{"id":{"repo_id":"greece","oai_identifier":"oai:10442/16081"},"canonical_url":"https://search.ndltd.org/etd/greece/oai:10442/16081","repository":{"repo_id":"greece","name":"Greek National Archive of PhD Theses","base_url":"https://phdtheses.ekt.gr/eadd_oai/request"},"display":{"title":"Μελέτη βιολογικών λειτουργιών με μοριακή τομογραφία φθορισμού","abstract":"Given that Optical Tomography is capable of quantitatively imaging the distribution of fluorophores and fluorescent proteins in vivo, there has been a great deal of interest in developing optical imaging systems under optimal experimental conditions. A novel system has been implemented that enables three dimensional (3D) imaging of fluorescent probes in whole animals using a non-contact set up, in parallel with a 3D surface reconstruction algorithm. The non-contact approach is a significant step forward in terms of experimental simplicity and provides comfort to the targeted animal. It allows the use of a CCD cameras as detector, resulting in large data sets, thus improving the accuracy of the inversion models used for quantitative 3D reconstruction of fluorochrome distribution, as well as facilitating imaging with higher spatial resolution. In this study the system is tested in determining the distribution of Green Fluorescent Protein (GFP) expressed by T-lymphocytes in the hCD2-GFP transgenic mouse model, thus demonstrating the potential of the system for studying the immunology-based studies. In vivo measurements have been carried in the GFP CLIP-170 mouse model.","abstract_html":"Given that Optical Tomography is capable of quantitatively imaging the distribution of fluorophores and fluorescent proteins in vivo, there has been a great deal of interest in developing optical imaging systems under optimal experimental conditions. A novel system has been implemented that enables three dimensional (3D) imaging of fluorescent probes in whole animals using a non-contact set up, in parallel with a 3D surface reconstruction algorithm. The non-contact approach is a significant step forward in terms of experimental simplicity and provides comfort to the targeted animal. It allows the use of a CCD cameras as detector, resulting in large data sets, thus improving the accuracy of the inversion models used for quantitative 3D reconstruction of fluorochrome distribution, as well as facilitating imaging with higher spatial resolution. In this study the system is tested in determining the distribution of Green Fluorescent Protein (GFP) expressed by T-lymphocytes in the hCD2-GFP transgenic mouse model, thus demonstrating the potential of the system for studying the immunology-based studies. In vivo measurements have been carried in the GFP CLIP-170 mouse model.","abstract_has_math":false,"creators":["Garofalakis, Anikitos","Γαροφαλάκης, Ανίκητος"],"institution":"University of Crete (UOC)","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007","date_published":"2007","updated_at":"2026-11-18T20:32:38Z","subjects":["Τομογραφία, Οπτική","Πρωτείνες, Πράσινη φθορίζουσα","Ποντίκια","Τ-λεμφοκύτταρα","Λέιζερ","Απεικόνιση, Ποσοτική","Τομογραφικές διατάξεις","Μη επεμβατική","Tomography, optical","Proteins, Green fluorescent","Mice","T-lymphocytes","Laser","Imaging, Quantitative","Tomographic system","Non-invasive","Φυσικές Επιστήμες","Φυσική","Natural Sciences","Physical Sciences"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/16081"],"render_values":[{"text":"10.12681/eadd/16081","href":"https://doi.org/10.12681/eadd/16081","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10442/hedi/16081","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/10442/hedi/16081","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://phdtheses.ekt.gr/eadd_oai/request?