{"id":{"repo_id":"greece","oai_identifier":"oai:10442/24121"},"canonical_url":"https://search.ndltd.org/etd/greece/oai:10442/24121","repository":{"repo_id":"greece","name":"Greek National Archive of PhD Theses","base_url":"https://phdtheses.ekt.gr/eadd_oai/request"},"display":{"title":"Η συμβολή της περιμετρίας βραχέως μήκους κύματος (SWAP) και του αναλυτή των νευρικών ινών (SLP) στην μελέτη της οφθαλμικής υπερτονίας","abstract":"Aims: To compare and correlate retinal nerve fiber layer (RNFL) measurements obtained by Scanning Laser Polarimetry (SLP) with defects detected by short wavelength automatic perimetry (SWAP) in eyes with ocular hypertension (OHT). Methods: Scanning Laser polarimetry and SWAP was performed in ninety-six eyes of 48 consecutive patients with OHT. Results: Twenty-five eyes (26%) had SWAP visual field defects. Twenty-seven eyes (28.1%) had abnormal RNFL evaluation defined by the GDx neural network (“number“>29). Fourteen eyes of ten patients (14.5%) had abnormal RNFL evaluation and SWAP visual field defects. Retinal nerve fiber layer thickness measurements were significantly reduced in eyes with abnormal SWAP. A weak but statistically significant correlation between the “number” the Pattern Standard Deviation (r = 0.3 p = 0.006) and the Corrected Pattern Standard Deviation (r = 0.3 p = 0.007) in SWAP was found. Areas of abnormal RNFL thickness corresponded to the localization of the SWAP visual field defects in corrected pattern deviation plots in 10 of the 14 eyes with defects in both tests. Conclusions: SWAP visual field defects frequently coexist and correspond with abnormalities of RNFL detected by SLP in eyes with OHT. In certain eyes however, the two methods detect different glaucoma properties.","abstract_html":"Aims: To compare and correlate retinal nerve fiber layer (RNFL) measurements obtained by Scanning Laser Polarimetry (SLP) with defects detected by short wavelength automatic perimetry (SWAP) in eyes with ocular hypertension (OHT). Methods: Scanning Laser polarimetry and SWAP was performed in ninety-six eyes of 48 consecutive patients with OHT. Results: Twenty-five eyes (26%) had SWAP visual field defects. Twenty-seven eyes (28.1%) had abnormal RNFL evaluation defined by the GDx neural network (“number“&gt;29). Fourteen eyes of ten patients (14.5%) had abnormal RNFL evaluation and SWAP visual field defects. Retinal nerve fiber layer thickness measurements were significantly reduced in eyes with abnormal SWAP. A weak but statistically significant correlation between the “number” the Pattern Standard Deviation (r = 0.3 p = 0.006) and the Corrected Pattern Standard Deviation (r = 0.3 p = 0.007) in SWAP was found. Areas of abnormal RNFL thickness corresponded to the localization of the SWAP visual field defects in corrected pattern deviation plots in 10 of the 14 eyes with defects in both tests. Conclusions: SWAP visual field defects frequently coexist and correspond with abnormalities of RNFL detected by SLP in eyes with OHT. In certain eyes however, the two methods detect different glaucoma properties.","abstract_has_math":false,"creators":["Halkiadakis, Ioannis","Χαλκιαδάκης, Ιωάννης"],"institution":"National and Kapodistrian University of Athens","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007","date_published":"2007","updated_at":"2026-11-18T20:43:06Z","subjects":["Περιμετρία","Αναλυτής νευρικών ινών","Γλαύκωμα","Υπερτονία","Γαγγλιακά κύτταρα","Perimetry","Nerve fiber analyzer","Glaukoma","Ocular hypertension","Gagglion cells","Ιατρική και Επιστήμες Υγείας","Κλινική Ιατρική","Medical and Health Sciences","Clinical Medicine"],"languages":["gre"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/24121"],"render_values":[{"text":"10.12681/eadd/24121","href":"https://doi.org/10.12681/eadd/24121","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10442/hedi/24121","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/10442/hedi/24121","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://phdtheses.ekt.gr/eadd_oai/request?