{"id":{"repo_id":"greece","oai_identifier":"oai:10442/23508"},"canonical_url":"https://search.ndltd.org/etd/greece/oai:10442/23508","repository":{"repo_id":"greece","name":"Greek National Archive of PhD Theses","base_url":"https://phdtheses.ekt.gr/eadd_oai/request"},"display":{"title":"Θερμοκρασιακές αλλαγές στον υποκείμενο οστίτη ιστό κατά την διαδικασία της χαλινεκτομής και εκβάθυνσης της ουλοπαρειακής αύλακος με διοδικό (diode 980 nm) laser: πειραματική μελέτη","abstract":"In this project we tried to see the temperature fluctuations in the subperiostal bone during frenectomies with diode 980 nm Laser. We used 70 front parts from sheep jaws with preserved frenulum. These 70 parts were divided in 7 groups with 10 parts in each group. In every part we made a frenectomy with diode Laser 980 nm with three different power settings (3, 4, 5 Watt) and two different emission modes, Continuous wave (CW) and Chopped mode. For better control in our results we used for the frenectomies in one of the groups an electrotom. For the measurements of the temperature fluctuations we used thermocouples with their electrodes being inserted in the subperiostal bone in equal distance (5 mm) to each other in the vertical dimension. The results have been statistically analyzed and have shown that the frenectomies with the diode 980 nm Laser gave no danger for thermal bone necrosis for power ?4 Watt while the danger during the use of electrotom and the Continuous wave diode Laser of 980 nm in 5 watt was very high","abstract_html":"In this project we tried to see the temperature fluctuations in the subperiostal bone during frenectomies with diode 980 nm Laser. We used 70 front parts from sheep jaws with preserved frenulum. These 70 parts were divided in 7 groups with 10 parts in each group. In every part we made a frenectomy with diode Laser 980 nm with three different power settings (3, 4, 5 Watt) and two different emission modes, Continuous wave (CW) and Chopped mode. For better control in our results we used for the frenectomies in one of the groups an electrotom. For the measurements of the temperature fluctuations we used thermocouples with their electrodes being inserted in the subperiostal bone in equal distance (5 mm) to each other in the vertical dimension. The results have been statistically analyzed and have shown that the frenectomies with the diode 980 nm Laser gave no danger for thermal bone necrosis for power ?4 Watt while the danger during the use of electrotom and the Continuous wave diode Laser of 980 nm in 5 watt was very high","abstract_has_math":false,"creators":["Μάνος, Αναστάσιος"],"institution":"Aristotle University Of Thessaloniki (AUTH)","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010","date_published":"2010","updated_at":"2026-11-18T20:42:31Z","subjects":["Διοδικό laser","Ηλεκτροτόμος","Οστίτης ιστός, Υποπεριοστικός","Χαλινεκτομή","Θερμοκρασία","Χρόνος ακτινοβόλησης","Χρόνος ψύξης","Θερμοστοιχεία","Diode laser","Electrotome","Bone tissue, Subperiostal","Frenestomy","Temperature","Irradiation time","Cooling time","Thermocouples","Ιατρική και Επιστήμες Υγείας","Κλινική Ιατρική","Medical and Health Sciences","Clinical Medicine"],"languages":["gre"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/23508"],"render_values":[{"text":"10.12681/eadd/23508","href":"https://doi.org/10.12681/eadd/23508","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10442/hedi/23508","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/10442/hedi/23508","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://phdtheses.ekt.gr/eadd_oai/request?