{"id":{"repo_id":"greece","oai_identifier":"oai:10442/1922"},"canonical_url":"https://search.ndltd.org/etd/greece/oai:10442/1922","repository":{"repo_id":"greece","name":"Greek National Archive of PhD Theses","base_url":"https://phdtheses.ekt.gr/eadd_oai/request"},"display":{"title":"Ο Η/Υ ΣΤΟ ΣΧΕΔΙΑΣΜΟ ΗΛΙΑΚΩΝ ΣΥΣΤΗΜΑΤΩΝ. ΕΠΙΠΕΔΑ ΠΕΡΙΓΡΑΦΗΣ ΚΑΙ ΟΡΙΑ ΑΞΙΟΠΙΣΤΙΑΣ","abstract":"METHODS OF SOLAR HEATING DESIGN WHICH VARY THE DESCRIPTION LEVEL ARE DEVELOPED AND COMPARED. INCLUDE A DETAILED SIMULATION, A SIMPLIFIED VERSION WHICH UTILIZES THE RELEVANT THERMAL NETWORK, AND AN EMPIRICAL SIGN TOOL BASED ON DIMENSIONALANALYSIS. IN EACH CASE, THE RESULTING COMPUTER CODE IS USED IN PARAMETRIC STUDY OF THE SAME EXAMPLE DESIGN CASE, NAMELY, A SIMPLE SOLAR SPACE HEATING INSTALLATION. COMPARISON OF THE THREE METHODS, BASED ON CALCULATIONS INVOLVING THREE WIDELY SPACED GREEK CITIES, SHOWS A MAXIMUM DIFFERENCE OF LESS THAN 6% IN THE PREDICTION OF THE ANNUAL SOLAR FRACTION.","abstract_html":"METHODS OF SOLAR HEATING DESIGN WHICH VARY THE DESCRIPTION LEVEL ARE DEVELOPED AND COMPARED. INCLUDE A DETAILED SIMULATION, A SIMPLIFIED VERSION WHICH UTILIZES THE RELEVANT THERMAL NETWORK, AND AN EMPIRICAL SIGN TOOL BASED ON DIMENSIONALANALYSIS. IN EACH CASE, THE RESULTING COMPUTER CODE IS USED IN PARAMETRIC STUDY OF THE SAME EXAMPLE DESIGN CASE, NAMELY, A SIMPLE SOLAR SPACE HEATING INSTALLATION. COMPARISON OF THE THREE METHODS, BASED ON CALCULATIONS INVOLVING THREE WIDELY SPACED GREEK CITIES, SHOWS A MAXIMUM DIFFERENCE OF LESS THAN 6% IN THE PREDICTION OF THE ANNUAL SOLAR FRACTION.","abstract_has_math":false,"creators":["Παλυβός, Ιωάννης"],"institution":"National Technical University of Athens (NTUA)","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1991,"date_issued":"1991","date_published":"1991","updated_at":"2026-11-18T20:21:05Z","subjects":["ΓΕΝΙΚΕΥΜΕΝΟ ΔΙΑΓΡΑΜΜΑ","Διαστατική ανάλυση","ΕΜΠΕΙΡΙΚΕΣ ΣΥΣΧΕΤΙΣΕΙΣ","Επίπεδος ηλιακός συλλέκτης","Ηλιακή θέρμανση χώρων","ΗΛΙΑΚΟ ΚΛΑΣΜΑ","Μετεωρολογικά δεδομένα","ΠΑΡΑΜΕΤΡΙΚΗ ΜΕΛΕΤΗ","Προσομοιώσεις","ΣΤΡΩΜΑΤΟΠΟΙΗΜΕΝΗ ΔΕΞΑΜΕΝΗ ΑΠΟΘΗΚΕΥΣΗΣ","Dimensional analysis","EMPIRICAL CORRELATION","FLAT-PLATE SOLAR COLLECTOR","GENERALIZED PLOT","METEOROLOGICAL DATA","PARAMETRIC STUDY","Simulations","SOLAR FRACTION","SOLAR SPACE HEATING","STRATIFIED STORAGE TANK","Natural Sciences","Computer and Information Sciences","Engineering and Technology","Mechanical Engineering","Φυσικές Επιστήμες","Επιστήμη Ηλεκτρονικών Υπολογιστών και Πληροφορική","Επιστήμες Μηχανικού και Τεχνολογία","Επιστήμη Μηχανολόγου Μηχανικού"],"languages":["gre"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/1922"],"render_values":[{"text":"10.12681/eadd/1922","href":"https://doi.org/10.12681/eadd/1922","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10442/hedi/1922","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/10442/hedi/1922","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://phdtheses.ekt.gr/eadd_oai/request?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3A10442%2F1922","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Παλυβός, Ιωάννης"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1991"]},{"key":"dc:publisher","label":"Institution","values":["National Technical University of Athens (NTUA)","Εθνικό Μετσόβιο Πολυτεχνείο (ΕΜΠ)"]},{"key":"dc:type","label":"Dc Type","values":["PhD Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["ΓΕΝΙΚΕΥΜΕΝΟ ΔΙΑΓΡΑΜΜΑ","Διαστατική ανάλυση","ΕΜΠΕΙΡΙΚΕΣ ΣΥΣΧΕΤΙΣΕΙΣ","Επίπεδος ηλιακός συλλέκτης","Ηλιακή θέρμανση χώρων","ΗΛΙΑΚΟ ΚΛΑΣΜΑ","Μετεωρολογικά δεδομένα","ΠΑΡΑΜΕΤΡΙΚΗ ΜΕΛΕΤΗ","Προσομοιώσεις","ΣΤΡΩΜΑΤΟΠΟΙΗΜΕΝΗ ΔΕΞΑΜΕΝΗ ΑΠΟΘΗΚΕΥΣΗΣ","Dimensional analysis","EMPIRICAL CORRELATION","FLAT-PLATE SOLAR COLLECTOR","GENERALIZED PLOT","METEOROLOGICAL DATA","PARAMETRIC STUDY","Simulations","SOLAR FRACTION","SOLAR SPACE HEATING","STRATIFIED STORAGE TANK","Natural Sciences","Computer and Information Sciences","Engineering and Technology","Mechanical Engineering","Φυσικές Επιστήμες","Επιστήμη Ηλεκτρονικών Υπολογιστών και Πληροφορική","Επιστήμες Μηχανικού και Τεχνολογία","Επιστήμη Μηχανολόγου