whether it also reproduces the dynamic conditions under which a filling jet destabilizes. A benchtop neutral-buoyancy experiment and a matching axisymmetric two-phase solver were used, with the solver first validated against microgravity drop-tower data, reproducing published critical Weber numbers for jet breakup across a range of initial fill heights. In the neutrally buoyant system the jet requires up to four times greater momentum to penetrate the interface than in true microgravity, showing that density matching reproduces the static, capillary-dominated shape of a microgravity interface but not its dynamic behavior. Both systems nevertheless destabilize through the same sequence of flow morphologies. The jet inflates a bulb above the interface, and that bulb stays connected to the bath through a narrow neck carrying a counter-flow that returns liquid around the rising jet. Below the critical condition the neck holds a steady width and returns a substantial fraction of the injected flux, so the bulb settles into a steady shape and the interface stops advancing. At the critical condition the neck contracts until the return flow stops, all injected liquid is retained, and the bulb grows without bound. Only afterward do the two systems differ: the microgravity neck severs and sheds droplets, while the viscous outer liquid keeps the neutrally buoyant neck from ever breaking. Plateau’s method therefore remains a valuable, low-cost tool for investigating the morphology and physical mechanism of interface breakdown, even though it cannot directly predict the critical flow rate in microgravity."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Experimental and Numerical Investigation of Neutral Buoyancy Testing for In-Orbit Refueling"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Romero-Calvo, Álvaro"],"dc:contributor.committeemember":["Oefelein, Joseph","Schatz, Michael"],"dc:contributor.other":["College of Engineering","Daniel Guggenheim School of Aerospace Engineering"],"dc:creator":["Brown, Joseph Walker"],"dc:date.accessioned":["2026-09-23T19:09:58Z"],"dc:date.available":["2026-09-23T19:09:58Z"],"dc:date.created":["2026-05"],"dc:date.issued":["2026-05"],"dc:date.submitted":["May 2026"],"dc:date.updated":["2026-09-23T19:09:59Z"],"dc:description.abstract":["In-orbit refueling requires transferring propellant between tanks in microgravity, and the fluid dynamics of that transfer are studied almost entirely on drop towers, parabolic flights, and orbiting platforms that are costly and slow. Plateau’s neutral-buoyancy method, which suspends one liquid inside a second immiscible liquid of matched density, offers a benchtop alternative, and this work asks whether it also reproduces the dynamic conditions under which a filling jet destabilizes. A benchtop neutral-buoyancy experiment and a matching axisymmetric two-phase solver were used, with the solver first validated against microgravity drop-tower data, reproducing published critical Weber numbers for jet breakup across a range of initial fill heights. In the neutrally buoyant system the jet requires up to four times greater momentum to penetrate the interface than in true microgravity, showing that density matching reproduces the static, capillary-dominated shape of a microgravity interface but not its dynamic behavior. Both systems nevertheless destabilize through the same sequence of flow morphologies. The jet inflates a bulb above the interface, and that bulb stays connected to the bath through a narrow neck carrying a counter-flow that returns liquid around the rising jet. Below the critical condition the neck holds a steady width and returns a substantial fraction of the injected flux, so the bulb settles into a steady shape and the interface stops advancing. At the critical condition the neck contracts until the return flow stops, all injected liquid is retained, and the bulb grows without bound. Only afterward do the two systems differ: the microgravity neck severs and sheds droplets, while the viscous outer liquid keeps the neutrally buoyant neck from ever breaking. Plateau’s method therefore remains a valuable, low-cost tool for investigating the morphology and physical mechanism of interface breakdown, even though it cannot directly predict the critical flow rate in microgravity."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1853/82241"],"dc:language.iso":["English"],"dc:relation.advisorentity":["6101525f-2add-4f37-ad67-dd54ea6ecf4d"],"dc:relation.ispartofseries":["Master of Science in Aerospace Engineering"],"dc:relation.orgunit":["7c022d60-21d5-497c-b552-95e489a06569","a348b767-ea7e-4789-af1f-1f1d5925fb65"],"dc:relation.seriesentity":["09844fbb-b7d9-45e2-95de-849e434a6abc"],"dc:title":["Experimental and Numerical Investigation of Neutral Buoyancy Testing for In-Orbit Refueling"],"dc:type":["Text","Thesis (Masters Degree)"],"dspace:entity.type":["Publication"],"thesis:degree_college":["College of Engineering"],"thesis:degree_department":["Aerospace Engineering"],"thesis:degree_name":["Aerospace Engineering, MS"],"thesis:institution_name":["Georgia Institute of Technology"]},"updated_at":"2026-11-19T05:09:57Z"}