{"id":{"repo_id":"greece","oai_identifier":"oai:10442/18601"},"canonical_url":"https://search.ndltd.org/etd/greece/oai:10442/18601","repository":{"repo_id":"greece","name":"Greek National Archive of PhD Theses","base_url":"https://phdtheses.ekt.gr/eadd_oai/request"},"display":{"title":"Συγκριτική μελέτη και αξιολόγηση των διαφόρων τονομετρικών συστημάτων σε οφθαλμούς με μεταβολή του πάχους του κερατοειδούς μετά από διαθλαστική χειρουργική και σε οφθαλμούς με διαφόρου τύπου παθολογικά ευρήματα: υπερτονία και γλαύκωμα, κερατόκωνο, διαμπερή κερατοειδοπλαστική","abstract":"The purpose of this study was to evaluate a recently introduced tonometer (PASCAL) by comparing its measurements to those of the most commonly used tonometers such as the Goldmann tonometer and the non-contact air tonometer. We obtained IOP measurements in healthy eyes , as well as in eyes with different eye pathologies ( such as keratoconus, ocular hypertension, glaucoma) and also in eyes that had underwent surgical procedures such as refractive surgery or penetrating keratoplasty. Our results suggest that Pascal IOP measurements are less influenced by corneal characteristics and mainly from corneal thickness, and therefore Pascal could be better suited for monitoring IOP in both healthy and operated eyes.","abstract_html":"The purpose of this study was to evaluate a recently introduced tonometer (PASCAL) by comparing its measurements to those of the most commonly used tonometers such as the Goldmann tonometer and the non-contact air tonometer. We obtained IOP measurements in healthy eyes , as well as in eyes with different eye pathologies ( such as keratoconus, ocular hypertension, glaucoma) and also in eyes that had underwent surgical procedures such as refractive surgery or penetrating keratoplasty. Our results suggest that Pascal IOP measurements are less influenced by corneal characteristics and mainly from corneal thickness, and therefore Pascal could be better suited for monitoring IOP in both healthy and operated eyes.","abstract_has_math":false,"creators":["Papastergiou, Georgios","Παπαστεργίου, Γεώργιος"],"institution":"Democritus University of Thrace (DUTH)","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009","date_published":"2009","updated_at":"2026-11-18T20:33:28Z","subjects":["Γλαύκωμα","Τονόμετρο Pascal","Τονόμετρο Goldmann","Τονόμετρο δι' αέρος","Οφθαλμική υπερτονία","Διαμπερής κερατοειδοπλαστική","Κερατόκωνος","Διαθλαστική χειρουργική","Glaucoma","Pascal tonometer","Goldmann tonometer","Non-contact air tonometer","Ocular hypertension","Penetrating keratoplasty","Keratoconus","Refractive surgery","Ιατρική και Επιστήμες Υγείας","Κλινική Ιατρική","Medical and Health Sciences","Clinical Medicine"],"languages":["gre"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/18601"],"render_values":[{"text":"10.12681/eadd/18601","href":"https://doi.org/10.12681/eadd/18601","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10442/hedi/18601","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/10442/hedi/18601","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://phdtheses.ekt.gr/eadd_oai/request?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3A10442%2F18601","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Papastergiou, Georgios","Παπαστεργίου, Γεώργιος"]},{"key":"dc:creator.fathername","label":"Dc Creator Fathername","values":["Ioannis"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2009"]},{"key":"dc:publisher","label":"Institution","values":["Democritus University of Thrace (DUTH)","Δημοκρίτειο Πανεπιστήμιο Θράκης (ΔΠΘ)"]},{"key":"dc:type","label":"Dc Type","values":["PhD Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Γλαύκωμα","Τονόμετρο Pascal","Τονόμετρο Goldmann","Τονόμετρο δι' αέρος","Οφθαλμική υπερτονία","Διαμπερής κερατοειδοπλαστική","Κερατόκωνος","Διαθλαστική χειρουργική","Glaucoma","Pascal tonometer","Goldmann tonometer","Non-contact air tonometer","Ocular hypertension","Penetrating keratoplasty","Keratoconus","Refractive surgery","Ιατρική και Επιστήμες Υγείας","Κλινική Ιατρική","Medical and Health Sciences","Clinical Medicine"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["gre"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/18601","http://hdl.handle.net/10442/hedi/18601"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The purpose of this study was to evaluate a recently introduced tonometer (PASCAL) by comparing its measurements to those of the most commonly used tonometers such as the Goldmann tonometer and the non-contact air tonometer. We obtained IOP measurements in healthy eyes , as well as in eyes with different eye pathologies ( such as keratoconus, ocular