{"id":{"repo_id":"glasgow","oai_identifier":"oai:theses.gla.ac.uk:71780"},"canonical_url":"https://search.ndltd.org/etd/glasgow/oai:theses.gla.ac.uk:71780","repository":{"repo_id":"glasgow","name":"University of Glasgow","base_url":"https://theses.gla.ac.uk/cgi/oai2"},"display":{"title":"The role of peripheral quantitative computed tomography at the ultra-distal radius in the assessment and management of osteoporosis","abstract":"Osteo-densitometry has some well defined roles in the management of osteoporosis. This thesis examined the role of a new technique, peripheral quantitative computed tomography (pQCT) at the ultra-distal radius, which quantifies trabecular and cortical bone mineral density (BMD) separately through a volumetric measurement. Comparison was made with dual energy X-ray absorptiometry (DXA), and calcaneal ultrasound attenuation (BUA) and velocity (VOS) in some studies. The precision [expressed as the co-efficient of variation (CV)] of pQCT in young females was 1.24%, 1.33%, 1.58% and 1.88% for total (Qtot), trabecular (Qtrab), subcortical (Qscort) and cortical (Qcort) BMD respectively. The precision was improved to these figures by minimising the difference in voxel numbers between repeat scans, a strategy which was thereafter utilised to aid repositioning in follow-up scans. (Abstract shortened by ProQuest.).","abstract_html":"Osteo-densitometry has some well defined roles in the management of osteoporosis. This thesis examined the role of a new technique, peripheral quantitative computed tomography (pQCT) at the ultra-distal radius, which quantifies trabecular and cortical bone mineral density (BMD) separately through a volumetric measurement. Comparison was made with dual energy X-ray absorptiometry (DXA), and calcaneal ultrasound attenuation (BUA) and velocity (VOS) in some studies. The precision [expressed as the co-efficient of variation (CV)] of pQCT in young females was 1.24%, 1.33%, 1.58% and 1.88% for total (Qtot), trabecular (Qtrab), subcortical (Qscort) and cortical (Qcort) BMD respectively. The precision was improved to these figures by minimising the difference in voxel numbers between repeat scans, a strategy which was thereafter utilised to aid repositioning in follow-up scans. (Abstract shortened by ProQuest.).","abstract_has_math":false,"creators":["Martin, James Clason"],"institution":"University of Glasgow","degree_name":null,"degree_level":"MD","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1997,"date_issued":"1997","date_published":"1997","updated_at":"2026-11-19T08:27:20Z","subjects":["R Medicine (General)","T Technology (General)"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.5525/gla.thesis.71780","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.5525/gla.thesis.71780","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","download_url":"https://theses.gla.ac.uk/71780/1/10391422.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://theses.gla.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Atheses.gla.ac.uk%3A71780","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Martin, James Clason"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1997"]},{"key":"dc:date.issued","label":"Date","values":["1997"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Department not provided."]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Glasgow"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://theses.gla.ac.uk/71780/"]},{"key":"dc:relation.isreferencedby.uri","label":"Dc Relation Isreferencedby URI","values":["https://gla.on.worldcat.org/oclc/181680248"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["MD"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["R Medicine (General)","T Technology (General)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.5525/gla.thesis.71780"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://theses.gla.ac.uk/71780/1/10391422.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Osteo-densitometry has some well defined roles in the management of osteoporosis. This thesis examined the role of a new technique, peripheral quantitative computed tomography (pQCT) at the ultra-distal radius, which quantifies trabecular and cortical bone mineral density (BMD) separately through a volumetric measurement. Comparison was made with dual energy X-ray absorptiometry (DXA), and calcaneal ultrasound attenuation (BUA) and velocity (VOS) in some studies. The precision [expressed as the co-efficient of variation (CV)] of pQCT in young females was 1.24%, 1.33%, 1.58% and 1.88% for total (Qtot), trabecular (Qtrab), subcortical (Qscort) and cortical (Qcort) BMD respectively. The precision was improved to these figures by minimising the difference in voxel numbers between repeat scans, a strategy which was thereafter utilised to aid repositioning in follow-up scans. (Abstract shortened by ProQuest.)."]},{"key":"dc:format","label":"Dc Format","values":["pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["The role of peripheral quantitative computed tomography at the ultra-distal radius in the assessment and management of osteoporosis"]}]}],"canonical_facts":{"dc:creator":["Martin, James Clason"],"dc:date":["1997"],"dc:date.issued":["1997"],"dc:description.abstract":["Osteo-densitometry has some well defined roles in the management of osteoporosis. This thesis examined the role of a new technique, peripheral quantitative computed tomography (pQCT) at the ultra-distal radius, which quantifies trabecular and cortical bone mineral density (BMD) separately through a volumetric measurement. Comparison was made with dual energy X-ray absorptiometry (DXA), and calcaneal ultrasound attenuation (BUA) and velocity (VOS) in some studies. The precision [expressed as the co-efficient of variation (CV)] of pQCT in young females was 1.24%, 1.33%, 1.58% and 1.88% for total (Qtot), trabecular (Qtrab), subcortical (Qscort) and cortical (Qcort) BMD respectively. The precision was improved to these figures by minimising the difference in voxel numbers between repeat scans, a strategy which was thereafter utilised to aid repositioning in follow-up scans. (Abstract shortened by ProQuest.)."],"dc:format":["pdf"],"dc:identifier.doi":["10.5525/gla.thesis.71780"],"dc:identifier.uri":["https://theses.gla.ac.uk/71780/1/10391422.pdf"],"dc:language":["en"],"dc:publisher.department":["Department not provided."],"dc:publisher.institution":["University of Glasgow"],"dc:relation.isreferencedby":["https://theses.gla.ac.uk/71780/"],"dc:relation.isreferencedby.uri":["https://gla.on.worldcat.org/oclc/181680248"],"dc:subject":["R Medicine (General)","T Technology (General)"],"dcterms:accessrights":["public"],"dc:title":["The role of peripheral quantitative computed tomography at the ultra-distal radius in the assessment and management of osteoporosis"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["MD"]},"updated_at":"2026-11-19T08:27:20Z"}