{"id":{"repo_id":"greece","oai_identifier":"oai:10442/19384"},"canonical_url":"https://search.ndltd.org/etd/greece/oai:10442/19384","repository":{"repo_id":"greece","name":"Greek National Archive of PhD Theses","base_url":"https://phdtheses.ekt.gr/eadd_oai/request"},"display":{"title":"Φθορά κινητού ένθετου πολυαιθυλενίου σε ολική αρθροπλαστική γόνατος: κλινική και πειραματική μελέτη","abstract":"We studied the wear of the Rotaglide mobile polyethylene bearings following experimental and clinical use. At 5 million cycles and with the same simulation system, the mobile bearings exhibited up to four times less wear than the fixed IB inserts, which were tested at the same time. We also studied 26 retrieved Rotaglide inserts with 8 years (3 months to 15.6 years) mean period of use. The 7mm and 9.5 mm of thickness inserts, showed moderate to severe wear after 9.5 years. In 51-85% of the upper surface, delamination dominates, but plastic deformation and pitting to a much lesser extend are also present. Little wear of burnishing type and abrasions, develop after 5.5 years mainly in the posterior condyles and in the thin inserts is accompanied by fracture and loss of material. In all bearings, regardless of thickness there is no significant backside wear. 18% of the backside surface had no wear, 42% showed some abrasions and scattered areas of burnishing and the remaining 40% is dominated by pitting inside areas of burnishing.","abstract_html":"We studied the wear of the Rotaglide mobile polyethylene bearings following experimental and clinical use. At 5 million cycles and with the same simulation system, the mobile bearings exhibited up to four times less wear than the fixed IB inserts, which were tested at the same time. We also studied 26 retrieved Rotaglide inserts with 8 years (3 months to 15.6 years) mean period of use. The 7mm and 9.5 mm of thickness inserts, showed moderate to severe wear after 9.5 years. In 51-85% of the upper surface, delamination dominates, but plastic deformation and pitting to a much lesser extend are also present. Little wear of burnishing type and abrasions, develop after 5.5 years mainly in the posterior condyles and in the thin inserts is accompanied by fracture and loss of material. In all bearings, regardless of thickness there is no significant backside wear. 18% of the backside surface had no wear, 42% showed some abrasions and scattered areas of burnishing and the remaining 40% is dominated by pitting inside areas of burnishing.","abstract_has_math":false,"creators":["Nicolaides, A.","Νικολαΐδης, Αναστάσιος"],"institution":"Aristotle University Of Thessaloniki (AUTH)","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008","date_published":"2008","updated_at":"2026-11-18T20:38:47Z","subjects":["Κινητό ένθετο πολυαιθυλενίου","Φθορά","Ολική αρθροπλαστική γόνατος","Οπίσθια επιφάνεια","Ανώτερη αρθρική επιφάνεια","Rotaglide","Wear","Ιατρική και Επιστήμες Υγείας","Κλινική Ιατρική","Medical and Health Sciences","Clinical Medicine"],"languages":["gre"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/19384"],"render_values":[{"text":"10.12681/eadd/19384","href":"https://doi.org/10.12681/eadd/19384","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10442/hedi/19384","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/10442/hedi/19384","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://phdtheses.ekt.gr/eadd_oai/request?