hypertension, glaucoma) and also in eyes that had underwent surgical procedures such as refractive surgery or penetrating keratoplasty. Our results suggest that Pascal IOP measurements are less influenced by corneal characteristics and mainly from corneal thickness, and therefore Pascal could be better suited for monitoring IOP in both healthy and operated eyes.","Στόχος της παρούσας μελέτης ήταν η αξιολόγηση του νέου τονόμετρου Pascal μέσα από την σύγκριση των μετρήσεων του με εκείνες των σήμερα ευρέως διαδεδομένων τονομέτρων όπως το τονόμετρο Goldmann και το τονόμετρο δι΄άέρος. Πραγματοποιήσαμε μετρήσεις ενδοφθάλμιας πίεσης (ΕΟΠ) σε υγιείς οφθαλμούς , σε οφθαλμούς με παθολογίες όπως ο κερατόκωνος, η οφθαλμική υπερτονία και το γλαύκωμα, αλλά και σε οφθαλμούς που είχαν υποστεί χειρουργικές επεμβάσεις, όπως διαθλαστική χειρουργική ή διαμπερή κερατοειδοπλαστική. Τα ευρήματα μας δείχνουν ότι οι μετρήσεις του τονομέτρου Pascal επηρεάζονται λιγότερο από τα χαρακτηριστικά του κερατοειδούς και κυρίως από το πάχος του, και κατά συνέπεια το καινούργιο αυτό τονόμετρο φαίνεται να είναι πιο αξιόπιστο για την παρακολούθηση της ΕΟΠ τόσο σε υγιείς όσο και σε χειρουργημένους οφθαλμούς."]},{"key":"dc:title","label":"Title","values":["Συγκριτική μελέτη και αξιολόγηση των διαφόρων τονομετρικών συστημάτων σε οφθαλμούς με μεταβολή του πάχους του κερατοειδούς μετά από διαθλαστική χειρουργική και σε οφθαλμούς με διαφόρου τύπου παθολογικά ευρήματα: υπερτονία και γλαύκωμα, κερατόκωνο, διαμπερή κερατοειδοπλαστική","assesment of the different available tonometers in eyes with altered corneal thickness after refractive surgery and in eyes with different pathologies: ocular hypertension or glaucoma, ketatoconus, after penetrating keratoplasty"]}]}],"canonical_facts":{"dc:creator":["Papastergiou, Georgios","Παπαστεργίου, Γεώργιος"],"dc:creator.fathername":["Ioannis"],"dc:date":["2009"],"dc:description":["The purpose of this study was to evaluate a recently introduced tonometer (PASCAL) by comparing its measurements to those of the most commonly used tonometers such as the Goldmann tonometer and the non-contact air tonometer. We obtained IOP measurements in healthy eyes , as well as in eyes with different eye pathologies ( such as keratoconus, ocular hypertension, glaucoma) and also in eyes that had underwent surgical procedures such as refractive surgery or penetrating keratoplasty. Our results suggest that Pascal IOP measurements are less influenced by corneal characteristics and mainly from corneal thickness, and therefore Pascal could be better suited for monitoring IOP in both healthy and operated eyes.","Στόχος της παρούσας μελέτης ήταν η αξιολόγηση του νέου τονόμετρου Pascal μέσα από την σύγκριση των μετρήσεων του με εκείνες των σήμερα ευρέως διαδεδομένων τονομέτρων όπως το τονόμετρο Goldmann και το τονόμετρο δι΄άέρος. Πραγματοποιήσαμε μετρήσεις ενδοφθάλμιας πίεσης (ΕΟΠ) σε υγιείς οφθαλμούς , σε οφθαλμούς με παθολογίες όπως ο κερατόκωνος, η οφθαλμική υπερτονία και το γλαύκωμα, αλλά και σε οφθαλμούς που είχαν υποστεί χειρουργικές επεμβάσεις, όπως διαθλαστική χειρουργική ή διαμπερή κερατοειδοπλαστική. Τα ευρήματα μας δείχνουν ότι οι μετρήσεις του τονομέτρου Pascal επηρεάζονται λιγότερο από τα χαρακτηριστικά του κερατοειδούς και κυρίως από το πάχος του, και κατά συνέπεια το καινούργιο αυτό τονόμετρο φαίνεται να είναι πιο αξιόπιστο για την παρακολούθηση της ΕΟΠ τόσο σε υγιείς όσο και σε χειρουργημένους οφθαλμούς."],"dc:identifier":["10.12681/eadd/18601","http://hdl.handle.net/10442/hedi/18601"],"dc:language":["gre"],"dc:publisher":["Democritus University of Thrace (DUTH)","Δημοκρίτειο Πανεπιστήμιο Θράκης (ΔΠΘ)"],"dc:subject":["Γλαύκωμα","Τονόμετρο Pascal","Τονόμετρο Goldmann","Τονόμετρο δι' αέρος","Οφθαλμική υπερτονία","Διαμπερής κερατοειδοπλαστική","Κερατόκωνος","Διαθλαστική χειρουργική","Glaucoma","Pascal tonometer","Goldmann tonometer","Non-contact air tonometer","Ocular hypertension","Penetrating keratoplasty","Keratoconus","Refractive surgery","Ιατρική και Επιστήμες Υγείας","Κλινική Ιατρική","Medical and Health Sciences","Clinical Medicine"],"dc:title":["Συγκριτική μελέτη και αξιολόγηση των διαφόρων τονομετρικών συστημάτων σε οφθαλμούς με μεταβολή του πάχους του κερατοειδούς μετά από διαθλαστική χειρουργική και σε οφθαλμούς με διαφόρου τύπου παθολογικά ευρήματα: υπερτονία και γλαύκωμα, κερατόκωνο, διαμπερή κερατοειδοπλαστική","assesment of the different available tonometers in eyes with altered corneal thickness after refractive surgery and in eyes with different pathologies: ocular hypertension or glaucoma, ketatoconus, after penetrating keratoplasty"],"dc:type":["PhD Thesis"]},"updated_at":"2026-11-18T20:33:28Z"}