{"id":{"repo_id":"greece","oai_identifier":"oai:10442/0843"},"canonical_url":"https://search.ndltd.org/etd/greece/oai:10442/0843","repository":{"repo_id":"greece","name":"Greek National Archive of PhD Theses","base_url":"https://phdtheses.ekt.gr/eadd_oai/request"},"display":{"title":"THE STUDY OF CATALYSIS BY GAS CHROMATOGRAPHIC METHODS","abstract":"THIS THESIS IS CONCERNED WITH THE USE AND FURTHER EXPLOITATION OF NOVEL GAS CHROMATOGRAPHIC TECHNIQUES IN THE STUDY OF CATALYSIS, DEALING WITH SOME EXPERIMENTAL AND MATHEMATICAL MODELLING ASPECTS OF THEIR ALIGNMENT. AN APPARATUS, WHICH IS CONSTRUCTED BY CONVENTIONAL MEANS, AND ENABLES SAMPLE VACANCY CHROMATOGRAPHY TO BE USED AS A COMPLETE AND FLEXIBLE ROUTINE METHOD, IS DESCRIBED. A SIMPLE DEVICE GENERATES CONTINUOUS STREAMS OF NITROGEN AND ORGANIC LIQUID REACTANT (HYDROCARBONS, CHLOROALKANES, ALCOHOLS) AT SOME STEADY CONCENTRATION. CONVERSIONS DOWN TO 2% CAN BE MEASURED. THE CONCENTRATION LEVEL IS CONTINUOUSLY MONITORED, THROUGH A SEPARATE LINE; THUS ANY INFORMATION OBTAINED CAN BE UNDISPUTABLY ASCRIBED TO THE BEHAVIOUR OF THE CATALYTIC SYSTEM UNDER INVESTIGATION. THIS LINE CAN BE ADDITIONALLY USED AS A SECOND SAMPLE VACANCY UNIT, AND THUS, IF REQUIRED, DUAL SAMPLE VACANCY CHROMATOGRAMS MAY BE OBTAINED. THE APPARATUS HAS BEEN DESIGNED SO THAT SAMPLE VACANCY, ELUTION AND STOPPED-FLOW REACTION CHROMATOGRAPHY CAN ALL BE APPLIED WITH NO ALTERATION. (SHORTENED)","abstract_html":"THIS THESIS IS CONCERNED WITH THE USE AND FURTHER EXPLOITATION OF NOVEL GAS CHROMATOGRAPHIC TECHNIQUES IN THE STUDY OF CATALYSIS, DEALING WITH SOME EXPERIMENTAL AND MATHEMATICAL MODELLING ASPECTS OF THEIR ALIGNMENT. AN APPARATUS, WHICH IS CONSTRUCTED BY CONVENTIONAL MEANS, AND ENABLES SAMPLE VACANCY CHROMATOGRAPHY TO BE USED AS A COMPLETE AND FLEXIBLE ROUTINE METHOD, IS DESCRIBED. A SIMPLE DEVICE GENERATES CONTINUOUS STREAMS OF NITROGEN AND ORGANIC LIQUID REACTANT (HYDROCARBONS, CHLOROALKANES, ALCOHOLS) AT SOME STEADY CONCENTRATION. CONVERSIONS DOWN TO 2% CAN BE MEASURED. THE CONCENTRATION LEVEL IS CONTINUOUSLY MONITORED, THROUGH A SEPARATE LINE; THUS ANY INFORMATION OBTAINED CAN BE UNDISPUTABLY ASCRIBED TO THE BEHAVIOUR OF THE CATALYTIC SYSTEM UNDER INVESTIGATION. THIS LINE CAN BE ADDITIONALLY USED AS A SECOND SAMPLE VACANCY UNIT, AND THUS, IF REQUIRED, DUAL SAMPLE VACANCY CHROMATOGRAMS MAY BE OBTAINED. THE APPARATUS HAS BEEN DESIGNED SO THAT SAMPLE VACANCY, ELUTION AND STOPPED-FLOW REACTION CHROMATOGRAPHY CAN ALL BE APPLIED WITH NO ALTERATION. (SHORTENED)","abstract_has_math":false,"creators":["Karabassis, I.","Καραμπάσης, Γιάννης"],"institution":"Institutes outside