Μηχανικού"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["gre"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/1922","http://hdl.handle.net/10442/hedi/1922"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["METHODS OF SOLAR HEATING DESIGN WHICH VARY THE DESCRIPTION LEVEL ARE DEVELOPED AND COMPARED. INCLUDE A DETAILED SIMULATION, A SIMPLIFIED VERSION WHICH UTILIZES THE RELEVANT THERMAL NETWORK, AND AN EMPIRICAL SIGN TOOL BASED ON DIMENSIONALANALYSIS. IN EACH CASE, THE RESULTING COMPUTER CODE IS USED IN PARAMETRIC STUDY OF THE SAME EXAMPLE DESIGN CASE, NAMELY, A SIMPLE SOLAR SPACE HEATING INSTALLATION. COMPARISON OF THE THREE METHODS, BASED ON CALCULATIONS INVOLVING THREE WIDELY SPACED GREEK CITIES, SHOWS A MAXIMUM DIFFERENCE OF LESS THAN 6% IN THE PREDICTION OF THE ANNUAL SOLAR FRACTION.","ΜΕΘΟΔΟΙ ΣΧΕΔΙΑΣΜΟΥ ΗΛΙΑΚΩΝ ΣΥΣΤΗΜΑΤΩΝ ΘΕΡΜΑΝΣΗΣ ΟΙ ΟΠΟΙΕΣ ΔΙΑΦΕΡΟΥΝ ΣΤΟ ΕΠΙΠΕΔΟΠΕΡΙΓΡΑΦΗΣ ΑΝΑΠΤΥΣΣΟΝΤΑΙ ΚΑΙ ΣΥΓΚΡΙΝΟΝΤΑΙ. ΠΡΟΚΕΙΤΑΙ ΓΙΑ ΜΙΑ ΛΕΠΤΟΜΕΡΗ ΠΡΟΣΟΜΟΙΩΣΗ, ΜΙΑ ΑΠΛΟΥΣΤΕΡΗ ΠΑΡΑΛΛΑΓΗ ΠΟΥ ΒΑΣΙΖΕΤΑΙ ΣΤΟ ΘΕΡΜΙΚΟ ΔΙΚΤΥΟ ΚΑΙ ΤΟ ΗΛΕΚΤΡΙΚΟ ΤΟΥ ΑΝΑΛΟΓΟ ΚΑΙ, ΤΕΛΟΣ, ΜΙΑ ΕΜΠΕΙΡΙΚΗ ΜΕΘΟΔΟ ΒΑΣΙΣΜΕΝΗ ΣΤΗ ΔΙΑΣΤΑΤΙΚΗ ΑΝΑΛΥΣΗ. ΣΕ ΟΛΕΣ ΤΙΣ ΠΕΡΙΠΤΩΣΕΙΣ, Ο ΚΩΔΙΚΑΣ Η/Υ ΧΡΗΣΙΜΟΠΟΙΕΙΤΑΙ ΣΕ ΠΑΡΑΜΕΤΡΙΚΗ ΜΕΛΕΤΗΤΟΥ ΙΔΙΟΥ ΠΡΟΤΥΠΟΥ ΣΥΣΤΗΜΑΤΟΣ-ΠΑΡΑΔΕΙΓΜΑΤΟΣ, ΔΗΛΑΔΗ ΕΝΟΣ ΑΠΛΟΥ ΣΥΣΤΗΜΑΤΟΣ ΗΛΙΑΚΗΣ ΘΕΡΜΑΝΣΗΣ ΧΩΡΩΝ. ΣΥΓΚΡΙΣΗ ΤΩΝ ΤΡΙΩΝ ΜΕΘΟΔΩΝ, ΜΕ ΒΑΣΗ ΥΠΟΛΟΓΙΣΜΟΥΣ ΓΙΑ ΤΡΕΙΣΠΟΛΕΙΣ ΤΟΥ ΕΥΡΥΤΕΡΟΥ ΕΛΛΑΔΙΚΟΥ ΧΩΡΟΥ, ΔΕΙΧΝΕΙ ΜΕΓΙΣΤΗ ΔΙΑΦΟΡΑ ΜΙΚΡΟΤΕΡΗ ΤΟΥ 6%ΣΤΟ ΠΡΟΒΛΕΠΟΜΕΝΟ ΕΤΗΣΙΟ ΗΛΙΑΚΟ ΚΛΑΣΜΑ."]},{"key":"dc:title","label":"Title","values":["Ο Η/Υ ΣΤΟ ΣΧΕΔΙΑΣΜΟ ΗΛΙΑΚΩΝ ΣΥΣΤΗΜΑΤΩΝ. ΕΠΙΠΕΔΑ ΠΕΡΙΓΡΑΦΗΣ ΚΑΙ ΟΡΙΑ ΑΞΙΟΠΙΣΤΙΑΣ","THE ELECTRONIC COMPUTER IN THE DESIGN OF SOLAR SYSTEMS. DESCRIPTION LEVELS AND RELIABILITY LIMITS"]}]}],"canonical_facts":{"dc:creator":["Παλυβός, Ιωάννης"],"dc:date":["1991"],"dc:description":["METHODS OF SOLAR HEATING DESIGN WHICH VARY THE DESCRIPTION LEVEL ARE DEVELOPED AND COMPARED. INCLUDE A DETAILED SIMULATION, A SIMPLIFIED VERSION WHICH UTILIZES THE RELEVANT THERMAL NETWORK, AND AN EMPIRICAL SIGN TOOL BASED ON DIMENSIONALANALYSIS. IN EACH CASE, THE RESULTING COMPUTER CODE IS USED IN PARAMETRIC STUDY OF THE SAME EXAMPLE DESIGN CASE, NAMELY, A