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3A10442%2F19384","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Nicolaides, A.","Νικολαΐδης, Αναστάσιος"]},{"key":"dc:creator.fathername","label":"Dc Creator Fathername","values":["Panagiotis"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2008"]},{"key":"dc:publisher","label":"Institution","values":["Aristotle University Of Thessaloniki (AUTH)","Αριστοτέλειο Πανεπιστήμιο Θεσσαλονίκης (ΑΠΘ)"]},{"key":"dc:type","label":"Dc Type","values":["PhD Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Κινητό ένθετο πολυαιθυλενίου","Φθορά","Ολική αρθροπλαστική γόνατος","Οπίσθια επιφάνεια","Ανώτερη αρθρική επιφάνεια","Rotaglide","Wear","Ιατρική και Επιστήμες Υγείας","Κλινική Ιατρική","Medical and Health Sciences","Clinical Medicine"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["gre"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/19384","http://hdl.handle.net/10442/hedi/19384"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["We studied the wear of the Rotaglide mobile polyethylene bearings following experimental and clinical use. At 5 million cycles and with the same simulation system, the mobile bearings exhibited up to four times less wear than the fixed IB inserts, which were tested at the same time. We also studied 26 retrieved Rotaglide inserts with 8 years (3 months to 15.6 years) mean period of use. The 7mm and 9.5 mm of thickness inserts, showed moderate to severe wear after 9.5 years. In 51-85% of the upper surface, delamination dominates, but plastic deformation and pitting to a much lesser extend are also present. Little wear of burnishing type and abrasions, develop after 5.5 years mainly in the posterior condyles and in the thin inserts is accompanied by fracture and loss of material. In all bearings, regardless of thickness there is no significant backside wear. 18% of the backside surface had no wear, 42% showed some abrasions and scattered areas of burnishing and the remaining 40% is dominated by pitting inside areas of burnishing.","Μελετήθηκε η φθορά μετά από πειραματική και κλινική χρήση κινητών ενθέτων πολυαιθυλενίου Rotaglide. Στους 5 μεγάκυκλους και στο ίδιο σύστημα εξομοίωσης της κίνησης, τα κινητά ένθετα εμφάνισαν έως και τέσσερις φορές μικρότερη φθορά απ' ότι τα σταθερά ένθετα της ενδοπρόθεσης ΙΒ. Μελετήθηκαν επίσης 26 κινητά ένθετα Rotaglide, που αφαιρέθηκαν από ασθενείς μετά από μέση διάρκεια λειτουργίας in vivo 8 ετών (3 μήνες - 15.6 έτη). Μέτρια και σημαντική φθορά της ανώτερης αρθρικής επιφάνειας παρατηρείται σε ένθετα με διάρκεια λειτουργίας πάνω από 9.5 έτη και αφορά στη συντριπτική τους πλειοψηφία ένθετα πάχους 7mm και 9.5mm. Στο 51%-85% της συνολικής ανώτερης αρθρικής επιφάνειας αυτών των ενθέτων, η μορφή της φθοράς είναι κυρίως τύπου αποφυλλιδοποίησης (delamination) και σε μικρότερο ποσοστό παραμορφωτική ή δίκην κρατήρα (pitting). Μικρή φθορά εμφανίζεται μετά τα 5.5 έτη και είναι κυρίως τύπου εκδορών και στιλβωματική. H φθορά εντοπίζεται κυρίως στους οπίσθιους κονδύλους, ενώ στα λεπτά ένθετα συνυπάρχει θραύση κάταγμα με απώλεια υλικού. Σε όλα τα ένθετα, ανεξαρτήτως πάχους, δεν υπάρχει σημαντική φθορά στην οπίσθια επιφάνεια (backside wear), εκτός από τις περιοχές εκείνες που συνυπάρχει θραύση του οπισθίου κονδύλου. Στο 18% της συνολικής οπίσθιας επιφάνειας δεν παρατηρήθηκε καθόλου φθορά, στο 42% επικρατούν οι εκδορές με κατά τόπους περιοχές στιλβωμάτωσης, ενώ στο υπόλοιπο 40% επικρατεί ο συνδυασμός φθοράς τύπου «δίκην κρατήρα» μέσα σε περιοχές στιλβωμάτωσης."]