Greece","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1984,"date_issued":"1984","date_published":"1984","updated_at":"2026-11-18T20:20:34Z","subjects":["Κατάλυση, Ετερογενής","Κινητική αντιδράσεων","ΧΡΩΜΑΤΟΓΡΑΦΙΑ ΑΕΡΙΟΥ ΜΕ ΑΝΤΙΔΡΑΣΗ","ΧΡΩΜΑΤΟΓΡΑΦΙΑ, ΑΕΡΙΟΥ ΣΤΕΡΕΟΥ","ΧΡΩΜΑΤΟΓΡΑΦΙΚΟΙ ΑΝΤΙΔΡΑΣΤΗΡΕΣ ΡΟΗΣ","ALUMINO AND MODIFIED ALUMINO SURFACE","CATALYSIS GAS SOLID","CHROMATOGRAPHIC FLOW REACTORS","REACTION GAS CHROMATOGRAPHY","Reaction kinetics","REVERSED FLOW REACTION CHROMATOGRAPHY","SAMPLE VACANCY REACTION CHROMATOGRAPHY","STOPPED FLOW REACTION CHROMATOGRAPHY","Φυσικές Επιστήμες","Χημεία","Natural Sciences","Chemical Sciences"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/0843"],"render_values":[{"text":"10.12681/eadd/0843","href":"https://doi.org/10.12681/eadd/0843","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10442/hedi/0843","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/10442/hedi/0843","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://phdtheses.ekt.gr/eadd_oai/request?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3A10442%2F0843","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Karabassis, I.","Καραμπάσης, Γιάννης"]},{"key":"dc:creator.fathername","label":"Dc Creator Fathername","values":["Z."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1984"]},{"key":"dc:publisher","label":"Institution","values":["Institutes outside Greece","Ιδρύματα Εξωτερικού"]},{"key":"dc:type","label":"Dc Type","values":["PhD Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Κατάλυση, Ετερογενής","Κινητική αντιδράσεων","ΧΡΩΜΑΤΟΓΡΑΦΙΑ ΑΕΡΙΟΥ ΜΕ ΑΝΤΙΔΡΑΣΗ","ΧΡΩΜΑΤΟΓΡΑΦΙΑ, ΑΕΡΙΟΥ ΣΤΕΡΕΟΥ","ΧΡΩΜΑΤΟΓΡΑΦΙΚΟΙ ΑΝΤΙΔΡΑΣΤΗΡΕΣ ΡΟΗΣ","ALUMINO AND MODIFIED ALUMINO SURFACE","CATALYSIS GAS SOLID","CHROMATOGRAPHIC FLOW REACTORS","REACTION GAS CHROMATOGRAPHY","Reaction kinetics","REVERSED FLOW REACTION CHROMATOGRAPHY","SAMPLE VACANCY REACTION CHROMATOGRAPHY","STOPPED FLOW REACTION CHROMATOGRAPHY","Φυσικές Επιστήμες","Χημεία","Natural Sciences","Chemical Sciences"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/0843","http://hdl.handle.net/10442/hedi/0843"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["THIS THESIS IS CONCERNED WITH THE USE AND FURTHER EXPLOITATION OF NOVEL GAS CHROMATOGRAPHIC TECHNIQUES IN THE STUDY OF CATALYSIS, DEALING WITH SOME EXPERIMENTAL AND MATHEMATICAL MODELLING ASPECTS OF THEIR ALIGNMENT. AN APPARATUS, WHICH IS CONSTRUCTED BY CONVENTIONAL MEANS, AND ENABLES SAMPLE VACANCY CHROMATOGRAPHY TO BE USED AS A COMPLETE AND FLEXIBLE ROUTINE METHOD, IS DESCRIBED. A SIMPLE DEVICE GENERATES CONTINUOUS STREAMS OF NITROGEN AND ORGANIC LIQUID REACTANT (HYDROCARBONS, CHLOROALKANES, ALCOHOLS) AT SOME STEADY CONCENTRATION. CONVERSIONS DOWN TO 2% CAN BE MEASURED. THE CONCENTRATION LEVEL