{"id":{"repo_id":"glasgow","oai_identifier":"oai:theses.gla.ac.uk:73499"},"canonical_url":"https://search.ndltd.org/etd/glasgow/oai:theses.gla.ac.uk:73499","repository":{"repo_id":"glasgow","name":"University of Glasgow","base_url":"https://theses.gla.ac.uk/cgi/oai2"},"display":{"title":"A study of impulse voltage breakdown with reference to the initiation of follow current","abstract":"The mechanism of follow current has been studied using a synthetic power source In conjunction with a Marx Impulse generator circuit, and air gaps of up to 1.6 cm. The performance of the circuit has been established analytically and experimentally, and the suitability of synthetic power circuits for follow current studies has been confirmed by the results of this investigation. A resistance divider with Inherent voltage limiting characteristics was essential for recording the discharge voltage between the electrodes. A method was devised and was shown, both by analysis end experiment, to have the required characteristics. The experimental technique having been established, a study has been carried out of the effects of variation in power and impulse circuit parameters, and in electrode material, shape, spacing, and surface condition. Three types of follow current have been defined, and their mechanisms have been explained. A close relation has been shown to exist in many cases between the conditions under which the establishment of follow current is just possible, and those required for arc-glow and glow-arc transitions in the test gap. Criteria which determine the establishment of follow current have been derived; A large number of variables has been shown to be involved in this problem, and their relative importance has been discussed. Recommendations have been made for further studies, as well as for the control of variables in industrial tests.","abstract_html":"The mechanism of follow current has been studied using a synthetic power source In conjunction with a Marx Impulse generator circuit, and air gaps of up to 1.6 cm. The performance of the circuit has been established analytically and experimentally, and the suitability of synthetic power circuits for follow current studies has been confirmed by the results of this investigation. A resistance divider with Inherent voltage limiting characteristics was essential for recording the discharge voltage between the electrodes. A method was devised and was shown, both by analysis end experiment, to have the required characteristics. The experimental technique having been established, a study has been carried out of the effects of variation in power and impulse circuit parameters, and in electrode material, shape, spacing, and surface condition. Three types of follow current have been defined, and their mechanisms have been explained. A close relation has been shown to exist in many cases between the conditions under which the establishment of follow current is just possible, and those required for arc-glow and glow-arc transitions in the test gap. Criteria which determine the establishment of follow current have been derived; A large number of variables has been shown to be involved in this problem, and their relative importance has been discussed. Recommendations have been made for further studies, as well as for the control of variables in industrial tests.","abstract_has_math":false,"creators":["Alston, Livius Leonard"],"institution":"University of Glasgow","degree_name":null,"degree_level":"PhD","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1955,"date_issued":"1955","date_published":"1955","updated_at":"2026-11-19T08:28:47Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://theses.gla.ac.uk/73499/1/10656258.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://theses.gla.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Atheses.gla.ac.uk%3A73499","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Alston, Livius Leonard"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1955"]},{"key":"dc:date.issued","label":"Date","values":["1955"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["ProQuest Dissertations & Theses,"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Department not provided."]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Glasgow"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://theses.gla.ac.uk/73499/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["PhD"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://theses.gla.ac.uk/73499/1/10656258.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The mechanism of follow current has been studied using a synthetic power source In conjunction with a Marx Impulse generator circuit, and air gaps of up to 1.6 cm. The performance of the circuit has been established analytically and experimentally, and the suitability of synthetic power circuits for follow current studies has been confirmed by the results of this investigation. A resistance divider with Inherent voltage limiting characteristics was essential for recording the discharge voltage between the electrodes. A method was devised and was shown, both by analysis end experiment, to have the required characteristics. The experimental technique having been established, a study has been carried out of the effects of variation in power and impulse circuit parameters, and in electrode material, shape, spacing, and surface condition. Three types of follow current have been defined, and their mechanisms have been explained. A close relation has been shown to exist in many cases between the conditions under which the establishment of follow current is just possible, and those required for arc-glow and glow-arc transitions in the test gap. Criteria which determine the establishment of follow current have been derived; A large number of variables has been shown to be involved in this problem, and their relative importance has been discussed. Recommendations have been made for further studies, as well as for the control of variables in industrial tests."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["A study of impulse voltage breakdown with reference to the initiation of follow current"]}]}],"canonical_facts":{"dc:creator":["Alston, Livius Leonard"],"dc:date":["1955"],"dc:date.issued":["1955"],"dc:description.abstract":["The mechanism of follow current has been studied using a synthetic power source In conjunction with a Marx Impulse generator circuit, and air gaps of up to 1.6 cm. The performance of the circuit has been established analytically and experimentally, and the suitability of synthetic power circuits for follow current studies has been confirmed by the results of this investigation. A resistance divider with Inherent voltage limiting characteristics was essential for recording the discharge voltage between the electrodes. A method was devised and was shown, both by analysis end experiment, to have the required characteristics. The experimental technique having been established, a study has been carried out of the effects of variation in power and impulse circuit parameters, and in electrode material, shape, spacing, and surface condition. Three types of follow current have been defined, and their mechanisms have been explained. A close relation has been shown to exist in many cases between the conditions under which the establishment of follow current is just possible, and those required for arc-glow and glow-arc transitions in the test gap. Criteria which determine the establishment of follow current have been derived; A large number of variables has been shown to be involved in this problem, and their relative importance has been discussed. Recommendations have been made for further studies, as well as for the control of variables in industrial tests."],"dc:format":["application/pdf"],"dc:identifier.uri":["https://theses.gla.ac.uk/73499/1/10656258.pdf"],"dc:language":["en"],"dc:publisher.commercial":["ProQuest Dissertations & Theses,"],"dc:publisher.department":["Department not provided."],"dc:publisher.institution":["University of Glasgow"],"dc:relation.isreferencedby":["https://theses.gla.ac.uk/73499/"],"dcterms:accessrights":["public"],"dc:title":["A study of impulse voltage breakdown with reference to the initiation of follow current"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["PhD"]},"updated_at":"2026-11-19T08:28:47Z"}