},{"key":"dc:title","label":"Title","values":["Φθορά κινητού ένθετου πολυαιθυλενίου σε ολική αρθροπλαστική γόνατος: κλινική και πειραματική μελέτη","Wear of polyethylene mobile inserts in total knee arthroplasty: clinical and experimental study"]}]}],"canonical_facts":{"dc:creator":["Nicolaides, A.","Νικολαΐδης, Αναστάσιος"],"dc:creator.fathername":["Panagiotis"],"dc:date":["2008"],"dc:description":["We studied the wear of the Rotaglide mobile polyethylene bearings following experimental and clinical use. At 5 million cycles and with the same simulation system, the mobile bearings exhibited up to four times less wear than the fixed IB inserts, which were tested at the same time. We also studied 26 retrieved Rotaglide inserts with 8 years (3 months to 15.6 years) mean period of use. The 7mm and 9.5 mm of thickness inserts, showed moderate to severe wear after 9.5 years. In 51-85% of the upper surface, delamination dominates, but plastic deformation and pitting to a much lesser extend are also present. Little wear of burnishing type and abrasions, develop after 5.5 years mainly in the posterior condyles and in the thin inserts is accompanied by fracture and loss of material. In all bearings, regardless of thickness there is no significant backside wear. 18% of the backside surface had no wear, 42% showed some abrasions and scattered areas of burnishing and the remaining 40% is dominated by pitting inside areas of burnishing.","Μελετήθηκε η φθορά μετά από πειραματική και κλινική χρήση κινητών ενθέτων πολυαιθυλενίου Rotaglide. Στους 5 μεγάκυκλους και στο ίδιο σύστημα εξομοίωσης της κίνησης, τα κινητά ένθετα εμφάνισαν έως και τέσσερις φορές μικρότερη φθορά απ' ότι τα σταθερά ένθετα της ενδοπρόθεσης ΙΒ. Μελετήθηκαν επίσης 26 κινητά ένθετα Rotaglide, που αφαιρέθηκαν από ασθενείς μετά από μέση διάρκεια λειτουργίας in vivo 8 ετών (3 μήνες - 15.6 έτη). Μέτρια και σημαντική φθορά της ανώτερης αρθρικής επιφάνειας παρατηρείται σε ένθετα με διάρκεια λειτουργίας πάνω από 9.5 έτη και αφορά στη συντριπτική τους πλειοψηφία ένθετα πάχους 7mm και 9.5mm. Στο 51%-85% της συνολικής ανώτερης αρθρικής επιφάνειας αυτών των ενθέτων, η μορφή της φθοράς είναι κυρίως τύπου αποφυλλιδοποίησης (delamination) και σε μικρότερο ποσοστό παραμορφωτική ή δίκην κρατήρα (pitting). Μικρή φθορά εμφανίζεται μετά τα 5.5 έτη και είναι κυρίως τύπου εκδορών και στιλβωματική. H φθορά εντοπίζεται κυρίως στους οπίσθιους κονδύλους, ενώ στα λεπτά ένθετα συνυπάρχει θραύση κάταγμα με απώλεια υλικού. Σε όλα τα ένθετα, ανεξαρτήτως πάχους, δεν υπάρχει σημαντική φθορά στην οπίσθια επιφάνεια (backside wear), εκτός από τις περιοχές εκείνες που συνυπάρχει θραύση του οπισθίου κονδύλου. Στο 18% της συνολικής οπίσθιας επιφάνειας δεν παρατηρήθηκε καθόλου φθορά, στο 42% επικρατούν οι εκδορές με κατά τόπους περιοχές στιλβωμάτωσης, ενώ στο υπόλοιπο 40% επικρατεί ο συνδυασμός φθοράς τύπου «δίκην κρατήρα» μέσα σε περιοχές στιλβωμάτωσης."],"dc:identifier":["10.12681/eadd/19384","http://hdl.handle.net/10442/hedi/19384"],"dc:language":["gre"],"dc:publisher":["Aristotle University Of Thessaloniki (AUTH)","Αριστοτέλειο Πανεπιστήμιο Θεσσαλονίκης (ΑΠΘ)"],"dc:subject":["Κινητό ένθετο πολυαιθυλενίου","Φθορά","Ολική αρθροπλαστική γόνατος","Οπίσθια επιφάνεια","Ανώτερη αρθρική επιφάνεια","Rotaglide","Wear","Ιατρική και Επιστήμες Υγείας","Κλινική Ιατρική","Medical and Health Sciences","Clinical Medicine"],"dc:title":["Φθορά κινητού ένθετου πολυαιθυλενίου σε ολική αρθροπλαστική γόνατος: κλινική και πειραματική μελέτη","Wear of polyethylene mobile inserts in total knee arthroplasty: clinical and experimental study"],"dc:type":["PhD Thesis"]},"updated_at":"2026-11-18T20:38:47Z"}