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3A10442%2F16081","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Garofalakis, Anikitos","Γαροφαλάκης, Ανίκητος"]},{"key":"dc:creator.fathername","label":"Dc Creator Fathername","values":["Emmanouil"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2007"]},{"key":"dc:publisher","label":"Institution","values":["University of Crete (UOC)","Πανεπιστήμιο Κρήτης"]},{"key":"dc:type","label":"Dc Type","values":["PhD Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Τομογραφία, Οπτική","Πρωτείνες, Πράσινη φθορίζουσα","Ποντίκια","Τ-λεμφοκύτταρα","Λέιζερ","Απεικόνιση, Ποσοτική","Τομογραφικές διατάξεις","Μη επεμβατική","Tomography, optical","Proteins, Green fluorescent","Mice","T-lymphocytes","Laser","Imaging, Quantitative","Tomographic system","Non-invasive","Φυσικές Επιστήμες","Φυσική","Natural Sciences","Physical Sciences"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/16081","http://hdl.handle.net/10442/hedi/16081"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Given that Optical Tomography is capable of quantitatively imaging the distribution of fluorophores and fluorescent proteins in vivo, there has been a great deal of interest in developing optical imaging systems under optimal experimental conditions. A novel system has been implemented that enables three dimensional (3D) imaging of fluorescent probes in whole animals using a non-contact set up, in parallel with a 3D surface reconstruction algorithm. The non-contact approach is a significant step forward in terms of experimental simplicity and provides comfort to the targeted animal. It allows the use of a CCD cameras as detector, resulting in large data sets, thus improving the accuracy of the inversion models used for quantitative 3D reconstruction of fluorochrome distribution, as well as facilitating imaging with higher spatial resolution. In this study the system is tested in determining the distribution of Green Fluorescent Protein (GFP) expressed by T-lymphocytes in the hCD2-GFP transgenic mouse model, thus demonstrating the potential of the system for studying the immunology-based studies. In vivo measurements have been carried in the GFP CLIP-170 mouse model."]},{"key":"dc:title","label":"Title","values":["Μελέτη βιολογικών λειτουργιών με μοριακή τομογραφία φθορισμού","Fluorescence molecular tomography and in-vivo applications"]}]}],"canonical_facts":{"dc:creator":["Garofalakis, Anikitos","Γαροφαλάκης, Ανίκητος"],"dc:creator.fathername":["Emmanouil"],"dc:date":["2007"],"dc:description":["Given that Optical Tomography is capable of quantitatively imaging the distribution of fluorophores and fluorescent proteins in vivo, there has been a great deal of interest in developing optical imaging systems under optimal experimental conditions. A novel system has been implemented that enables three dimensional (3D) imaging of fluorescent probes in whole animals using a non-contact set up, in parallel with a 3D surface reconstruction algorithm. The non-contact approach is a significant step forward in terms of experimental simplicity and provides comfort to the targeted animal. It allows the use of a CCD cameras as detector, resulting in large data sets, thus improving the accuracy of the inversion models used for quantitative 3D reconstruction of fluorochrome distribution, as well as facilitating imaging with higher spatial resolution. In this study the system is tested in determining the distribution of Green Fluorescent Protein (GFP) expressed by T-lymphocytes in the hCD2-GFP transgenic mouse model, thus demonstrating the potential of the system for studying the immunology-based studies. In vivo measurements have been carried in the GFP CLIP-170 mouse model."],"dc:identifier":["10.12681/eadd/16081","http://hdl.handle.net/10442/hedi/16081"],"dc:language":["eng"],"dc:publisher":["University of Crete (UOC)","Πανεπιστήμιο Κρήτης"],"dc:subject":["Τομογραφία, Οπτική","Πρωτείνες, Πράσινη φθορίζουσα","Ποντίκια","Τ-λεμφοκύτταρα","Λέιζερ","Απεικόνιση, Ποσοτική","Τομογραφικές διατάξεις","Μη επεμβατική","Tomography, optical","Proteins, Green fluorescent","Mice","T-lymphocytes","Laser","Imaging, Quantitative","Tomographic system","Non-invasive","Φυσικές Επιστήμες","Φυσική","Natural Sciences","Physical Sciences"],"dc:title":["Μελέτη βιολογικών λειτουργιών με μοριακή τομογραφία φθορισμού","Fluorescence molecular tomography and in-vivo applications"],"dc:type":["PhD Thesis"]},"updated_at":"2026-11-18T20:32:38Z"}