{"id":{"repo_id":"greece","oai_identifier":"oai:10442/1946"},"canonical_url":"https://search.ndltd.org/etd/greece/oai:10442/1946","repository":{"repo_id":"greece","name":"Greek National Archive of PhD Theses","base_url":"https://phdtheses.ekt.gr/eadd_oai/request"},"display":{"title":"ΠΡΟΣΕΓΓΙΣΤΙΚΕΣ ΜΕΘΟΔΟΙ ΜΕΛΕΤΗΣ ΚΛΕΙΣΤΟΥ ΣΥΣΤΗΜΑΤΟΣ DC-AC ΜΕΤΑΤΡΟΠΕΑ ΓΙΑ ΤΟΝ ΕΛΕΓΧΟ ΡΕΥΜΑΤΟΣ ΣΕ ΣΥΝΘΕΤΑ ΦΟΡΤΙΑ","abstract":"A STUDY OF A CLOSED-LOOP DC-AC INVERTER SYSTEM IS PRESENTED. THE INVERTER IS CONTROLLED BY A RECTANGULAR HYSTERESIS LOOP, FEEDING A COMPOUND LOAD WITH PULSE WIDTH MODULATED (PWM) POWER PULSES BY A REFERENCE VOLTAGE. BY AN ANALYTICAL METHOD THE RELATIONSHIP CONNECTING THE OUTPUT PULSE WIDTH TO REFERENCE VOLTAGE WAS CALCULATED. THERE WAS ALSO AN APPROXIMATIVE METHOD DEVELOPED, GIVING SIMPLER RELATION. BY MEANS OF A FILTER IN SERIES TO RL LOAD, OUTPUT PULSE FREQUENCY REDUCTION, SIMULTANEOUSLY REDUCING ERROR VOLTAGE WAS ACCOMPLISHED. THERE IS ALSO A METHOD CONCERNING THE INVERTER'S FILTER DESIGNING WHICH CAN ALSO BE APPLIED TO VARIABLE RESISTANCE LOADS, SUCH AS AC MOTORS.","abstract_html":"A STUDY OF A CLOSED-LOOP DC-AC INVERTER SYSTEM IS PRESENTED. THE INVERTER IS CONTROLLED BY A RECTANGULAR HYSTERESIS LOOP, FEEDING A COMPOUND LOAD WITH PULSE WIDTH MODULATED (PWM) POWER PULSES BY A REFERENCE VOLTAGE. BY AN ANALYTICAL METHOD THE RELATIONSHIP CONNECTING THE OUTPUT PULSE WIDTH TO REFERENCE VOLTAGE WAS CALCULATED. THERE WAS ALSO AN APPROXIMATIVE METHOD DEVELOPED, GIVING SIMPLER RELATION. BY MEANS OF A FILTER IN SERIES TO RL LOAD, OUTPUT PULSE FREQUENCY REDUCTION, SIMULTANEOUSLY REDUCING ERROR VOLTAGE WAS ACCOMPLISHED. THERE IS ALSO A METHOD CONCERNING THE INVERTER&#x27;S FILTER DESIGNING WHICH CAN ALSO BE APPLIED TO VARIABLE RESISTANCE LOADS, SUCH AS AC MOTORS.","abstract_has_math":false,"creators":["Κοσματόπουλος, Κωνσταντίνος","Kosmatopoulos, Konstantinos"],"institution":"Αριστοτέλειο Πανεπιστήμιο Θεσσαλονίκης (ΑΠΘ)","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1991,"date_issued":"1991","date_published":"1991","updated_at":"2026-11-18T20:21:16Z","subjects":["ASYNCHROMOUS DELTA MODULATION","CONTROLLERS WITH HYSTERESIS","Current control","DESCRIBING FUNCTION","Inverter","LIMIT CYCLES","ΑΣΥΓΧΡΟΝΗ Δ-ΔΙΑΜΟΡΦΩΣΗ","ΕΛΕΓΚΤΕΣ ΜΕ ΥΣΤΕΡΗΣΗ","Έλεγχος ρεύματος","Εναλλακτής","ΟΡΙΑΚΟΙ ΚΥΚΛΟΙ","ΠΕΡΙΓΡΑΦΙΚΗ ΣΥΝΑΡΤΗΣΗ","Φυσικές Επιστήμες","Natural Sciences","Φυσική","Physical Sciences"],"languages":["gre"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/1946"],"render_values":[{"text":"10.12681/eadd/1946","href":"https://doi.org/10.12681/eadd/1946","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10442/hedi/1946","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/10442/hedi/1946","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://phdtheses.ekt.gr/eadd_oai/request?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3A10442%2F1946","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Κοσματόπουλος, Κωνσταντίνος","Kosmatopoulos, Konstantinos"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1991"]},{"key":"dc:publisher","label":"Institution","values":["Αριστοτέλειο Πανεπιστήμιο Θεσσαλονίκης (ΑΠΘ)","Aristotle University Of Thessaloniki (AUTH)"]},{"key":"dc:type","label":"Dc Type","values":["PhD Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["ASYNCHROMOUS DELTA MODULATION","CONTROLLERS WITH HYSTERESIS","Current control","DESCRIBING FUNCTION","Inverter","LIMIT CYCLES","ΑΣΥΓΧΡΟΝΗ Δ-ΔΙΑΜΟΡΦΩΣΗ","ΕΛΕΓΚΤΕΣ ΜΕ ΥΣΤΕΡΗΣΗ","Έλεγχος ρεύματος","Εναλλακτής","ΟΡΙΑΚΟΙ ΚΥΚΛΟΙ","ΠΕΡΙΓΡΑΦΙΚΗ ΣΥΝΑΡΤΗΣΗ","Φυσικές Επιστήμες","Natural Sciences","Φυσική","Physical Sciences"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["gre"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/1946","http://hdl.handle.net/10442/hedi/1946"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A STUDY OF A CLOSED-LOOP DC-AC INVERTER SYSTEM IS PRESENTED. THE INVERTER IS CONTROLLED BY A RECTANGULAR HYSTERESIS LOOP, FEEDING