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3A10442%2F24121","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Halkiadakis, Ioannis","Χαλκιαδάκης, Ιωάννης"]},{"key":"dc:creator.fathername","label":"Dc Creator Fathername","values":["Stergios"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2007"]},{"key":"dc:publisher","label":"Institution","values":["National and Kapodistrian University of Athens","Εθνικό και Καποδιστριακό Πανεπιστήμιο Αθηνών (ΕΚΠΑ)"]},{"key":"dc:type","label":"Dc Type","values":["PhD Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Περιμετρία","Αναλυτής νευρικών ινών","Γλαύκωμα","Υπερτονία","Γαγγλιακά κύτταρα","Perimetry","Nerve fiber analyzer","Glaukoma","Ocular hypertension","Gagglion cells","Ιατρική και Επιστήμες Υγείας","Κλινική Ιατρική","Medical and Health Sciences","Clinical Medicine"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["gre"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["10.12681/eadd/24121","http://hdl.handle.net/10442/hedi/24121"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Aims: To compare and correlate retinal nerve fiber layer (RNFL) measurements obtained by Scanning Laser Polarimetry (SLP) with defects detected by short wavelength automatic perimetry (SWAP) in eyes with ocular hypertension (OHT). Methods: Scanning Laser polarimetry and SWAP was performed in ninety-six eyes of 48 consecutive patients with OHT. Results: Twenty-five eyes (26%) had SWAP visual field defects. Twenty-seven eyes (28.1%) had abnormal RNFL evaluation defined by the GDx neural network (“number“>29). Fourteen eyes of ten patients (14.5%) had abnormal RNFL evaluation and SWAP visual field defects. Retinal nerve fiber layer thickness measurements were significantly reduced in eyes with abnormal SWAP. A weak but statistically significant correlation between the “number” the Pattern Standard Deviation (r = 0.3 p = 0.006) and the Corrected Pattern Standard Deviation (r = 0.3 p = 0.007) in SWAP was found. Areas of abnormal RNFL thickness corresponded to the localization of the SWAP visual field defects in corrected pattern deviation plots in 10 of the 14 eyes with defects in both tests. Conclusions: SWAP visual field defects frequently coexist and correspond with abnormalities of RNFL detected by SLP in eyes with OHT. In certain eyes however, the two methods detect different glaucoma properties.","Σκοπός: Η συσχέτιση του πάχους των νευρικών ινών όπως αυτό μετράται με την Scanning Laser Polarimetry (SLP) με τα σκοτώματα στην short wavelength automatic perimetry (SWAP) σε μάτια με οφθαλμική υπερτονία. Μέθοδος: Scanning Laser polarimetry και SWAP πραγματοποιήθηκαν σε ενενήντα-έξη μάτια 48 διαδοχικών ασθενών με οφθαλμική υπερτονία. Αποτελέσματα: Εικοσιπέντε μάτια (26%) είχαν σκοτώματα στην SWAP. Είκοσι επτά μάτια (28.1%) είχαν παθολογική εξέταση νευρικών ινών SLP όταν με κριτήριο την παράμετρο “number“>29. Δεκατέσσερα μάτια δέκα ασθενών (14.5%) είχαν παθολογική SLP και σκοτώματα στην SWAP. Το πάχος των νευρικών ινών ήταν ελαττωμένο σε ασθενείς με σκοτώματα στην SWAP. Μια ασθενής αλλά στατιστικά σημαντική συσχέτιση ανευρέθη ανάμεσα στην παράμετρο “number” της SLP και την Pattern Standard Deviation (r = 0.3 p = 0.006) και Corrected Pattern Standard Deviation (r = 0.3 p = 0.007) στην SWAP. Υπήρχε καλή αντιστοίχιση ανάμεσα στις περιοχές με την ελάττωση του πάχους των νευρικών ινών και τα σκοτώματα στην SWAP σε 10 από 14 μάτια με ελλείμματα και στις δυο εξετάσεις. Συμπεράσματα: Τα σκοτώματα στην SWAP πολλές φορές συνυπάρχουν και έχουν κοινή εντόπιση με τα ελλείμματα των νευρικών ινών στην SLP σε μάτια με οφθαλμική υπερτονία. Σε ορισμένα μάτια οι δυο μέθοδοι δίνουν διαφορετικά αποτελέσματα."]