{"id":{"repo_id":"glasgow","oai_identifier":"oai:theses.gla.ac.uk:72168"},"canonical_url":"https://search.ndltd.org/etd/glasgow/oai:theses.gla.ac.uk:72168","repository":{"repo_id":"glasgow","name":"University of Glasgow","base_url":"https://theses.gla.ac.uk/cgi/oai2"},"display":{"title":"A study of priming processes in a centrifugal pump","abstract":"A search through literature reveals that there is no method for converting a standard centrifugal pump with a shrouded impeller, to self-priming operation without the use of valves or large loss in efficiency. A review of work carried out by Dr. Ing. A. Welte in Germany shows that, in the case of open shrouded impellers the pump operation is subject to instability in early stages of priming, if the re-fluxing jet is directed against the direction of rotation of the impeller. The conclusions of this work are, that the maximum attainable vacuum is a direct function of the impeller speed alone, and the air pumping capacity depends not only on the impeller width but also on the method of introducing the recirculating fluid. Furthermore the turbulent nature of flow renders it unsuitable for theoretical treatment. The investigation described in the thesis is carried out in two stages. The first, a feasibility study, is concerned with the alternative methods for energising a mixture of air and water by an impeller. It is found that the best method is by directing a jet at right angles against the suction end shroud of the impeller. An investigation of the jet positioning and casing geometry leads to the conclusion that the jet must be placed 180","abstract_html":"A search through literature reveals that there is no method for converting a standard centrifugal pump with a shrouded impeller, to self-priming operation without the use of valves or large loss in efficiency. A review of work carried out by Dr. Ing. A. Welte in Germany shows that, in the case of open shrouded impellers the pump operation is subject to instability in early stages of priming, if the re-fluxing jet is directed against the direction of rotation of the impeller. The conclusions of this work are, that the maximum attainable vacuum is a direct function of the impeller speed alone, and the air pumping capacity depends not only on the impeller width but also on the method of introducing the recirculating fluid. Furthermore the turbulent nature of flow renders it unsuitable for theoretical treatment. The investigation described in the thesis is carried out in two stages. The first, a feasibility study, is concerned with the alternative methods for energising a mixture of air and water by an impeller. It is found that the best method is by directing a jet at right angles against the suction end shroud of the impeller. An investigation of the jet positioning and casing geometry leads to the conclusion that the jet must be placed 180","abstract_has_math":false,"creators":["Rachman, D"],"institution":"University of Glasgow","degree_name":null,"degree_level":"MSc(R)","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1966,"date_issued":"1966","date_published":"1966","updated_at":"2026-11-19T08:27:39Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://theses.gla.ac.uk/72168/1/10645970.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://theses.gla.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Atheses.gla.ac.uk%3A72168","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Rachman, D"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1966"]},{"key":"dc:date.issued","label":"Date","values":["1966"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["ProQuest Dissertations & Theses,"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Department not provided."]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Glasgow"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://theses.gla.ac.uk/72168/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["MSc(R)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://theses.gla.ac.uk/72168/1/10645970.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A search through literature reveals that there is no method for converting a standard centrifugal pump with a shrouded impeller, to self-priming operation without the use of valves or large loss in efficiency. A review of work carried out by Dr. Ing. A. Welte in Germany shows that, in the case of open shrouded impellers the pump operation is subject to instability in early stages of priming, if the re-fluxing jet is directed against the direction of rotation of the impeller. The conclusions of this work are, that the maximum attainable vacuum is a direct function of the impeller speed alone, and the air pumping capacity depends not only on the impeller width but also on the method of introducing the recirculating fluid. Furthermore the turbulent nature of flow renders it unsuitable for theoretical treatment. The investigation described in the thesis is carried out in two stages. The first, a feasibility study, is concerned with the alternative methods for energising a mixture of air and water by an impeller. It is found that the best method is by directing a jet at right angles against the suction end shroud of the impeller. An investigation of the jet positioning and casing geometry leads to the conclusion that the jet must be placed 180"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["A study of priming processes in a centrifugal pump"]}]}],"canonical_facts":{"dc:creator":["Rachman, D"],"dc:date":["1966"],"dc:date.issued":["1966"],"dc:description.abstract":["A search through literature reveals that there is no method for converting a standard centrifugal pump with a shrouded impeller, to self-priming operation without the use of valves or large loss in efficiency. A review of work carried out by Dr. Ing. A. Welte in Germany shows that, in the case of open shrouded impellers the pump operation is subject to instability in early stages of priming, if the re-fluxing jet is directed against the direction of rotation of the impeller. The conclusions of this work are, that the maximum attainable vacuum is a direct function of the impeller speed alone, and the air pumping capacity depends not only on the impeller width but also on the method of introducing the recirculating fluid. Furthermore the turbulent nature of flow renders it unsuitable for theoretical treatment. The investigation described in the thesis is carried out in two stages. The first, a feasibility study, is concerned with the alternative methods for energising a mixture of air and water by an impeller. It is found that the best method is by directing a jet at right angles against the suction end shroud of the impeller. An investigation of the jet positioning and casing geometry leads to the conclusion that the jet must be placed 180"],"dc:format":["application/pdf"],"dc:identifier.uri":["https://theses.gla.ac.uk/72168/1/10645970.pdf"],"dc:language":["en"],"dc:publisher.commercial":["ProQuest Dissertations & Theses,"],"dc:publisher.department":["Department not provided."],"dc:publisher.institution":["University of Glasgow"],"dc:relation.isreferencedby":["https://theses.gla.ac.uk/72168/"],"dcterms:accessrights":["public"],"dc:title":["A study of priming processes in a centrifugal pump"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["MSc(R)"]},"updated_at":"2026-11-19T08:27:39Z"}