A COMPOUND LOAD WITH PULSE WIDTH MODULATED (PWM) POWER PULSES BY A REFERENCE VOLTAGE. BY AN ANALYTICAL METHOD THE RELATIONSHIP CONNECTING THE OUTPUT PULSE WIDTH TO REFERENCE VOLTAGE WAS CALCULATED. THERE WAS ALSO AN APPROXIMATIVE METHOD DEVELOPED, GIVING SIMPLER RELATION. BY MEANS OF A FILTER IN SERIES TO RL LOAD, OUTPUT PULSE FREQUENCY REDUCTION, SIMULTANEOUSLY REDUCING ERROR VOLTAGE WAS ACCOMPLISHED. THERE IS ALSO A METHOD CONCERNING THE INVERTER'S FILTER DESIGNING WHICH CAN ALSO BE APPLIED TO VARIABLE RESISTANCE LOADS, SUCH AS AC MOTORS.","ΣΤΗ ΔΙΑΤΡΙΒΗ ΑΥΤΗ, ΓΙΝΕΤΑΙ ΜΕΛΕΤΗ ΕΝΟΣ ΚΛΕΙΣΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΜΕΤΑΤΡΟΠΕΑ DC-AC Ο ΟΠΟΙΟΣ ΕΛΕΓΧΕΤΑΙ ΑΠΟ ΕΝΑ ΟΘΡΟΓΩΝΙΟ ΒΡΟΧΟ ΥΣΤΕΡΗΣΗΣ ΚΑΙ ΤΡΟΦΟΔΟΤΕΙ ΕΝΑ ΣΥΝΘΕΤΟ ΦΟΡΤΙΟ ΜΕ ΠΑΛΜΟΥΣ ΙΣΧΥΟΣ, ΔΙΑΜΟΡΦΩΜΕΝΟΥΣ ΚΑΤΑ ΕΥΡΟΣ (PWM) ΑΠΟ ΜΙΑ ΤΑΣΗ ΑΝΑΦΟΡΑΣ. ΥΠΟΛΟΓΙΣΤΗΚΕ ΜΕ ΑΝΑΛΥΤΙΚΗ ΜΕΘΟΔΟ, Η ΣΧΕΣΗ ΠΟΥ ΣΥΝΔΕΕΙ ΤΟ ΕΥΡΟΣ ΤΩΝ ΠΑΛΜΩΝ ΕΞΟΔΟΥ ΜΕ ΤΗΝ ΤΑΣΗ ΑΝΑΦΟΡΑΣ. ΕΠΙΣΗΣ ΑΝΑΠΤΥΧΘΗΚΕ ΜΙΑ ΠΡΟΣΕΓΓΙΣΤΙΚΗ ΜΕΘΟΔΟΣ ΠΟΥ ΕΔΩΣΕ ΑΠΛΟΥΣΤΕΡΕΣ ΣΧΕΣΕΙΣ. ΜΕ ΤΗ ΧΡΗΣΗ ΕΝΟΣ ΦΙΛΤΡΟΥ ΣΕ ΣΕΙΡΑ ΜΕ ΤΟ RL ΦΟΡΤΙΟ, ΕΠΕΤΕΥΧΘΗ ΕΛΑΤΤΩΣΗ ΤΗΣ ΣΥΧΝΟΤΗΤΑΣ ΤΩΝ ΠΑΛΜΩΝ ΕΞΟΔΟΥ, ΜΕΙΩΝΟΝΤΑΣ ΣΥΓΧΡΟΝΩΣ ΤΗΝ ΤΑΣΗ ΣΦΑΛΜΑΤΟΣ. ΕΠΙΣΗΣ ΜΕΛΕΤΑΤΑΙ ΜΙΑ ΜΕΘΟΔΟΣ ΓΙΑ ΤΟΝ ΣΧΕΔΙΑΣΜΟ ΤΟΥ ΦΙΛΤΡΟΥ ΤΟΥ ΕΝΑΛΛΑΚΤΗ, Η ΟΠΟΙΑ ΕΠΕΚΤΕΙΝΕΤΑΙ ΚΑΙ ΣΕ ΦΟΡΤΙΑ ΜΕ ΜΕΤΑΒΛΗΤΗ ΑΝΤΙΣΤΑΣΗ, ΟΠΩΣ ΕΙΝΑΙ ΟI AC ΚΙΝΗΤΗΡΕΣ."]},{"key":"dc:title","label":"Title","values":["ΠΡΟΣΕΓΓΙΣΤΙΚΕΣ ΜΕΘΟΔΟΙ ΜΕΛΕΤΗΣ ΚΛΕΙΣΤΟΥ ΣΥΣΤΗΜΑΤΟΣ DC-AC ΜΕΤΑΤΡΟΠΕΑ ΓΙΑ ΤΟΝ ΕΛΕΓΧΟ ΡΕΥΜΑΤΟΣ ΣΕ ΣΥΝΘΕΤΑ ΦΟΡΤΙΑ","APPROXIMATIVE METHODS OF A CLOSED-LOOP DC-AC INVERTER SYSTEM'S STUDY FOR CURRENT CONTROL IN COMPOUND LOADS"]}]}],"canonical_facts":{"dc:creator":["Κοσματόπουλος, Κωνσταντίνος","Kosmatopoulos, Konstantinos"],"dc:date":["1991"],"dc:description":["A STUDY OF A CLOSED-LOOP DC-AC INVERTER SYSTEM IS PRESENTED. THE INVERTER IS CONTROLLED BY A RECTANGULAR HYSTERESIS LOOP, FEEDING A COMPOUND LOAD WITH PULSE WIDTH MODULATED (PWM) POWER PULSES BY A REFERENCE VOLTAGE. BY AN ANALYTICAL METHOD THE RELATIONSHIP