{"id":{"repo_id":"glasgow","oai_identifier":"oai:theses.gla.ac.uk:8947"},"canonical_url":"https://search.ndltd.org/etd/glasgow/oai:theses.gla.ac.uk:8947","repository":{"repo_id":"glasgow","name":"University of Glasgow","base_url":"https://theses.gla.ac.uk/cgi/oai2"},"display":{"title":"Deep tissue in vivo quantitative optical biopsy","abstract":"The study of vascular oxygen saturation has important implications in a range of diseases with which inflammation and hypoxia are associated. This thesis details advancements in multispectral imaging systems for in vivo optical biopsy, relating to new applications primarily for the localised measurement of blood oxygen saturation in vivo, and also fluorescence cellular imaging. A calibration-free oximetry technique, based on previous work in retinal oximetry, was developed for the purposes of microvascular oximetry analysis in deep tissue. A novel multispectral microscope was developed for imaging of the microvasculature, with annular back-illumination providing glint-free images and simplification of the optical oximetry model. This system was successfully employed for proof-of-concept oximetry in the mouse tendon, resulting in the first localised measurements of vascular hypoxia associated with acute inflammation. The tendon is of interest as it is affected by auto-immune inflammatory diseases such as rheumatoid arthritis. A further application of the oximetry algorithm to inflammation in the spinal cord of rats is described in this thesis, in which hypoxia associated with a rat model for multiple sclerosis was successfully quantified. The latter part of the thesis describes advancements made towards incorporating microendoscopic probes to the imaging system, extending the calibration-free oximetry technique to applications where minimally-invasive imaging is required. Preliminary ex vivo validation experiments in the mouse tendon are described. Finally, the minimally-invasive system was modified for multispectral fluorescence microscopy, and a novel technique for localised delivery of fluorophore-conjugated antibodies is described. Localised interventions and observations of immunological events is of interest to biologists as a greater understanding of immune-related disease can potentially be gained. Preliminary ex vivo experiments observing the binding of antibodies to T cells in the lymph node are described.","abstract_html":"The study of vascular oxygen saturation has important implications in a range of diseases with which inflammation and hypoxia are associated. This thesis details advancements in multispectral imaging systems for in vivo optical biopsy, relating to new applications primarily for the localised measurement of blood oxygen saturation in vivo, and also fluorescence cellular imaging. A calibration-free oximetry technique, based on previous work in retinal oximetry, was developed for the purposes of microvascular oximetry analysis in deep tissue. A novel multispectral microscope was developed for imaging of the microvasculature, with annular back-illumination providing glint-free images and simplification of the optical oximetry model. This system was successfully employed for proof-of-concept oximetry in the mouse tendon, resulting in the first localised measurements of vascular hypoxia associated with acute inflammation. The tendon is of interest as it is affected by auto-immune inflammatory diseases such as rheumatoid arthritis. A further application of the oximetry algorithm to inflammation in the spinal cord of rats is described in this thesis, in which hypoxia associated with a rat model for multiple sclerosis was successfully quantified. The latter part of the thesis describes advancements made towards incorporating microendoscopic probes to the imaging system, extending the calibration-free oximetry technique to applications where minimally-invasive imaging is required. Preliminary ex vivo validation experiments in the mouse tendon are described. Finally, the minimally-invasive system was modified for multispectral fluorescence microscopy, and a novel technique for localised delivery of fluorophore-conjugated antibodies is described. Localised interventions and observations of immunological events is of interest to biologists as a greater understanding of immune-related disease can potentially be gained. Preliminary ex vivo experiments observing the binding of antibodies to T cells in the lymph node are described.","abstract_has_math":false,"creators":["van der Putten, Marieke Anne"],"institution":"University of Glasgow","degree_name":null,"degree_level":"PhD","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018","date_published":"2018","updated_at":"2026-11-19T08:26:00Z","subjects":["QC Physics"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.5525/gla.thesis.8947","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.5525/gla.thesis.8947","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","download_url":"https://theses.gla.ac.uk/8947/1/2018vanderPuttenPhd.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://theses.gla.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Atheses.gla.ac.uk%3A8947","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["van der Putten, Marieke Anne"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018"]},{"key":"dc:date.issued","label":"Date","values":["2018"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Glasgow"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://theses.gla.ac.uk/8947/"]},{"key":"dc:relation.isreferencedby.uri","label":"Dc Relation Isreferencedby URI","values":["https://gla.on.worldcat.org/oclc/1547488006"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["PhD"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["QC Physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights.embargoreason","label":"Dc Rights Embargoreason","values":["Embargo expired. E-version uploaded 201222 AA. Research reported within the thesis was conducted in collaboration with Prof Ken Smith's group in the Institute of Neurology at UCL. Prof Smith is currently leading a co-authored publication on this work and we request that access to this thesis be restricted for a period of two years until this work has been published."