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3A10442%2F23508","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Μάνος, Αναστάσιος"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010"]},{"key":"dc:publisher","label":"Institution","values":["Aristotle University Of Thessaloniki (AUTH)","Αριστοτέλειο Πανεπιστήμιο Θεσσαλονίκης (ΑΠΘ)"]},{"key":"dc:type","label":"Dc Type","values":["PhD Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Διοδικό laser","Ηλεκτροτόμος","Οστίτης ιστός, Υποπεριοστικός","Χαλινεκτομή","Θερμοκρασία","Χρόνος ακτινοβόλησης","Χρόνος ψύξης","Θερμοστοιχεία","Diode laser","Electrotome","Bone tissue, Subperiostal","Frenestomy","Temperature","Irradiation time","Cooling time","Thermocouples","Ιατρική και Επιστήμες Υγείας","Κλινική Ιατρική","Medical and Health Sciences","Clinical Medicine"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["gre"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/23508","http://hdl.handle.net/10442/hedi/23508"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["In this project we tried to see the temperature fluctuations in the subperiostal bone during frenectomies with diode 980 nm Laser. We used 70 front parts from sheep jaws with preserved frenulum. These 70 parts were divided in 7 groups with 10 parts in each group. In every part we made a frenectomy with diode Laser 980 nm with three different power settings (3, 4, 5 Watt) and two different emission modes, Continuous wave (CW) and Chopped mode. For better control in our results we used for the frenectomies in one of the groups an electrotom. For the measurements of the temperature fluctuations we used thermocouples with their electrodes being inserted in the subperiostal bone in equal distance (5 mm) to each other in the vertical dimension. The results have been statistically analyzed and have shown that the frenectomies with the diode 980 nm Laser gave no danger for thermal bone necrosis for power ?4 Watt while the danger during the use of electrotom and the Continuous wave diode Laser of 980 nm in 5 watt was very high","Για να ερευνήσουμε τις θερμοκρασιακές μεταβολές στο υποπεριοστικό οστό κατά την διαδικασία της χαλινεκτομής με διοδικό Laser (diode 980 nm) χρησιμοποιήσαμε 70 κάτω γνάθους σφαγιασμένων προβάτων με διατηρημένο τον χαλινό. Αυτές διαχωρίστηκαν σε 7 ομάδες των 10 γνάθων η κάθε μία. Σε κάθε γνάθο έγινε χαλινεκτομή με διοδικό Laser (diode 980 nm) με την χρήση τριών διαφορετικών παραμέτρων (3, 4, 5 Watt) και δύο διαφορετικών τύπων εκπομπής κύματος του Laser (συνεχούς και διακεκομμένου). Για να υπάρχει σύγκριση με μία παλαιότερη τεχνική χαλινεκτομής, σε μία ομάδα έγιναν χαλινεκτομές με ηλεκτροτόμο. Για την μέτρηση των διαφορών της θερμοκρασίας χρησιμοποιήθηκαν θερμοστοιχεία τα ηλεκτρόδια των οποίων εισήχθησαν στον υποπεριοστικό ιστό σε απόσταση 5 mm μεταξύ τους κατά την κάθετη διάσταση του οστού. Τα αποτελέσματα αναλύθηκαν στατιστικώς και έδειξαν ότι στις χαλινεκτομές με διοδικό (diode 980 nm) ? 