IS CONTINUOUSLY MONITORED, THROUGH A SEPARATE LINE; THUS ANY INFORMATION OBTAINED CAN BE UNDISPUTABLY ASCRIBED TO THE BEHAVIOUR OF THE CATALYTIC SYSTEM UNDER INVESTIGATION. THIS LINE CAN BE ADDITIONALLY USED AS A SECOND SAMPLE VACANCY UNIT, AND THUS, IF REQUIRED, DUAL SAMPLE VACANCY CHROMATOGRAMS MAY BE OBTAINED. THE APPARATUS HAS BEEN DESIGNED SO THAT SAMPLE VACANCY, ELUTION AND STOPPED-FLOW REACTION CHROMATOGRAPHY CAN ALL BE APPLIED WITH NO ALTERATION. (SHORTENED)"]},{"key":"dc:title","label":"Title","values":["THE STUDY OF CATALYSIS BY GAS CHROMATOGRAPHIC METHODS","ΜΕΛΕΤΗ ΚΑΤΑΛΥΣΗΣ ΜΕ ΑΕΡΙΟ ΧΡΩΜΑΤΟΓΡΑΦΙΚΕΣ ΜΕΘΟΔΟΥΣ"]}]}],"canonical_facts":{"dc:creator":["Karabassis, I.","Καραμπάσης, Γιάννης"],"dc:creator.fathername":["Z."],"dc:date":["1984"],"dc:description":["THIS THESIS IS CONCERNED WITH THE USE AND FURTHER EXPLOITATION OF NOVEL GAS CHROMATOGRAPHIC TECHNIQUES IN THE STUDY OF CATALYSIS, DEALING WITH SOME EXPERIMENTAL AND MATHEMATICAL MODELLING ASPECTS OF THEIR ALIGNMENT. AN APPARATUS, WHICH IS CONSTRUCTED BY CONVENTIONAL MEANS, AND ENABLES SAMPLE VACANCY CHROMATOGRAPHY TO BE USED AS A COMPLETE AND FLEXIBLE ROUTINE METHOD, IS DESCRIBED. A SIMPLE DEVICE GENERATES CONTINUOUS STREAMS OF NITROGEN AND ORGANIC LIQUID REACTANT (HYDROCARBONS, CHLOROALKANES, ALCOHOLS) AT SOME STEADY CONCENTRATION. CONVERSIONS DOWN TO 2% CAN BE MEASURED. THE CONCENTRATION LEVEL IS CONTINUOUSLY MONITORED, THROUGH A SEPARATE LINE; THUS ANY INFORMATION OBTAINED CAN BE UNDISPUTABLY ASCRIBED TO THE BEHAVIOUR OF THE CATALYTIC SYSTEM UNDER INVESTIGATION. THIS LINE CAN BE ADDITIONALLY USED AS A SECOND SAMPLE VACANCY UNIT, AND THUS, IF REQUIRED, DUAL SAMPLE VACANCY CHROMATOGRAMS MAY BE OBTAINED. THE APPARATUS HAS BEEN DESIGNED SO THAT SAMPLE VACANCY, ELUTION AND STOPPED-FLOW REACTION CHROMATOGRAPHY CAN ALL BE APPLIED WITH NO ALTERATION. (SHORTENED)"],"dc:identifier":["10.12681/eadd/0843","http://hdl.handle.net/10442/hedi/0843"],"dc:language":["eng"],"dc:publisher":["Institutes outside Greece","Ιδρύματα Εξωτερικού"],"dc:subject":["Κατάλυση, Ετερογενής","Κινητική αντιδράσεων","ΧΡΩΜΑΤΟΓΡΑΦΙΑ ΑΕΡΙΟΥ ΜΕ ΑΝΤΙΔΡΑΣΗ","ΧΡΩΜΑΤΟΓΡΑΦΙΑ, ΑΕΡΙΟΥ ΣΤΕΡΕΟΥ","ΧΡΩΜΑΤΟΓΡΑΦΙΚΟΙ ΑΝΤΙΔΡΑΣΤΗΡΕΣ ΡΟΗΣ","ALUMINO AND MODIFIED ALUMINO SURFACE","CATALYSIS GAS SOLID","CHROMATOGRAPHIC FLOW REACTORS","REACTION GAS CHROMATOGRAPHY","Reaction kinetics","REVERSED FLOW REACTION CHROMATOGRAPHY","SAMPLE VACANCY REACTION CHROMATOGRAPHY","STOPPED FLOW REACTION CHROMATOGRAPHY","Φυσικές Επιστήμες","Χημεία","Natural Sciences","Chemical Sciences"],"dc:title":["THE STUDY OF CATALYSIS BY GAS CHROMATOGRAPHIC METHODS","ΜΕΛΕΤΗ ΚΑΤΑΛΥΣΗΣ ΜΕ ΑΕΡΙΟ ΧΡΩΜΑΤΟΓΡΑΦΙΚΕΣ ΜΕΘΟΔΟΥΣ"],"dc:type":["PhD Thesis"]},"updated_at":"2026-11-18T20:20:34Z"}