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.5525/gla.thesis.8947"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://theses.gla.ac.uk/8947/1/2018vanderPuttenPhd.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The study of vascular oxygen saturation has important implications in a range of diseases with which inflammation and hypoxia are associated. This thesis details advancements in multispectral imaging systems for in vivo optical biopsy, relating to new applications primarily for the localised measurement of blood oxygen saturation in vivo, and also fluorescence cellular imaging. A calibration-free oximetry technique, based on previous work in retinal oximetry, was developed for the purposes of microvascular oximetry analysis in deep tissue. A novel multispectral microscope was developed for imaging of the microvasculature, with annular back-illumination providing glint-free images and simplification of the optical oximetry model. This system was successfully employed for proof-of-concept oximetry in the mouse tendon, resulting in the first localised measurements of vascular hypoxia associated with acute inflammation. The tendon is of interest as it is affected by auto-immune inflammatory diseases such as rheumatoid arthritis. A further application of the oximetry algorithm to inflammation in the spinal cord of rats is described in this thesis, in which hypoxia associated with a rat model for multiple sclerosis was successfully quantified. The latter part of the thesis describes advancements made towards incorporating microendoscopic probes to the imaging system, extending the calibration-free oximetry technique to applications where minimally-invasive imaging is required. Preliminary ex vivo validation experiments in the mouse tendon are described. Finally, the minimally-invasive system was modified for multispectral fluorescence microscopy, and a novel technique for localised delivery of fluorophore-conjugated antibodies is described. Localised interventions and observations of immunological events is of interest to biologists as a greater understanding of immune-related disease can potentially be gained. Preliminary ex vivo experiments observing the binding of antibodies to T cells in the lymph node are described."]},{"key":"dc:format","label":"Dc Format","values":["pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Deep tissue in vivo quantitative optical biopsy"]}]}],"canonical_facts":{"dc:creator":["van der Putten, Marieke Anne"],"dc:date":["2018"],"dc:date.issued":["2018"],"dc:description.abstract":["The study of vascular oxygen saturation has important implications in a range of diseases with which inflammation and hypoxia are associated. This thesis details advancements in multispectral imaging systems for in vivo optical biopsy, relating to new applications primarily for the localised measurement of blood oxygen saturation in vivo, and also fluorescence cellular imaging. A calibration-free oximetry technique, based on previous work in retinal oximetry, was developed for the purposes of microvascular oximetry analysis in deep tissue. A novel multispectral microscope was developed for imaging of the microvasculature, with annular back-illumination providing glint-free images and simplification of the optical oximetry model. This system was successfully employed for proof-of-concept oximetry in the mouse tendon, resulting in the first localised measurements of vascular hypoxia associated with acute inflammation. The tendon is of interest as it is affected by auto-immune inflammatory diseases such as rheumatoid arthritis. A further application of the oximetry algorithm to inflammation in the spinal cord of rats is described in this thesis, in which hypoxia associated with a rat model for multiple sclerosis was successfully quantified. The latter part of the thesis describes advancements made towards incorporating microendoscopic probes to the imaging system, extending the calibration-free oximetry technique to applications where minimally-invasive imaging is required. Preliminary ex vivo validation experiments in the mouse tendon are described. Finally, the minimally-invasive system was modified for multispectral fluorescence microscopy, and a novel technique for localised delivery of fluorophore-conjugated antibodies is described. Localised interventions and observations of immunological events is of interest to biologists as a greater understanding of immune-related disease can potentially be gained. Preliminary ex vivo experiments observing the binding of antibodies to T cells in the lymph node are described."],"dc:format":["pdf"],"dc:identifier.doi":["10.5525/gla.thesis.8947"],"dc:identifier.uri":["https://theses.gla.ac.uk/8947/1/2018vanderPuttenPhd.pdf"],"dc:language":["en"],"dc:publisher.institution":["University of Glasgow"],"dc:relation.isreferencedby":["https://theses.gla.ac.uk/8947/"],"dc:relation.isreferencedby.uri":["https://gla.on.worldcat.org/oclc/1547488006"],"dc:rights.embargoreason":["Embargo expired. E-version uploaded 201222 AA. Research reported within the thesis was conducted in collaboration with Prof Ken Smith's group in the Institute of Neurology at UCL. Prof Smith is currently leading a co-authored publication on this work and we request that access to this thesis be restricted for a period of two years until this work has been published."],"dc:subject":["QC Physics"],"dcterms:accessrights":["public"],"dc:title":["Deep tissue in vivo quantitative optical biopsy"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["PhD"]},"updated_at":"2026-11-19T08:26:00Z"}