SIMPLE SOLAR SPACE HEATING INSTALLATION. COMPARISON OF THE THREE METHODS, BASED ON CALCULATIONS INVOLVING THREE WIDELY SPACED GREEK CITIES, SHOWS A MAXIMUM DIFFERENCE OF LESS THAN 6% IN THE PREDICTION OF THE ANNUAL SOLAR FRACTION.","ΜΕΘΟΔΟΙ ΣΧΕΔΙΑΣΜΟΥ ΗΛΙΑΚΩΝ ΣΥΣΤΗΜΑΤΩΝ ΘΕΡΜΑΝΣΗΣ ΟΙ ΟΠΟΙΕΣ ΔΙΑΦΕΡΟΥΝ ΣΤΟ ΕΠΙΠΕΔΟΠΕΡΙΓΡΑΦΗΣ ΑΝΑΠΤΥΣΣΟΝΤΑΙ ΚΑΙ ΣΥΓΚΡΙΝΟΝΤΑΙ. ΠΡΟΚΕΙΤΑΙ ΓΙΑ ΜΙΑ ΛΕΠΤΟΜΕΡΗ ΠΡΟΣΟΜΟΙΩΣΗ, ΜΙΑ ΑΠΛΟΥΣΤΕΡΗ ΠΑΡΑΛΛΑΓΗ ΠΟΥ ΒΑΣΙΖΕΤΑΙ ΣΤΟ ΘΕΡΜΙΚΟ ΔΙΚΤΥΟ ΚΑΙ ΤΟ ΗΛΕΚΤΡΙΚΟ ΤΟΥ ΑΝΑΛΟΓΟ ΚΑΙ, ΤΕΛΟΣ, ΜΙΑ ΕΜΠΕΙΡΙΚΗ ΜΕΘΟΔΟ ΒΑΣΙΣΜΕΝΗ ΣΤΗ ΔΙΑΣΤΑΤΙΚΗ ΑΝΑΛΥΣΗ. ΣΕ ΟΛΕΣ ΤΙΣ ΠΕΡΙΠΤΩΣΕΙΣ, Ο ΚΩΔΙΚΑΣ Η/Υ ΧΡΗΣΙΜΟΠΟΙΕΙΤΑΙ ΣΕ ΠΑΡΑΜΕΤΡΙΚΗ ΜΕΛΕΤΗΤΟΥ ΙΔΙΟΥ ΠΡΟΤΥΠΟΥ ΣΥΣΤΗΜΑΤΟΣ-ΠΑΡΑΔΕΙΓΜΑΤΟΣ, ΔΗΛΑΔΗ ΕΝΟΣ ΑΠΛΟΥ ΣΥΣΤΗΜΑΤΟΣ ΗΛΙΑΚΗΣ ΘΕΡΜΑΝΣΗΣ ΧΩΡΩΝ. ΣΥΓΚΡΙΣΗ ΤΩΝ ΤΡΙΩΝ ΜΕΘΟΔΩΝ, ΜΕ ΒΑΣΗ ΥΠΟΛΟΓΙΣΜΟΥΣ ΓΙΑ ΤΡΕΙΣΠΟΛΕΙΣ ΤΟΥ ΕΥΡΥΤΕΡΟΥ ΕΛΛΑΔΙΚΟΥ ΧΩΡΟΥ, ΔΕΙΧΝΕΙ ΜΕΓΙΣΤΗ ΔΙΑΦΟΡΑ ΜΙΚΡΟΤΕΡΗ ΤΟΥ 6%ΣΤΟ ΠΡΟΒΛΕΠΟΜΕΝΟ ΕΤΗΣΙΟ ΗΛΙΑΚΟ ΚΛΑΣΜΑ."],"dc:identifier":["10.12681/eadd/1922","http://hdl.handle.net/10442/hedi/1922"],"dc:language":["gre"],"dc:publisher":["National Technical University of Athens (NTUA)","Εθνικό Μετσόβιο Πολυτεχνείο (ΕΜΠ)"],"dc:subject":["ΓΕΝΙΚΕΥΜΕΝΟ ΔΙΑΓΡΑΜΜΑ","Διαστατική ανάλυση","ΕΜΠΕΙΡΙΚΕΣ ΣΥΣΧΕΤΙΣΕΙΣ","Επίπεδος ηλιακός συλλέκτης","Ηλιακή θέρμανση χώρων","ΗΛΙΑΚΟ ΚΛΑΣΜΑ","Μετεωρολογικά δεδομένα","ΠΑΡΑΜΕΤΡΙΚΗ ΜΕΛΕΤΗ","Προσομοιώσεις","ΣΤΡΩΜΑΤΟΠΟΙΗΜΕΝΗ ΔΕΞΑΜΕΝΗ ΑΠΟΘΗΚΕΥΣΗΣ","Dimensional analysis","EMPIRICAL CORRELATION","FLAT-PLATE SOLAR COLLECTOR","GENERALIZED PLOT","METEOROLOGICAL DATA","PARAMETRIC STUDY","Simulations","SOLAR FRACTION","SOLAR SPACE HEATING","STRATIFIED STORAGE TANK","Natural Sciences","Computer and Information Sciences","Engineering and Technology","Mechanical Engineering","Φυσικές Επιστήμες","Επιστήμη Ηλεκτρονικών Υπολογιστών και Πληροφορική","Επιστήμες Μηχανικού και Τεχνολογία","Επιστήμη Μηχανολόγου Μηχανικού"],"dc:title":["Ο Η/Υ ΣΤΟ ΣΧΕΔΙΑΣΜΟ ΗΛΙΑΚΩΝ ΣΥΣΤΗΜΑΤΩΝ. ΕΠΙΠΕΔΑ ΠΕΡΙΓΡΑΦΗΣ ΚΑΙ ΟΡΙΑ ΑΞΙΟΠΙΣΤΙΑΣ","THE ELECTRONIC COMPUTER IN THE DESIGN OF SOLAR SYSTEMS. DESCRIPTION LEVELS AND RELIABILITY LIMITS"],"dc:type":["PhD Thesis"]},"updated_at":"2026-11-18T20:21:05Z"}