{"id":{"repo_id":"greece","oai_identifier":"oai:10442/18672"},"canonical_url":"https://search.ndltd.org/etd/greece/oai:10442/18672","repository":{"repo_id":"greece","name":"Greek National Archive of PhD Theses","base_url":"https://phdtheses.ekt.gr/eadd_oai/request"},"display":{"title":"Ανάπτυξη τεχνικών ανακατασκευής ιατρικών δεδομένων βασισμένη σε ένα σύστημα small-animal PET μέσω βελτιστοποίησης και σύγκρισης μεθόδων επεξεργασίας και ανάλυσης ιατρικής πληροφορίας","abstract":"Small animal imaging is the conjunctive ring between experimental research and clinical implementation. Positron Emission Tomography (PET) has proven a valuable tool for in vivo small animal functional imaging. Image reconstruction in PET uses the collected projection data of the object/patient under examination. The purpose of this study is to assess the performance of iterative reconstruction methods, using phantom data from a prototype small-animal PET system. The algorithms being compared are the simultaneous versions of ART (SART), EM-ML, ISRA and WLS and a new iterative algorithm being introduced under the short name ISWLS. In the second part of this thesis elastic or deformable models are studied. Various methods of parametric elastic models are presented, namely the classical snake, the gradient vector field snake (gvf-snake) and the topogy-adaptive snake (t-snake). Also presented the method of self-affine mapping system as an alternative of elastic models. Further a new comparison criterion for the self affine mapping system method is introduced. All methods are applied to retinal images with the purpose of segmenting the optical disk. Moreover the aforementioned methods are compared in terms of segmentation accuracy.","abstract_html":"Small animal imaging is the conjunctive ring between experimental research and clinical implementation. Positron Emission Tomography (PET) has proven a valuable tool for in vivo small animal functional imaging. Image reconstruction in PET uses the collected projection data of the object/patient under examination. The purpose of this study is to assess the performance of iterative reconstruction methods, using phantom data from a prototype small-animal PET system. The algorithms being compared are the simultaneous versions of ART (SART), EM-ML, ISRA and WLS and a new iterative algorithm being introduced under the short name ISWLS. In the second part of this thesis elastic or deformable models are studied. Various methods of parametric elastic models are presented, namely the classical snake, the gradient vector field snake (gvf-snake) and the topogy-adaptive snake (t-snake). Also presented the method of self-affine mapping system as an alternative of elastic models. Further a new comparison criterion for the self affine mapping system method is introduced. All methods are applied to retinal images with the purpose of segmenting the optical disk. Moreover the aforementioned methods are compared in terms of segmentation accuracy.","abstract_has_math":false,"creators":["Karalis, Evangelia","Κάραλη, Ευαγγελία"],"institution":"University of Patras","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010","date_published":"2010","updated_at":"2026-11-18T20:33:39Z","subjects":["Ιατρικά δεδομένα, Ανακατασκευή","Τομογραφία PET","Ζώα, Απεικόνιση μικρών","Ελαστικά μοντέλα","Επιστήμες Μηχανικού και Τεχνολογία","Επιστήμη Ηλεκτρολόγου Μηχανικού, Ηλεκτρονικού Μηχανικού, Μηχανικού Η/Υ","Engineering and Technology","Electrical Engineering, Electronic Engineering, Information Engineering"],"languages":["gre"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/18672"],"render_values":[{"text":"10.12681/eadd/18672","href":"https://doi.org/10.12681/eadd/18672","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10442/hedi/18672","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/10442/hedi/18672","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://phdtheses.ekt.gr/eadd_oai/request?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3A10442%2F18672","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Karalis, Evangelia","Κάραλη, Ευαγγελία"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010"]},{"key":"dc:publisher","label":"Institution","values":["University of Patras","Πανεπιστήμιο Πατρών"]},{"key":"dc:type","label":"Dc Type","values":["PhD Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Ιατρικά δεδομένα, Ανακατασκευή","Τομογραφία PET","Ζώα, Απεικόνιση μικρών","Ελαστικά μοντέλα","Επιστήμες Μηχανικού και Τεχνολογία","Επιστήμη Ηλεκτρολόγου Μηχανικού, Ηλεκτρονικού Μηχανικού, Μηχανικού Η/Υ","Engineering and Technology","Electrical Engineering, Electronic Engineering, Information Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["gre"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/18672","http://hdl.handle.net/10442/hedi/18672"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Small animal imaging is the conjunctive ring between experimental research and clinical implementation. Positron Emission Tomography (PET) has proven a valuable tool for in vivo small animal functional imaging. Image reconstruction in PET uses the collected projection data of the object/patient under examination. The purpose of this study is to assess the performance of iterative reconstruction methods, using phantom data from a prototype small-animal PET system. The algorithms being compared are