{"id":{"repo_id":"glasgow","oai_identifier":"oai:theses.gla.ac.uk:75279"},"canonical_url":"https://search.ndltd.org/etd/glasgow/oai:theses.gla.ac.uk:75279","repository":{"repo_id":"glasgow","name":"University of Glasgow","base_url":"https://theses.gla.ac.uk/cgi/oai2"},"display":{"title":"Anatomical Study of the Canine Limbs in Relation to External Skeletal Fixation: Introduction and Delimitation of Safe, Hazardous and Unsafe Corridors","abstract":"An anatomical study of the canine limbs was carried out in order to identify, locate and measure the extent of the safe, hazardous and unsafe corridors for pin insertion for the use of external skeletal fixation. Topographical dissections and cross-sections of fresh anatomical specimens of canine limbs were used to localise important neurovascular structures and musculotendinous units and to measure the extent of the corridors. Safe corridors for external skeletal fixator pin insertion are clearly present in the eccentric bones of the canine lower limbs. Although no clear safe passages were identified in concentric bones of the upper limb, hazardous areas and lines are described as the safest for application of external fixation frames. The feasibility of the application of different fixator configurations through safe areas in the canine appendicular long bones is discussed. Some guidelines are given in order to allow the orthopaedic surgeon to follow sound anatomical principles of fixator application and to reduce the incidence of some avoidable complications.","abstract_html":"An anatomical study of the canine limbs was carried out in order to identify, locate and measure the extent of the safe, hazardous and unsafe corridors for pin insertion for the use of external skeletal fixation. Topographical dissections and cross-sections of fresh anatomical specimens of canine limbs were used to localise important neurovascular structures and musculotendinous units and to measure the extent of the corridors. Safe corridors for external skeletal fixator pin insertion are clearly present in the eccentric bones of the canine lower limbs. Although no clear safe passages were identified in concentric bones of the upper limb, hazardous areas and lines are described as the safest for application of external fixation frames. The feasibility of the application of different fixator configurations through safe areas in the canine appendicular long bones is discussed. Some guidelines are given in order to allow the orthopaedic surgeon to follow sound anatomical principles of fixator application and to reduce the incidence of some avoidable complications.","abstract_has_math":false,"creators":["Marti Herrero, Juan Manuel"],"institution":"University of Glasgow","degree_name":null,"degree_level":"MVetMed","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1993,"date_issued":"1993","date_published":"1993","updated_at":"2026-11-19T08:30:14Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://theses.gla.ac.uk/75279/1/13815443.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://theses.gla.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Atheses.gla.ac.uk%3A75279","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Marti Herrero, Juan Manuel"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1993"]},{"key":"dc:date.issued","label":"Date","values":["1993"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["ProQuest Dissertations & Theses,"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Department of Veterinary Surgery."]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Glasgow"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://theses.gla.ac.uk/75279/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["MVetMed"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://theses.gla.ac.uk/75279/1/13815443.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An anatomical study of the canine limbs was carried out in order to identify, locate and measure the extent of the safe, hazardous and unsafe corridors for pin insertion for the use of external skeletal fixation. Topographical dissections and cross-sections of fresh anatomical specimens of canine limbs were used to localise important neurovascular structures and musculotendinous units and to measure the extent of the corridors. Safe corridors for external skeletal fixator pin insertion are clearly present in the eccentric bones of the canine lower limbs. Although no clear safe passages were identified in concentric bones of the upper limb, hazardous areas and lines are described as the safest for application of external fixation frames. The feasibility of the application of different fixator configurations through safe areas in the canine appendicular long bones is discussed. Some guidelines are given in order to allow the orthopaedic surgeon to follow sound anatomical principles of fixator application and to reduce the incidence of some avoidable complications."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Anatomical Study of the Canine Limbs in Relation to External Skeletal Fixation: Introduction and Delimitation of Safe, Hazardous and Unsafe Corridors"]}]}],"canonical_facts":{"dc:creator":["Marti Herrero, Juan Manuel"],"dc:date":["1993"],"dc:date.issued":["1993"],"dc:description.abstract":["An anatomical study of the canine limbs was carried out in order to identify, locate and measure the extent of the safe, hazardous and unsafe corridors for pin insertion for the use of external skeletal fixation. Topographical dissections and cross-sections of fresh anatomical specimens of canine limbs were used to localise important neurovascular structures and musculotendinous units and to measure the extent of the corridors. Safe corridors for external skeletal fixator pin insertion are clearly present in the eccentric bones of the canine lower limbs. Although no clear safe passages were identified in concentric bones of the upper limb, hazardous areas and lines are described as the safest for application of external fixation frames. The feasibility of the application of different fixator configurations through safe areas in the canine appendicular long bones is discussed. Some guidelines are given in order to allow the orthopaedic surgeon to follow sound anatomical principles of fixator application and to reduce the incidence of some avoidable complications."],"dc:format":["application/pdf"],"dc:identifier.uri":["https://theses.gla.ac.uk/75279/1/13815443.pdf"],"dc:language":["en"],"dc:publisher.commercial":["ProQuest Dissertations & Theses,"],"dc:publisher.department":["Department of Veterinary Surgery."],"dc:publisher.institution":["University of Glasgow"],"dc:relation.isreferencedby":["https://theses.gla.ac.uk/75279/"],"dcterms:accessrights":["public"],"dc:title":["Anatomical Study of the Canine Limbs in Relation to External Skeletal Fixation: Introduction and Delimitation of Safe, Hazardous and Unsafe Corridors"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["MVetMed"]},"updated_at":"2026-11-19T08:30:14Z"}