CONNECTING THE OUTPUT PULSE WIDTH TO REFERENCE VOLTAGE WAS CALCULATED. THERE WAS ALSO AN APPROXIMATIVE METHOD DEVELOPED, GIVING SIMPLER RELATION. BY MEANS OF A FILTER IN SERIES TO RL LOAD, OUTPUT PULSE FREQUENCY REDUCTION, SIMULTANEOUSLY REDUCING ERROR VOLTAGE WAS ACCOMPLISHED. THERE IS ALSO A METHOD CONCERNING THE INVERTER'S FILTER DESIGNING WHICH CAN ALSO BE APPLIED TO VARIABLE RESISTANCE LOADS, SUCH AS AC MOTORS.","ΣΤΗ ΔΙΑΤΡΙΒΗ ΑΥΤΗ, ΓΙΝΕΤΑΙ ΜΕΛΕΤΗ ΕΝΟΣ ΚΛΕΙΣΤΟΥ ΣΥΣΤΗΜΑΤΟΣ ΜΕΤΑΤΡΟΠΕΑ DC-AC Ο ΟΠΟΙΟΣ ΕΛΕΓΧΕΤΑΙ ΑΠΟ ΕΝΑ ΟΘΡΟΓΩΝΙΟ ΒΡΟΧΟ ΥΣΤΕΡΗΣΗΣ ΚΑΙ ΤΡΟΦΟΔΟΤΕΙ ΕΝΑ ΣΥΝΘΕΤΟ ΦΟΡΤΙΟ ΜΕ ΠΑΛΜΟΥΣ ΙΣΧΥΟΣ, ΔΙΑΜΟΡΦΩΜΕΝΟΥΣ ΚΑΤΑ ΕΥΡΟΣ (PWM) ΑΠΟ ΜΙΑ ΤΑΣΗ ΑΝΑΦΟΡΑΣ. ΥΠΟΛΟΓΙΣΤΗΚΕ ΜΕ ΑΝΑΛΥΤΙΚΗ ΜΕΘΟΔΟ, Η ΣΧΕΣΗ ΠΟΥ ΣΥΝΔΕΕΙ ΤΟ ΕΥΡΟΣ ΤΩΝ ΠΑΛΜΩΝ ΕΞΟΔΟΥ ΜΕ ΤΗΝ ΤΑΣΗ ΑΝΑΦΟΡΑΣ. ΕΠΙΣΗΣ ΑΝΑΠΤΥΧΘΗΚΕ ΜΙΑ ΠΡΟΣΕΓΓΙΣΤΙΚΗ ΜΕΘΟΔΟΣ ΠΟΥ ΕΔΩΣΕ ΑΠΛΟΥΣΤΕΡΕΣ ΣΧΕΣΕΙΣ. ΜΕ ΤΗ ΧΡΗΣΗ ΕΝΟΣ ΦΙΛΤΡΟΥ ΣΕ ΣΕΙΡΑ ΜΕ ΤΟ RL ΦΟΡΤΙΟ, ΕΠΕΤΕΥΧΘΗ ΕΛΑΤΤΩΣΗ ΤΗΣ ΣΥΧΝΟΤΗΤΑΣ ΤΩΝ ΠΑΛΜΩΝ ΕΞΟΔΟΥ, ΜΕΙΩΝΟΝΤΑΣ ΣΥΓΧΡΟΝΩΣ ΤΗΝ ΤΑΣΗ ΣΦΑΛΜΑΤΟΣ. ΕΠΙΣΗΣ ΜΕΛΕΤΑΤΑΙ ΜΙΑ ΜΕΘΟΔΟΣ ΓΙΑ ΤΟΝ ΣΧΕΔΙΑΣΜΟ ΤΟΥ ΦΙΛΤΡΟΥ ΤΟΥ ΕΝΑΛΛΑΚΤΗ, Η ΟΠΟΙΑ ΕΠΕΚΤΕΙΝΕΤΑΙ ΚΑΙ ΣΕ ΦΟΡΤΙΑ ΜΕ ΜΕΤΑΒΛΗΤΗ ΑΝΤΙΣΤΑΣΗ, ΟΠΩΣ ΕΙΝΑΙ ΟI AC ΚΙΝΗΤΗΡΕΣ."],"dc:identifier":["10.12681/eadd/1946","http://hdl.handle.net/10442/hedi/1946"],"dc:language":["gre"],"dc:publisher":["Αριστοτέλειο Πανεπιστήμιο Θεσσαλονίκης (ΑΠΘ)","Aristotle University Of Thessaloniki (AUTH)"],"dc:subject":["ASYNCHROMOUS DELTA MODULATION","CONTROLLERS WITH HYSTERESIS","Current control","DESCRIBING FUNCTION","Inverter","LIMIT CYCLES","ΑΣΥΓΧΡΟΝΗ Δ-ΔΙΑΜΟΡΦΩΣΗ","ΕΛΕΓΚΤΕΣ ΜΕ ΥΣΤΕΡΗΣΗ","Έλεγχος ρεύματος","Εναλλακτής","ΟΡΙΑΚΟΙ ΚΥΚΛΟΙ","ΠΕΡΙΓΡΑΦΙΚΗ ΣΥΝΑΡΤΗΣΗ","Φυσικές Επιστήμες","Natural Sciences","Φυσική","Physical Sciences"],"dc:title":["ΠΡΟΣΕΓΓΙΣΤΙΚΕΣ ΜΕΘΟΔΟΙ ΜΕΛΕΤΗΣ ΚΛΕΙΣΤΟΥ ΣΥΣΤΗΜΑΤΟΣ DC-AC ΜΕΤΑΤΡΟΠΕΑ ΓΙΑ ΤΟΝ ΕΛΕΓΧΟ ΡΕΥΜΑΤΟΣ ΣΕ ΣΥΝΘΕΤΑ ΦΟΡΤΙΑ","APPROXIMATIVE METHODS OF A CLOSED-LOOP DC-AC INVERTER SYSTEM'S STUDY FOR CURRENT CONTROL IN COMPOUND LOADS"],"dc:type":["PhD Thesis"]},"updated_at":"2026-11-18T20:21:16Z"}