},{"key":"dc:title","label":"Title","values":["Η συμβολή της περιμετρίας βραχέως μήκους κύματος (SWAP) και του αναλυτή των νευρικών ινών (SLP) στην μελέτη της οφθαλμικής υπερτονίας","Study of ocular hypertension with short wavelength automatic perimetry and scanning laser polarimetry"]}]}],"canonical_facts":{"dc:creator":["Halkiadakis, Ioannis","Χαλκιαδάκης, Ιωάννης"],"dc:creator.fathername":["Stergios"],"dc:date":["2007"],"dc:description":["Aims: To compare and correlate retinal nerve fiber layer (RNFL) measurements obtained by Scanning Laser Polarimetry (SLP) with defects detected by short wavelength automatic perimetry (SWAP) in eyes with ocular hypertension (OHT). Methods: Scanning Laser polarimetry and SWAP was performed in ninety-six eyes of 48 consecutive patients with OHT. Results: Twenty-five eyes (26%) had SWAP visual field defects. Twenty-seven eyes (28.1%) had abnormal RNFL evaluation defined by the GDx neural network (“number“>29). Fourteen eyes of ten patients (14.5%) had abnormal RNFL evaluation and SWAP visual field defects. Retinal nerve fiber layer thickness measurements were significantly reduced in eyes with abnormal SWAP. A weak but statistically significant correlation between the “number” the Pattern Standard Deviation (r = 0.3 p = 0.006) and the Corrected Pattern Standard Deviation (r = 0.3 p = 0.007) in SWAP was found. Areas of abnormal RNFL thickness corresponded to the localization of the SWAP visual field defects in corrected pattern deviation plots in 10 of the 14 eyes with defects in both tests. Conclusions: SWAP visual field defects frequently coexist and correspond with abnormalities of RNFL detected by SLP in eyes with OHT. In certain eyes however, the two methods detect different glaucoma properties.","Σκοπός: Η συσχέτιση του πάχους των νευρικών ινών όπως αυτό μετράται με την Scanning Laser Polarimetry (SLP) με τα σκοτώματα στην short wavelength automatic perimetry (SWAP) σε μάτια με οφθαλμική υπερτονία. Μέθοδος: Scanning Laser polarimetry και SWAP πραγματοποιήθηκαν σε ενενήντα-έξη μάτια 48 διαδοχικών ασθενών με οφθαλμική υπερτονία. Αποτελέσματα: Εικοσιπέντε μάτια (26%) είχαν σκοτώματα στην SWAP. Είκοσι επτά μάτια (28.1%) είχαν παθολογική εξέταση νευρικών ινών SLP όταν με κριτήριο την παράμετρο “number“>29. Δεκατέσσερα μάτια δέκα ασθενών (14.5%) είχαν παθολογική SLP και σκοτώματα στην SWAP. Το πάχος των νευρικών ινών ήταν ελαττωμένο σε ασθενείς με σκοτώματα στην SWAP. Μια ασθενής αλλά στατιστικά σημαντική συσχέτιση ανευρέθη ανάμεσα στην παράμετρο “number” της SLP και την Pattern Standard Deviation (r = 0.3 p = 0.006) και Corrected Pattern Standard Deviation (r = 0.3 p = 0.007) στην SWAP. Υπήρχε καλή αντιστοίχιση ανάμεσα στις περιοχές με την ελάττωση του πάχους των νευρικών ινών και τα σκοτώματα στην SWAP σε 10 από 14 μάτια με ελλείμματα και στις δυο εξετάσεις. Συμπεράσματα: Τα σκοτώματα στην SWAP πολλές φορές συνυπάρχουν και έχουν κοινή εντόπιση με τα ελλείμματα των νευρικών ινών στην SLP σε μάτια με οφθαλμική υπερτονία. Σε ορισμένα μάτια οι δυο μέθοδοι δίνουν διαφορετικά αποτελέσματα."],"dc:identifier":["10.12681/eadd/24121","http://hdl.handle.net/10442/hedi/24121"],"dc:language":["gre"],"dc:publisher":["National and Kapodistrian University of Athens","Εθνικό και Καποδιστριακό Πανεπιστήμιο Αθηνών (ΕΚΠΑ)"],"dc:subject":["Περιμετρία","Αναλυτής νευρικών ινών","Γλαύκωμα","Υπερτονία","Γαγγλιακά κύτταρα","Perimetry","Nerve fiber analyzer","Glaukoma","Ocular hypertension","Gagglion cells","Ιατρική και Επιστήμες Υγείας","Κλινική Ιατρική","Medical and Health Sciences","Clinical Medicine"],"dc:title":["Η συμβολή της περιμετρίας βραχέως μήκους κύματος (SWAP) και του αναλυτή των νευρικών ινών (SLP) στην μελέτη της οφθαλμικής υπερτονίας","Study of ocular hypertension with short wavelength automatic perimetry and scanning laser polarimetry"],"dc:type":["PhD Thesis"]},"updated_at":"2026-11-18T20:43:06Z"}