4 W δεν υπήρξε κίνδυνος θερμικής νέκρωσης του υποπεριοστικού οστού ενώ στις χαλινεκτομές με ηλεκτροτόμο και διοδικό Laser 980 nm συνεχούς τύπου εκπομπής κύματος ο κίνδυνος ήταν μεγαλύτερος"]},{"key":"dc:title","label":"Title","values":["Θερμοκρασιακές αλλαγές στον υποκείμενο οστίτη ιστό κατά την διαδικασία της χαλινεκτομής και εκβάθυνσης της ουλοπαρειακής αύλακος με διοδικό (diode 980 nm) laser: πειραματική μελέτη","Temperature changes in subperiostal bone tissue during frenectomy - vestibuloplasty procedures with a Diode 980 nm laser: an experimental study"]}]}],"canonical_facts":{"dc:creator":["Μάνος, Αναστάσιος"],"dc:date":["2010"],"dc:description":["In this project we tried to see the temperature fluctuations in the subperiostal bone during frenectomies with diode 980 nm Laser. We used 70 front parts from sheep jaws with preserved frenulum. These 70 parts were divided in 7 groups with 10 parts in each group. In every part we made a frenectomy with diode Laser 980 nm with three different power settings (3, 4, 5 Watt) and two different emission modes, Continuous wave (CW) and Chopped mode. For better control in our results we used for the frenectomies in one of the groups an electrotom. For the measurements of the temperature fluctuations we used thermocouples with their electrodes being inserted in the subperiostal bone in equal distance (5 mm) to each other in the vertical dimension. The results have been statistically analyzed and have shown that the frenectomies with the diode 980 nm Laser gave no danger for thermal bone necrosis for power ?4 Watt while the danger during the use of electrotom and the Continuous wave diode Laser of 980 nm in 5 watt was very high","Για να ερευνήσουμε τις θερμοκρασιακές μεταβολές στο υποπεριοστικό οστό κατά την διαδικασία της χαλινεκτομής με διοδικό Laser (diode 980 nm) χρησιμοποιήσαμε 70 κάτω γνάθους σφαγιασμένων προβάτων με διατηρημένο τον χαλινό. Αυτές διαχωρίστηκαν σε 7 ομάδες των 10 γνάθων η κάθε μία. Σε κάθε γνάθο έγινε χαλινεκτομή με διοδικό Laser (diode 980 nm) με την χρήση τριών διαφορετικών παραμέτρων (3, 4, 5 Watt) και δύο διαφορετικών τύπων εκπομπής κύματος του Laser (συνεχούς και διακεκομμένου). Για να υπάρχει σύγκριση με μία παλαιότερη τεχνική χαλινεκτομής, σε μία ομάδα έγιναν χαλινεκτομές με ηλεκτροτόμο. Για την μέτρηση των διαφορών της θερμοκρασίας χρησιμοποιήθηκαν θερμοστοιχεία τα ηλεκτρόδια των οποίων εισήχθησαν στον υποπεριοστικό ιστό σε απόσταση 5 mm μεταξύ τους κατά την κάθετη διάσταση του οστού. Τα αποτελέσματα αναλύθηκαν στατιστικώς και έδειξαν ότι στις χαλινεκτομές με διοδικό (diode 980 nm) ? 4 W δεν υπήρξε κίνδυνος θερμικής νέκρωσης του υποπεριοστικού οστού ενώ στις χαλινεκτομές με ηλεκτροτόμο και διοδικό Laser 980 nm συνεχούς τύπου εκπομπής κύματος ο κίνδυνος ήταν μεγαλύτερος"],"dc:identifier":["10.12681/eadd/23508","http://hdl.handle.net/10442/hedi/23508"],"dc:language":["gre"],"dc:publisher":["Aristotle University Of Thessaloniki (AUTH)","Αριστοτέλειο Πανεπιστήμιο Θεσσαλονίκης (ΑΠΘ)"],"dc:subject":["Διοδικό laser","Ηλεκτροτόμος","Οστίτης ιστός, Υποπεριοστικός","Χαλινεκτομή","Θερμοκρασία","Χρόνος ακτινοβόλησης","Χρόνος ψύξης","Θερμοστοιχεία","Diode laser","Electrotome","Bone tissue, Subperiostal","Frenestomy","Temperature","Irradiation time","Cooling time","Thermocouples","Ιατρική και Επιστήμες Υγείας","Κλινική Ιατρική","Medical and Health Sciences","Clinical Medicine"],"dc:title":["Θερμοκρασιακές αλλαγές στον υποκείμενο οστίτη ιστό κατά την διαδικασία της χαλινεκτομής και εκβάθυνσης της ουλοπαρειακής αύλακος με διοδικό (diode 980 nm) laser: πειραματική μελέτη","Temperature changes in subperiostal bone tissue during frenectomy - vestibuloplasty procedures with a Diode 980 nm laser: an experimental study"],"dc:type":["PhD Thesis"]},"updated_at":"2026-11-18T20:42:31Z"}