the simultaneous versions of ART (SART), EM-ML, ISRA and WLS and a new iterative algorithm being introduced under the short name ISWLS. In the second part of this thesis elastic or deformable models are studied. Various methods of parametric elastic models are presented, namely the classical snake, the gradient vector field snake (gvf-snake) and the topogy-adaptive snake (t-snake). Also presented the method of self-affine mapping system as an alternative of elastic models. Further a new comparison criterion for the self affine mapping system method is introduced. All methods are applied to retinal images with the purpose of segmenting the optical disk. Moreover the aforementioned methods are compared in terms of segmentation accuracy.","Η παρούσα διδακτορική διατριβή αποτελεί μια μελέτη σύγκρισης και βελτιστοποίησης διάφορων αλγορίθμων ανακατασκευής δεδομένων, τα οποία προέρχονται από ένα πρότυπο σύστημα ΡΕΤ ικανό για απεικονίσεις μικρών ζώων. Η σύγκριση αφορά υπάρχοντες αλγορίθμους ανακατασκευής ενώ παρουσιάζεται και ένας νέος επαναληπτικός αλγόριθμος o ISWLS. Το δεύτερο μέρος της παρούσας διδακτορικής διατριβής ασχολείται με ένα άλλο σημαντικό στάδιο της επεξεργασίας ιατρικών δεδομένων την τμηματοποίηση της ιατρικής εικόνας. Παρουσιάζονται διάφορες τεχνικές παραμετρικών ελαστικών μοντέλων. Συγκεκριμένα παρουσιάζονται το κλασσικό μοντέλο φιδιού (snake), το μοντέλο gradient vector flow (gvf-snake) και τα t-snakes (topology-adaptive snakes). Επίσης παρουσιάζεται η μέθοδος self-affine mapping σαν μια εναλλακτική των παραπάνω παραμετρικών ελαστικών μοντέλων και εισάγεται ένα νέο κριτήριο σύγκλισής της. Όλες οι τεχνικές εφαρμόζονται σε οφθαλμικές εικόνες με σκοπό την τμηματοποίηση του οπτικού δίσκου."]},{"key":"dc:title","label":"Title","values":["Ανάπτυξη τεχνικών ανακατασκευής ιατρικών δεδομένων βασισμένη σε ένα σύστημα small-animal PET μέσω βελτιστοποίησης και σύγκρισης μεθόδων επεξεργασίας και ανάλυσης ιατρικής πληροφορίας","Medical image reconstruction methods for a prototype small-animal PET system based on optimization and comparative methods of medical information processing and analysis"]}]}],"canonical_facts":{"dc:creator":["Karalis, Evangelia","Κάραλη, Ευαγγελία"],"dc:date":["2010"],"dc:description":["Small animal imaging is the conjunctive ring between experimental research and clinical implementation. Positron Emission Tomography (PET) has proven a valuable tool for in vivo small animal functional imaging. Image reconstruction in PET uses the collected projection data of the object/patient under examination. The purpose of this study is to assess the performance of iterative reconstruction methods, using phantom data from a prototype small-animal PET system. The algorithms being compared are the simultaneous versions of ART (SART), EM-ML, ISRA and WLS and a new iterative algorithm being introduced under the short name ISWLS. In the second part of this thesis elastic or deformable models are studied. Various methods of parametric elastic models are presented, namely the classical snake, the gradient vector field snake (gvf-snake) and the topogy-adaptive snake (t-snake). Also presented the method of self-affine mapping system as an alternative of elastic models. Further a new comparison criterion for the self affine mapping system method is introduced. All methods are applied to retinal images with the purpose of segmenting the optical disk. Moreover the aforementioned methods are compared in terms of segmentation accuracy.","Η παρούσα διδακτορική διατριβή αποτελεί μια μελέτη σύγκρισης και βελτιστοποίησης διάφορων αλγορίθμων ανακατασκευής δεδομένων, τα οποία προέρχονται από ένα πρότυπο σύστημα ΡΕΤ ικανό για απεικονίσεις μικρών ζώων. Η σύγκριση αφορά υπάρχοντες αλγορίθμους ανακατασκευής ενώ παρουσιάζεται και ένας νέος επαναληπτικός αλγόριθμος o ISWLS. Το δεύτερο μέρος της παρούσας διδακτορικής διατριβής ασχολείται με ένα άλλο σημαντικό στάδιο της επεξεργασίας ιατρικών δεδομένων την τμηματοποίηση της ιατρικής εικόνας. Παρουσιάζονται διάφορες τεχνικές παραμετρικών ελαστικών μοντέλων. Συγκεκριμένα παρουσιάζονται το κλασσικό μοντέλο φιδιού (snake), το μοντέλο gradient vector flow (gvf-snake) και τα t-snakes (topology-adaptive snakes). Επίσης παρουσιάζεται η μέθοδος self-affine mapping σαν μια εναλλακτική των παραπάνω παραμετρικών ελαστικών μοντέλων και εισάγεται ένα νέο κριτήριο σύγκλισής της. Όλες οι τεχνικές εφαρμόζονται σε οφθαλμικές εικόνες με σκοπό την τμηματοποίηση του οπτικού δίσκου."],"dc:identifier":["10.12681/eadd/18672","http://hdl.handle.net/10442/hedi/18672"],"dc:language":["gre"],"dc:publisher":["University of Patras","Πανεπιστήμιο Πατρών"],"dc:subject":["Ιατρικά δεδομένα, Ανακατασκευή","Τομογραφία PET","Ζώα, Απεικόνιση μικρών","Ελαστικά μοντέλα","Επιστήμες Μηχανικού και Τεχνολογία","Επιστήμη Ηλεκτρολόγου Μηχανικού, Ηλεκτρονικού Μηχανικού, Μηχανικού Η/Υ","Engineering and Technology","Electrical Engineering, Electronic Engineering, Information Engineering"],"dc:title":["Ανάπτυξη τεχνικών ανακατασκευής ιατρικών δεδομένων βασισμένη σε ένα σύστημα small-animal PET μέσω βελτιστοποίησης και σύγκρισης μεθόδων επεξεργασίας και ανάλυσης ιατρικής πληροφορίας","Medical image reconstruction methods for a prototype small-animal PET system based on optimization and comparative methods of medical information processing and analysis"],"dc:type":["PhD Thesis"]},"updated_at":"2026-11-18T20:33:39Z"}